1201. 2(e) 1201. 2(g) capability. Meet or exceed CSA standard 22 Part 2- 107 for harmonic distortion. Provide UPS that passes lightning testing standard as per ANSI/IEEE C62.41 category A test (6000 V spike and 3000 A ) and C62.45 test procedures. Reduce the input spike to no less than 3 V on the output, for 2000 to 1 spike attenuation. Provide capacity in volt amperes (VA) while loaded with typical computer -grade switch- mode power supplies having a power factor of 0.5 to 0.7 and crest factor of 2.7 to 3.5. Install UPS batteries, or UPS with integral battery at construction. Provide a UPS with secure monitoring and control via web browser interface and current version SNMP. Configure the monitoring to notify the TMC/RTMC through the existing Advanced Traffic Management System ( ATMS) and email notification when the UPS is operating on battery power, returns to line, in alarm, and in fault conditions.
securely monitor, identify abnormal conditions and reboot critical ITS devices. Provide an ethernet controlled remote power switch capable of individually controlling up to eight circuits that meets the following requirements:
• Input Power: 89 VAC to 135 VAC, 60± 3Hz .
• Rated Current: 12A.
• Overload Current Protection: 15A .
• Outlet Switching: minimum of six (6) switched circuits on individual 5- 15R receptacles.
• Internal Surge Protection.
• Operating Temperature: -30F to 170F .
• Ethernet Interface: RJ-45 10/100 Base- T.
• Software Controls: Individual outlets on/off, all on/off, network settings, Web UI
• Panel mount or rack mount options
• Compliance: UL/CSA/FCC
camera in the CCTV, CMS, or Wireless Radio ITS enclosure, or as indicated on the design drawings. Provide a midspan injector that is industrial grade, field -hardened for long- term freeway deployment meeting the following requirements:
• Basic Function: PSE (Power Sourcing Equipment) Midspan, compliant with IEEE 802.3af, 802.3at
• Extended supply voltage range of 18 VDC to 57 VDC or 100 VAC to 240 VAC .
• Output Nominal Voltage: 54 VDC (PoE).
• Output Power: Sized as required by the powered device (PD), 60W to 90W typical.
• Serial Transmission Speed: 10/100/1000 Mbps.
• Pin Assignment: 1:1.
• Transmission Length: 100 m.
• Input Interface: Ethernet, RJ45. 1201. 2(g) 1201. 2(i) • Output Interface: Ethernet, RJ45.
• Connection Method: CAT5e
• Circuit Protection: Reverse Polarity Protection
• Operating temperature range no less than - 30F to +167F.
• Installation : DIN Rail or Wal