SECTION 47 1 FIBER REINFORCED POLYMER FENDER SYSTEM S
471-1 Description.
Construct fiber reinforced polymer (FRP) fender systems using components in accordance with this Section and the Plans. Submit a design for the FRP fender system in accordance with 471-4.2.
471-2 Materials.
Meet the following requirements: Fiber reinforced polymer composite s (Piles, Wales, Spacer-blocks, Decking & Splice Plates ) ................................ .............. Section 973 Concrete used to fill hollow piles ................................ . Section 347 Use only SAE Type 316 stainless steel metallic fastening and connection hardware.
471-3 Product Acceptance.
Obtain fender system components from a producer that is currently on the list of Producers with Accepted Quality Control Program for Fiber Reinforced P olymer Composites. Producers seeking inclusion on the list shall meet the requirements of 105 -3. Submit to the Engineer the manufacturer’s certification in accordance with Section 6 that the fender system components meet the material requirements of Secti on 973.
471-4 Shop Drawings and Design Calculations.
471-4.1 Shop Drawings: Submit shop drawings in accordance with Section 5. Include
the following , as a minimum, in the shop drawings:
471-4.2 Design Calculations: Design fender piling, wales and connections in accordance
with the latest edition of the FDOT Structures Design Guidelines (SDG) and the FDOT Structures Detailing Manual based on the desired energy capacity rating. Design calculations FY 2023-24 Return to Table of Contents may be either by hand or by a computer program w ith hand calculations verifying the program output. Submit the following design information:
471-5 Design Criteria.
471-5.1 Wales: Wales must meet the following minimum design criteria:
471-5.2 Piles: Piles must meet the following minimum design criteria:
471-6 Storage, Handling and Installation .
Unless otherwise shown in the manufacturer’s approved field construction manual, use the following construction details. Protect materials at all times against exposure to extreme he at or impact. Transport products in a manner that will minimize scratching or damage to the outer surfaces, stack on dunnage above ground so that it may be easily inspected and store in a manner that will avoid damage. Handle and lift products with nylon s lings. Do not use sharp instruments in handling the product. Products damaged in shipping or handling will be rejected. Products containing cracks in the reinforcing rods , or cracks or splits (partial or full depth) across the section will be rejected. Cut, bevel, drill, countersink and otherwise install products in accordance with the manufacturer’s recommendations. Set all material accurately to required levels and lines, with members plumb and true and accurately cut and fitted. Securely attach all mat erials to substrate by anchoring and fastening as shown in the shop drawings . Perform all cutting and drilling in a manner that allows for the collection of all debris and dispose of properly. Install piles in accordance with Section 455.
471-7 Method of Measurement.
The quantity for the entire fender system to be paid will be lump sum.
471-8 Basis of Payment.
471-8.1 Price and payment for fender system will be full compensation for the work
specified in this Section including all labor, equipment and ma terials required to furnish and install the piles to the pile cut -off elevations shown in the Plans, and all wales, dimensional lumber, material, storage costs, disposal of unused material and waste, transportation costs, fasteners and other necessary item s required for completing the work. Payment will be made under: Item No. 471 - 3- Fender System Polymeric - lump sum . FY 2023-24 Return to Table of Contents INCIDENTAL CONSTRUCTION SECTION 502 SHEAR CONNECTORS
502-1 Description.
Furnish and install welded shear connectors on steel beams and girders at locations shown in the Contract Documents. Field weld shear connectors located on the top flange only after the deck forms are in place. Installation of shear connectors in the fabrication plant is not permitted.
502-2 General Requirements.
502-2.1 Design: Provide shear connector studs of a design suitable for end -welding to
steel beams and girders, with automatically timed stud welding equipment. Provide the type, size or diameter, and length of stud as specified by the Contract Documents, and as approved by the Engineer. Meet the allowable tolerances on dimensions as specified in 502 -7.
502-2.2 Arc-Shield: Furnish an arc -shield (ferrule), of heat -resistant ceramic or other
suitable material, with each stud. Use material that is not detrimental to the welds, does not cause excessive slag, and has sufficient strength not to crumble or break due to thermal or structure shock before the weld is completed.
502-2.3 Flux: Furnish flux for welding with each stud, either attached to the end of the
stud or combined with the arc -shield for automatic application in the welding operation.
502-2.4 Coatings: Do not pa int or galvanize studs.
502-2.5 Qualification: Use only qualified studs, passing the tests prescribed in 502 -6.
Use the same arc -shield in production as used in the qualification tests.
502-2.6 Data to be Submitted: Before placing orders for studs, submi t to the Engineer
for approval, the following information on the studs to be purchased:
502-2 5.
502-2.7 Freedom from Defects: After welding, ensure that the studs are free from any
defect or substance that would interfere with their function as shear connectors.
502-3 Materials.
502-3.1 Metal: For shear connector studs, meet the requirements of ASTM A108, cold -
drawn bar, Grades 1015, 1017, or 1020, either semi -killed or fully -killed. If using flux -retaining caps, use caps of a low -carbon grad e steel suitable for welding and meeting the requirements of ASTM A109.
502-3.2 Mechanical Properties: For tensile properties as determined by tests of bar
stock after drawing, or of finished studs, meet the following requirements: Tensile strength ................................ .. 60,000 psi (minimum) Yield strength* ................................ ... 50,000 psi (minimum) Elongation ................................ . 20% in 2 inches (minimum) FY 2023-24 Return to Table of Contents