818 — SIGNAL STRUCTURES 2026 STANDARD SPECIFICATIONS FOR CONSTRUCTION AND MATERIALS CATEGORY 800 TRAFFIC SECTION 818 — SIGNAL STRUCTURES

818.01 Description

Pickup and install Administration furnished signal structures. The grommets and miscellaneous hardware will be furnished by the Administration.

818.02 Materials

Signal Structures Hardware Furnished by the Administration

818.03 Construction

Install the signal structure on a concrete foundation as specified in Section 801. Breakaway base support systems, when specified, shall conform to Section 821. Repair any finish on the signal structures and mounting hardware damaged during transportation and installation to match the original finish as approved by the Engineer at no additional cost to the Administration.

818.04 Measurement and Payment

818.04.01 Installation of Administration furnished signal structures will be measured and paid for

at the Contract unit price per each for the type and size specified. The payment will be full compensation for the pickup, transportation and installation of all steel poles, mast arms, twin mast arms, triple mast arms, strain poles, and pedestal poles, breakaway base support systems, and for all material, labor, equipment, tools, and incidentals necessary to complete the work.

818.04.02 Concrete foundations will be measured and paid for as specified in 801.04.