B
HomeLibrariesCode AISearchProjectsBookmarksAddress
FeedbackHelp Desk
Libraries
Estimate & calculate
CalculatorsChecklists
PricingLog in
Division 700 — Structures

732Flared End Sections

MO · 2026 (Oct) Standard Specifications✓ Full text on BuildSpecBook pages 492–493 Save this section

Ask about Section 732

Get a cited answer from the section text. Click the citation to check it.

One cited answer a day is free. Start a 14-day trial for unlimited, no card required.

732.1 Description. This work shall consist of furnishing and installing precast concrete or metal flared end

sections of the size and shape shown on the plans.

732.1.1 Precast concrete flared end sections shall be used with concrete or vitrified clay culvert pipe.

732.1.2 End sections for thermoplastic pipe may be either precast concrete or metal flared end sections. When

Group A Pipe is specified, aluminum coated metal or concrete flared end sections shall be used.

732.1.3 Safety slope end sections may be used with concrete, thermoplastic, or metal culvert pipe.

732.1.4 A tapered sleeve may be required to join an end section to a run of pipe as outlined in the standard plans.

732.1.5 At the option of the contractor and at no cost to the Commission, the contractor may use a tapered sleeve

to join thermoplastic pipe to flared end sections when not required by the plans.

732.1.6 At the option of the contractor and at no cost to the Commission, the contractor may use a one size

larger flared end section when joining to thermoplastic pipe to aid fitment.

732.2 Material.

732.2.1 All material shall be in accordance with Division 1000, Material Details, and specifically as follows:

Item Section/Specification Metal Flared End Sections 1020 Precast Concrete Flared End Sections 1032 Plastic Joint Compound for Vitrified Clay and Concrete Pipe 1057 Tubular Joint Seal 1057 Mortar for Pipe Joints 1066 Safety Bars and Longitudinal Bars ASTM A 53, Schedule 40 Bar Grate ASTM A 575, Grade 1020

732.2.2 Cast-in-place toe walls for precast concrete flared end sections shall be constructed of Class B or B-1

concrete, or concrete of a commercial mixture in accordance with Sec 501. Material, proportioning, air entraining, mixing, slump and transporting of Portland cement concrete shall be in accordance with Sec 501. Air-entrained concrete will not be required. Concrete shall be placed and cured in accordance with Sec 703. Precast toe walls shall be constructed of any of the above specified concrete mixtures or these walls may be constructed of the same mixture used to fabricate the precast concrete flared end sections. Precast toe walls may be cured in accordance with Sec 703 or in the same manner as the flared end sections.

732.3 Construction Requirements.

732.3.1 Flared end sections shall be joined to pipes or pipe-arches as shown on the plans and shall be placed to

the line and grade of the structure on a uniformly firm soil foundation shaped to fit the lower part of the end section.

732.3.1 1 Precast Concrete Flared End Sections. The joint material between the end section and the adjoining

pipe shall be the same as that used for the pipe joints, and shall be installed in the same manner. Toe walls shall be of the size and shape shown on the plans and may be precast or cast-in-place. Forming of cast-in-place toe walls will not be required.

732.3.1 2 Metal Flared End Sections. The end section shall be joined to the pipe or pipe-arch as shown on the

plans. The toe plate, if specified, shall be set in a trench or driven to the proper elevation. Care shall be taken to avoid damage to the metal.

732.3.2 Safety Slope End Section. The safety slope end section shall consist of a metal-flared end section,

safety bars, toe plate extension, if required in the contract, and any fasteners required for attachment to the culvert pipe.

732.3.2 1 Construction Requirements. Safety slope end sections shall be attached as shown on the plans and

shall be placed to the line and grade of the structure on a uniformly firm soil foundation shaped to fit the lower part of the end section.

732.3.2 2 Toe Plate Extension. The toe plate extension, if required, shall be attached to the end section as

shown on the plans.

732.3.2 3 Safety Bars. The number, size and spacing of safety bars shall be as shown on the plans. A bar grate

system, as shown on the plans, may be substituted for safety bars.

732.4 Method of Measurement. Measurement of precast concrete, plastic or metal flared end sections and

safety slope end sections will be made per each.

732.5 Basis of Payment. The accepted quantity of flared end sections and safety slope end sections, complete in

place, will be paid for at the contract unit price for each of the items included in the contract. When two different diameters of pipe are shown on the plans for a given location for Group B or Group C pipe, the contract unit price for the flared end section or safety slope end section that would be required for the larger diameter pipe will be used for payment purposes. No direct payment will be made for any excavation or bedding required for placement of an end section, toe walls or toe plates. Any damaged sections required to be replaced due to the contractor’s actions shall be at the contractor’s expense. Payment for tapered sleeves will be included in the contract unit price for pipe.

Get an email when 732 changes

Missouri revises spec sections through supplementals and new editions. We check this one every week and email you the day it changes. Free, no account.

Source: Missouri Standard Specifications for Highway Construction, 2026 (Oct) Edition. Pages 492–493 of 874. View official source ↗

Ask about this section

Scoped to Missouri Missouri Standard Specifications for Highway Construction, Section 732 — Flared End Sections. Every answer cites the section it came from, with a verification date — don’t trust a percentage, click the citation.