B
HomeLibrariesCode AISearchProjectsBookmarksAddress
FeedbackHelp Desk
Libraries
Code LibraryDiagramsAssembliesProductsCalculatorsChecklistsCSI MasterFormat SpecificationsPermitsAddress ReportDOT SpecsModel CodesTransportationRailroadFire SafetyAccessibilityStructuralTransit SpecsUSACE
PricingLog in
Division 41 — Construction Materials

4102Water for Concrete and Mortar

IA · 2023 Standard SpecificationsBook pages 10721072View official source ↗

4102.01

GENERAL REQUIREMENTS.

A.

Use water for concrete or mortar that is free from detrimental amounts of oil, salts, acids, alkali, organic matter, or other objectionable substances. Do not use recycled wash water in concrete.

B.

Where the source of water is relatively shallow, maintain it at a suitable depth and screen the intake to exclude objectionable amounts of silt, mud, grass, or other foreign material. Filter, or otherwise clarify, water containing suspended matter in excess of 2000 ppm.

C.

Use water meeting the following quality requirements:

D.

1.

Hardness, determined as calcium carbonate, not more than 750 ppm.

2.

Methyl Orange, Alkalinity, determined as calcium carbonate, not more than 1000 ppm.

3.

Phenolphthalein Alkalinity, determined as calcium carbonate, not more than one-half the methyl orange alkalinity.

4.

Total Acidity, determined as calcium carbonate, no more than 100 ppm.

Potable water obtained from a municipal supply, suitable for drinking, may be accepted without testing.

Source: Iowa Standard Specifications for Highway and Bridge Construction, 2023 Edition. Pages 10721072 of 1,288.

Ask about this section

Scoped to Iowa Standard Specifications for Highway and Bridge Construction, Section 4102 — Water for Concrete and Mortar. Every answer cites the section it came from, with a verification date — don’t trust a percentage, click the citation.

Iowa DOT Standard Specifications for Highway and Bridge Construction Section 4102 Water for Concrete and Mortar — Full Text | BuildSpec