SOLID -STATE FLASHING CONTROLLER 827.02
825.05 Method of Measuremen T — Vacant
825.06 Basis of Payment
The Department will pay for each pay item at the contract unit price per the specified pay unit as follows: Pay Item: Pay Unit: TRAFFIC SIGNAL CONTROLLER ASSEMBLY Each Include the cost of additional load switches and conflict monitor channels in the contract unit price for the Traffic Signal Controller Assembly . SOLID -STATE FLASHING CONTROLLER
827.01 Description
This work consists of providing, installing, and programming (initial) solid -state flashing controllers and solid -state time clocks.
827.02 Materials
Provide the following types of flashing controller as shown on the Plans: Type I - Provide a flashing controller in accordance with Subsection 827.02.A, “Controller.” Type II - Provide a flashing controller, including a solid -state time clock, in accordance with Subsection 827.02.A, “Controller,” and Subsection 827.02.B, "Time Clock."
827.02 Solid -State Flashing Controller
Provide operating instructions with each time switch. The Department defines a program step as the time and day(s) of the week when the output turns on or off. When instructed to turn the output on or off, ensure the system sets the instruction time to the minute and ensure the change occurs at the zero second of that minute. Provide a time switch capable of initiating at least six program steps. Ensure the time switch can execute five separate s kip plans programmed at least 1 year in advance. Use the integral keyboard to program skip plans. To program each plan, enter the beginning and ending dates for the time switch output deactivation. Ensure the time switch can skip durations from 1 day to 6 months. Ensure a skip plan can begin in 1 calendar year and end in the next consecutive year. Ensure the system allows entering one -day skips 6 days before the day to be skipped. After the one-day skip, ensure the time switch automatically resets and resumes normal operation. The Department will not require chronological entry of skip plan programs. Ensure review of the skip plan program without affecting the normal operation of the time switch. Ensure the display includes the skip plan number, the be ginning date, and the ending date. Provide a backup system to maintain timekeeping and the program for at least 48 hr at 77 °F [25 °C] that automatically goes online when the 115 V alternating current (AC) power source fails. When the line power resumes, ensure the unit automatically resumes normal operation and recharges the backup system. Provide a capacitive charging system. The Department will not allow batteries for the charging system. Ensure the unit displays a program loss indication if an AC pow er outage erases the time switch program. Provide a display with a discrete LED indicator and ensure the display can be reset from the integral keyboard. Ensure the display blanks and the output disables to conserve power when the time switch operates on the backup system. Ensure the unit displays the time, day of week, date, and the output relay condition. When using the 12 hr time format, ensure the unit displays “am/pm.” Provide a unit capable of switching to an alternate time display that includes s econds. Ensure a keystroke switches the display between the normal and alternate modes. Provide for program review on the clock memory, integral with the input. Ensure the program review does not affect the current time switch operation. Ensure the capab ility for mounting the time switch back panel to a backplate. Ensure that mounting holes provide a clearance for at least a No. 10 screw. Provide a time switch no larger than 4 in [100 mm] wide × 7⅜ in [190 mm] high × 3⅛ in [80 mm] deep. Provide a cover for the unit to protect the time switch from dust. Ensure easy removal of the cover to allow access to the field wiring terminals. A rain -tight cover is not necessary. Provide a terminal block capable of accommodating wire sizes from No. 20 AWG to No. 12 AWG to interface to the power line and the controlled device. Ensure that the time switch operates on 115 V (AC), 60 Hz power source, from 95 V to 135 V (AC) and from −30 °F to 160 °F [−34 °C to 71 °C]. Ensure that timing synchronizes with the power line. Provide a backup power source to maintain the timing when commercial power fails. When using the backup power, ensure timing remains SOLID -STATE FLASHING CONTROLLER 827.06 accurate within 3 sec per 24 hr period throughout the entire tempera ture range. Ensure changeovers between 115 V (AC) and the backup system do not alter the time. Provide a keyboard for system programming. Ensure the time set accurately to 1 s.
827.03 Equipment — Vacant
827.04 Construct Ion Methods
Place and wire the Type I or Type II controller unit as required by the Contract.
827.05 Method of Measuremen T — Vacant
827.06 Basis of Payment
The Department will pay for each pay item at the contract unit price per the specified pay unit as follows: Pay Item: Pay Unit: SOLID STATE FLASHING CONTROLLER Each Include the solid state time clock and the cabinet in the contract unit price for Solid State Flashing Controller . Include sign posts and concrete footings in contract unit price for sign posts in accordance with Section 851, “Galvanized Steel Sign Posts ,” and sign post footings in accordance with Section 804, “Conc rete Footings.”
828.02 Vehicle Loop Detector and Loop Detector Wire
SECTION 828 VEHICLE LOOP DETECTOR AND LOOP DETECTOR WIRE
828.01 Description
This work consists of providing and installing a solid state digital inductive vehicle loop detector and loops.
828.02 Materials
Provide and install the following materials in accordance with the latest edition of NEMA TS -1 or TS -2.