806.1 General Description

This section includes the requirements for aggregate used for drainage.

806.1.01 Related References

A. Standard Specifications Section 800 – Coarse Aggregate B. Referenced Documents AASHTO T 11 AASHTO T 27 GDT 4

806.2 Materials

806.2.01 Coarse Aggregate for Underdrains

A. Requirements Use Class A or B coarse aggregate graded for size No. 89 in Table 800.1 B. Fabrication General Provisions 101 through 150. C. Acceptance Test the aggregate as follows: Test Method Sieve analysis AASHTO T 27 D. Materials Warranty General Provisions 101 through 150.

806.2.02 Crushed Stone Drainage Material

A. Requirements Use Class A or B coarse aggregate that is graded as follows: Sieve Size Percent by Weight Passing 2 in. (50 mm) 100 Passing 1-1/2 in. (37.5 mm) 95-100 Passing No. 10 (2 mm) 10-35 Passing No. 100 (150 µm) 0-10 B. Fabrication General Provisions 101 through 150. C. Acceptance Test the crushed stone as follows: Test Method Sieve analysis AASHTO T 27 D. Materials Warranty General Provisions 101 through 150.

806.2.03 Drainage Blanket

A. Requirements Use Class A or B coarse aggregate that is graded as follows: Sieve Size Percent by Weight Passing No. 10 (2 mm) 75-100 Passing No. 40 (425 µm) 25-50 Passing No. 60 (250 µm) 0-25 Passing No. 200 (75 µm) 0-8 Percent clay 0-5 B. Fabrication General Provisions 101 through 150. C. Acceptance Test the aggregate as follows: Test Method Sieve analysis AASHTO T 11 and AASHTO T 27 Percent clay (8-minute elutriation test) GDT 4 D. Material Warranty General Provisions 101 through 150.

Aggregate for Drainage in other states

Get an email when 806 changes

Georgia revises spec sections through supplementals and new editions. We check this one every week and email you the day it changes. Free, no account.

Source: Standard Specifications for Construction of Transportation Systems, 2021 Edition. Pages 1475–1476 of 2,050. View official source ↗

Ask about this section

Scoped to Georgia 2021 Standard Specifications, Section 806 — Aggregate for Drainage. Every answer cites the section it came from, with a verification date — don’t trust a percentage, click the citation.