1907 - PLASTIC PIPE FOR UNDERDRAINS, OUTLETS AND DRAIN TILE 1900-12
1907.1 Description
This specification covers polyvinyl chloride (PVC) pipe for use in underdrain, pavement edge drain, and outlet installations. Polyethylene (PE) is also permitted for edge drains.
1907.2 Requirements
a. Underdrain Pipe. Provide perforated polyethylene or polyvinyl chloride underdrain pipe and fittings in the diameter shown in the Contract Do cuments that complies with ASTM F 891 for polyvinyl chloride, except the minimum pipe stiffness required is 100 psi, at 5% deflection, for PVC pipe. b. Outlet Pipe . Provide a smooth interior walled pipe in the diameter shown in the Contract Documents that complies with ASTM F 891 for polyvinyl chloride, except the minimum pipe stiffness required is 100 psi, at 5% deflection, for PVC pipe. c. Drain Tile. Provide perforated polyethylene drain tile and fittings in the diameter shown in the Contract Documents that complies with AASHTO M 252 or M 294 for perforated polyethylene pipe.
1907.3 Test Methods
Test pipe supplied for this specification according to the procedures referenced and outlined in AASHTO M 252, AASHTO M 294, and ASTM F 891.
1907.4 Prequalification
None Required.
1907.5 Basis of Acceptance
Receipt and approval of a Type D certification as specified in DIVISION 2600. Visual inspection for conditions and dimensional requirements.
Get an email when 1907 changes
Kansas revises spec sections through supplementals and new editions. We check this one every week and email you the day it changes. Free, no account.