SECTION 630 - BARRICADES

630-1 DESCRIPTION. This work shall consist of furnishing and erecting in accordance with the

appropriate standard sheet, permanent type barricades for highway or highway-railroad installations at the locations indicated on the plans or as directed by the Engineer.

630-2 MATERIALS. Materials shall meet the requirements of the following subsections of Section 700

- Materials and Manufacturing. Wood Posts 710-13 Galvanized Steel Barrier Posts 710-14 Corrugated Beam Guide Railing and Median Barrier 710-20 Reflective Sheeting 730-05

630-2.01 Barricades (All Permanent Types). Rails shall conform to §710-20 Corrugated Beam Guide

Railing and Median Barrier, and to the details indicated on the appropriate standard sheet. Posts shall be steel W6x15 or wood 6 x 8 inch (nominal) as indicated in the proposal and in accordance with the details shown on the appropriate standard sheet for Highway Barrier and Highway Railroad Barricade. All metal posts shall conform to §710-14 Galvanized Steel Barrier Posts.

630-3 Construction Details

630-3.01 Barricades (All Permanent Types). Posts shall be set as shown on the plans, the applicable

standard sheet, or as directed by the Engineer, and shall be set true to the line and grade and on a firmly tamped base. Rails shall be erected in such a manner as to produce a smooth appearance, and approximately parallel with the grade of the ground surface. Bolts shall be drawn tight and shall extend 1/4 to 1/2 inch beyond the nuts unless otherwise permitted by the Engineer.

630-4 Method of Measurement

630-4.01 Barricades (All Permanent Types). The quantity to be measured for payment under this work

will be the number of feet of barricade outside to outside of end posts plus an allowance of 4 feet for each complete terminal assembly including all rails as specified on the plans.

630-5 Basis of Payment

630-5.01 Barricades (All Permanent Types). The unit price bid per foot shall include the cost of all

labor, equipment and material necessary to complete the work including inspection and testing

633-3 01

NEW YORK STATE DEPARTMENT OF TRANSPORTATION Section 600 STANDARD SPECIFICATIONS (USC) January 1, 2026 VOLUME 3 information required as well as painting, excavating and backfilling. Any required signs will be paid for separately under the appropriate payment item. Payment will be made under: Item No. Item Pay Unit 630.01 Barricade (Steel Posts) Foot 630.02 Barricade (Wood Posts) Foot SECTION 631 (VACANT) SECTION 632 (VACANT)

Barricades in other states

Get an email when 630 changes

New York revises spec sections through supplementals and new editions. We check this one every week and email you the day it changes. Free, no account.

Source: Standard Specifications (US Customary Units), 2026 (Jan) Edition. Pages 881–882 of 1,489. View official source ↗

Ask about this section

Scoped to New York Standard Specifications (Construction and Materials), Section 630 — Barricades. Every answer cites the section it came from, with a verification date — don’t trust a percentage, click the citation.