B
HomeLibrariesCode AISearchProjectsBookmarksAddress
FeedbackHelp Desk
Libraries
Estimate & calculate
CalculatorsChecklists
PricingLog in
Incidental Construction (800-899)

801Concrete Driveways

MI · 2020 Standard Specifications✓ Full text on BuildSpecBook pages 562–564 Save this section

Ask about Section 801

Get a cited answer from the section text. Click the citation to check it.

One cited answer a day is free. Start a 14-day trial for unlimited, no card required.

8-1 DIVISION 8 – INCIDENTAL CONSTRUCTION Section 801. Concrete Driveways ..................................................................... 8-3 Section 802. Concrete Curb, Gutter, and Dividers ............................................. 8-4 Section 803. Concrete Sidewalk, Curb Ramps, and Steps ................................ 8-8 Section 804. Concrete Barriers, Glare Screens, and Foundations for Light Standards and Sign Supports .......................................................................... 8-12 Section 805. Hot Mix Asphalt Curb .................................................................. 8-16 Section 806. Shared Use Paths ...................................................................... 8-18 Section 807. Guardrail, Guardrail Terminals, and Miscellaneous Posts .......... 8-22 Section 808. Fencing ....................................................................................... 8-30 Section 809. Field Office ................................................................................. 8-36 Section 810. Permanent Traffic Signs and Supports ....................................... 8-40 Section 811. Permanent Pavement Markings .................................................. 8-59 Section 812. Temporary Traffic Control for Construction Zone Operations ...... 8-76 Section 813. Slope Protection ....................................................................... 8-128 Section 814. Paved Ditches .......................................................................... 8-132 Section 815. Landscaping ............................................................................. 8-135 Section 816. Turf Establishment .................................................................... 8-143 Section 817. Reserved .................................................................................. 8-155 Section 818. Electrical ................................................................................... 8-156 Section 819. Lighting ..................................................................................... 8-173 Section 820. Traffic Signals ........................................................................... 8-185 Section 821. Preservation of Boundary Monuments ..................................... 8-210 Section 822. Shoulder and Centerline Pavement Corrugations .................... 8-217 Section 823. Water Mains ............................................................................. 8-219 Section 824. Construction Surveying and Staking ......................................... 8-232 Section 825. Sanitary Sewer Systems .......................................................... 8-243 8-2 NOTES 8-3 Section 801. Concrete Driveways

801.01 Description

This work consists of constructing reinforced or non-reinforced concrete driveways as required by the contract.

801.02 Materials

Provide materials in accordance with the following sections : Curing Compound ................................................................................. 903 Steel Reinforcement ............................................................................. 905 Joint Materials ....................................................................................... 914 Concrete, Grade 3500 ........................................................................ 1004

801.03 Construction

Construct driveways in accordance with subsection 803.03 and the MDOT Standard Plan R -29 series .

801.04 Measurement and Payment

Pay Item Pay Unit Driveway, Reinf Conc, __ inch ....................................................... Square Yard Driveway, Nonreinf Conc, __ inch .................................................. Square Yard

A.Acceptance. Conduct concrete quality control (QC) as specified in section 1002 . The Engineer will conduct quality assurance (QA) as specified in section 1003. The Department will apply adjustments to this work based on the QA results.
B.Driveway, Reinf Conc and Driveway, Nonreinf Conc. The Engineer will measure Driveway, Reinf Conc , __ inch and Driveway, Nonreinf Conc , __ inch by the width and length placed, for the specified thickness required on the plans.

Get an email when 801 changes

Michigan revises spec sections through supplementals and new editions. We check this one every week and email you the day it changes. Free, no account.

Source: Michigan Standard Specifications for Construction, 2020 Edition. Pages 562–564 of 1,146. View official source ↗

Ask about this section

Scoped to Michigan 2020 Standard Specifications for Construction, Section 801 — Concrete Driveways. Every answer cites the section it came from, with a verification date — don’t trust a percentage, click the citation.