Bases & Subbases

02090Lime

OR · 2024 Standard SpecificationsBook pages 11331133View official source ↗

02090.30 1067 Section 02090 - Lime

Description

02090.00Scope - This Section includes the requirements for granular quicklime and hydrated lime

Materials

02090.10Granular Quicklime - Furnish granular quicklime (CaO) that has a minimum calcium

hydroxide content of 113 percent and meeting the fol lowing grading requirements:

Grading Requirements

Sieve Size Percent Passing (by Weight)

3/8" 100 No. 100 25 maximum

Determine grading and hydroxide content by testing according to AASHTO T 27 and AASHTO T 219.

02090.20Hydrated Lime - Furnish hydrated lime meeting the requirements of ASTM C1097

02090.30Acceptance - Provide a quality compliance certificate for lime according to 00165.35