Light Poles Art. 830.02 SECTION 827. TRANSFORMER, GENERAL PURPOSE
827.01 Description. This work shall consist of furnishing a dry type
transformer, wiring, conduit and mounting hardware, and installing it at the location shown on the plans or as designated by the Engineer.
827.02 Materials. Materials shall be according to the following.
Item Article/Section
827.03 Installation. General purpose transformers may be mounted inside a
control cabinet, on a sign truss, and on a bridge structure requiring different mounting hardware. All material required to complete the installation shall be included. The transformer enclosure shall be NEMA TYPE 3R or 4X and may be stainless steel as shown on the plans. It shall be solid dielectric, air cooled, and of a type (i.e., buck/boost) as specified. The plans shall identify size in KVA as well as primary and secondary voltages. Air movement must be considered for mounting inside a junction box or other confined space.
827.04 Basis of Payment. This work will be paid for at the contract unit price
per each for TRANSFORMER, GENERAL PURPOSE, of the size and type specified. POLES AND TOWERS SECTION 830. LIGHT POLES
830.01 Description. This work shall consist of furnishing and installing a light
pole complete with an arm(s), when specified, and all hardware and accessories required for the intended temporary or permanent use of the pole.
830.02 Materials. Materials shall be according to the following.
Item Article/Section
830.03 Installation. The light pole shall be set plumb on the foundation
without the use of shims, or washers for leveling. On bridge parapet walls, a vibration mounting pad shall be installed between the foundation leveling plate and the light pole. The handhole shall be located such that workers accessing the handhole shall face oncoming traffic directly or located on the back side of the pole facing the roadway. On bridge parapet walls, the access handhole shall be oriented facing the roadway. On center median barrier walls, all access handholes shall be oriented to the one side with the least traffic flow. Arms shall be set at right angles to the centerline of the pavement. Poles shall not be left in place without arm(s) and luminaire(s). The Contractor shall be responsible for furnishing pole mounting equipment that is of adequate strength and compatible for the pole it supports. This shall include, but not be limited to, the foundation, breakaway device (when specified), anchor rods, and hardware. Lighting unit identification numbers shall be installed before the lighting unit is energized.
830.04 Temporary Installation. Wood poles used for a temporary lighting
installation may be previously used poles as approved by the Engineer. The poles shall be in good condition and shall be according to the applicable ANSI requirements for sweep, crook, defects, and mechanical damage. Poles deemed unacceptable by the Engineer shall be removed from the jobsite.