B
HomeLibrariesCode AISearchProjectsBookmarksAddress
FeedbackHelp Desk
Libraries
Estimate & calculate
CalculatorsChecklists
PricingLog in
Category 800 — Traffic

809Trenching and Backfilling

MD · 2026 Standard Specifications✓ Full text on BuildSpecBook pages 904–904 Save this section

Ask about Section 809

Get a cited answer from the section text. Click the citation to check it.

One cited answer a day is free. Start a 14-day trial for unlimited, no card required.

809 — TRENCHING AND BACKFILLING 2026 STANDARD SPECIFICATIONS FOR CONSTRUCTION AND MATERIALS CATEGORY 800 TRAFFIC SECTION 809 — TRENCHING AND BACKFILLING

809.01 Description

Excavate trenches for the installation of underground conduit, wire, or duct cable for traffic control devices.

809.02 Materials

Backfill 950.05 Conduit Detection Tape 950.11

809.03 Construction

Excavate trenches as specified. In areas where conduit or cable is trenched, place a detector tape 6 in. below the finished grade. The tape shall be red and imprinted with a continuous warning message that reads "CAUTION: ELECTRICAL LINE BURIED BELOW", repeated every 36 in. The tape shall be inductively and conductively traceable using a standard pipe and cable locating device. Cable Treatment. Bed the duct cable and direct buried wires into the special backfill material as specified. Backfill. Backfill and compact the trench as specified in 801.03.05 and restore to its original condition. Replace topsoil, reseed, and resod, where directed.

809.04 Measurement and Payment

Trenching and backfilling will not be measured but the cost will be incidental to the Contract unit price for the installation of the pertinent Conduit, Wire, or Duct Cable.

Trenching and Backfilling in other states

Get an email when 809 changes

Maryland revises spec sections through supplementals and new editions. We check this one every week and email you the day it changes. Free, no account.

Source: Standard Specifications for Construction and Materials, 2026 Edition. Pages 904–904 of 1,138. View official source ↗

Ask about this section

Scoped to Maryland Standard Specifications for Construction and Materials, Section 809 — Trenching and Backfilling. Every answer cites the section it came from, with a verification date — don’t trust a percentage, click the citation.