Section 684 Section 684 installing, final clean-up, all e quipment, labor, tools and incidentals necessary to complete the work. Slip casings, measured as prescr ibed above, will be paid for at the contract price per linear foot, which price shall be full compensation for all materials, tools, equipment, labor, and incidentals necessary to complete the work. Piling, measured as prescribed above, will be paid for at the contract price per linear foot, which price shall be full compensation for all materials, tools, equipment, labor, and incidentals necessary to complete the work. Payment will be made under: 684-A: Pole Foundations, __" Diameter - per cubic yard 684-B: Slip Casings, __" Diameter - per linear foot 684-C: Piling - per linear foot SECTION 685 - TEMPORARY LIGHTING SYSTEM
685.01 Description. In additional to the requirements set forth in Section 681, a
temporary lighting system shall consist of furnishing all materials, installing, erecting, constructing, and assembling same to ensu re a properly operating temporary lighting system in accordance with the plans and specifi cations. The work shall also include all maintenance associated with the completed lighting system, provision of service and electrical power for this system during the duration of the required lighting period, adjustment and relocation during traffic control phases and removal of the system at the completion of the required lighting period.
685.01.1 General. The Contractor shall make provisions with the serving utility company
for all construction necessa ry by the utility for power service. It will be required that initial fees be paid to the utility for installation of wi ring, transformers, cutouts, etc., before utility construction can begin. The Contractor shall be responsible for repa iring all malfunctions in the system due to equipment failure, vandalism, accidents, etc., including all parts, labor, equipment and incidentals necessary to maintain the system. The Contractor shall also be responsible for all utility company costs for removal of the service upon completion of the project at no additional costs to the State. The system shall be in fully operating condition during all hours of darkness for the duration of the required lighting period. All electrical materials and operations for co mplete and operative systems shall be as follows and hereinbefore specified. Lighting systems complete with fixtures, lamp s, poles, switches, conduits, and wiring shall be provided. The Contractor shall provide fo r power requirements and final electrical connections to all lighting systems, relocations required by traffic control phasing and removal of systems at completion of project.
685.01.2 Secondary Electrical Service. The temporary lighting service shall be 240-
Volt, 1-phase, 3-wire, 60-hertz or as noted on the plans. The Contractor shall pay all costs for electricity required by the lighting system during the duration of the project at no additional cost to the State. The system shall be metered. Meter base shall be of a type approved by serving utility company. The Contractor shall pay all cost s associated with system metering at no additional cost to the State.
685.01.3 Removal of Materials. Upon completion of the project in conjunction with
removal of the temporary roadways and traffic control devices, the Contractor shall disconnect and remove the traffic control lighting system. All materials shall be the property of the Contractor. The Contractor shall also be responsible for all costs incurred by the utility company for removal of utility company services.
685.02 Materials. Materials for temporary lighting systems shall meet the requirements
of Subsection 723.09.
685.03 Construction Requirements. All component parts of the temporary traffic
control lighting system shall be installed as shown on the plans and required by construction procedures.
685.04 Method of Measurement. Electrical cable of the type specified shall be measured
by the linear foot. Measuremen t shall be computed horizontally from terminal to terminal along the circuits. No extra lengths will be measured for risers to lighting assemblies or any other terminals. Temporary lighting assembly shall be measured as a unit quantity per each. Measurement shall include fixture, junction box, wiring, pole, ground rod, bracket, lamp and all other items necessary to complete the installation. Service pole shall be measured per each. Meas urement shall include pole, wiring, conduit, supporting devices, ground rod, hardware, safe ty switch, fuses, utility company service provisions, electrical power and all other items necessary to complete the installation.
685.05 Basis of Payment. Electrical cable, measured as prescribed above, will be paid
for at the contract unit price per linear foot , which price shall be full compensation for furnishing, installing, connecting, testing, materials, supporting devices, final clean-up, all labor, equipment, tools, and in cidentals necessary to complete the work and for removal of materials upon completion of project. Temporary lighting assembly, measured as prescr ibed above, will be paid for at the contract unit price per each, which price shall be full compensation for furnishing all materials, for excavation, back-filling, replacing sod, for all construction, placing, erecting, installing, connecting, testing, maintaining, junction boxes for poles, brackets, luminaires including lamps and ballast, ground rods, conduits, hard ware, cable, for adjustments, replacement of equipment or material which malfunctions, for final cleaning up, for all equipment, labor, tools, and incidentals necessary to complete the work, and for removal of materials upon completion of project. Service pole, measured as prescribed above, w ill be paid for at the contract unit price per each, which price shall be fu ll compensation for furnishi ng all materials for all construction, placing, erecting, installing, connecting and testing, for utility company up/down costs, electrical power, pole, safety switch, wiring, fuses, conduit, ground rod, supporting devices, all hardware, for adjustments, replacement of defective equipment, for final clean-up, equipment, labor, tools and in cidentals necessary to complete the work, and for removal upon completion of the project. Payment will be made under: 685-A: Underground Electric Cable, Type, AWG #, No. of Conductors - per linear foot 685-B: Aerially Supported Electric Cable, Type, AWG #, No. of Conductors - per linear foot 685-C: Temporary Lighting Assembly, Type - per each 685-D: Service Pole - per each SECTION 686 - RELOCATION OF EXISTING LIGHTING ASSEMBLIES
686.01 Description. In additional to the requirements set forth in Section 681, relocation
of existing lighting assemblies of the types indicated on the plans shall consist of removing and relocating pole, luminaire, providing new foundation and miscellaneous hardware. Wiring shall be reworked or replaced as directed below and on the plans.
686.02 Materials. Generally, all the materials needed to relocate the lighting
assembly(ies) will be existing materials. Th e lighting assemblies, wire and foundations may be either permanent or temporary. Wiring, ground rods, bolts and other items shall be relocated as per the plans. Additional items necessary for a complete working lighting assembly shall be required whether or not mentioned in these specifications.
686.02.1 Poles. Steel poles are hot-rolled weldable grade steel, galvanized in accordance
with ASTM A 123, length as indicated on the plans. Since the anchor bolt layout may vary from pole to pole, the Contractor shall field verify bolt circles of existing lighting assemblies. Timber poles, used on temporary lighting sy stems, shall conform to the applicable requirements of Section 685. Voids left by the removal of these poles shall be filled and compacted as directed by the Engineer.
686.02.2 Luminaire. Low mast luminaires are bracket arm mounted type, 250 or 400-
watt, high pressure sodium. The Contractor shall verify luminaire lamp wattage that may