Bases & Subbases

02090Lime

OR · 2024 Standard Specifications✓ Full text on BuildSpecBook pages 1133–1133 Save this section

Ask about Section 02090

Get a cited answer from the section text. Click the citation to check it.

One cited answer a day is free. Start a 14-day trial for unlimited, no card required.

02090.30 1067 Section 02090 - Lime Description

02090.00 Scope - This Section includes the requirements for granular quicklime and hydrated lime.

Materials

02090.10 Granular Quicklime - Furnish granular quicklime (CaO) that has a minimum calcium

hydroxide content of 113 percent and meeting the fol lowing grading requirements: Grading Requirements Sieve Size Percent Passing (by Weight) 3/8" 100 No. 100 25 maximum Determine grading and hydroxide content by testing according to AASHTO T 27 and AASHTO T 219.

02090.20 Hydrated Lime - Furnish hydrated lime meeting the requirements of ASTM C1097.

02090.30 Acceptance - Provide a quality compliance certificate for lime according to 00165.35.

Get an email when 02090 changes

Oregon revises spec sections through supplementals and new editions. We check this one every week and email you the day it changes. Free, no account.

Source: Oregon Standard Specifications for Construction, 2024 Edition. Pages 1133–1133 of 1,268. View official source ↗