913CEMENT CONCRETE CURING MATERIALS

TN · 2021 Standard SpecificationsBook pages 985985View official source ↗

913.01 976 SECTION 913 – CEMENT CONCRETE CURING MATERIALS

913.01 Water ................................ ................................ ............................ 976

913.02 Reserved ................................ ................................ ....................... 976

913.03 Reserved ................................ ................................ ....................... 976

913.04 Burlap ................................ ................................ ........................... 976

913.05 Liquid Membrane -Forming Compounds ................................ ...... 976

913.06 Sheeting Material for Curing Concrete ................................ ........ 976

913.01 Water

For use in curing Portland cement concrete, provide water that is free from all substances that may damage the concrete when applied on the surface as a curing agent.

913.02 Reserved

913.03 Reserved

913.04 Burlap

Provide burlap conforming to AASHTO M 182, Class 3 or Class 4. If Class 1 or Class 2 burlap is allowed, use at least two layers.

913.05 Liquid Membrane -Forming Compounds

Provide compounds listed on the Department’s QPL for Coatings for Concrete and conforming to ASTM C309, and use as follows:

1.Where applied texture finish is specified, use a Type 1 -D, Class B, membrane that is compatible with the texture finish.
2.Use either a Type 2 membrane or Type 1 -D, Class B, membrane on bridge decks when a pplied in combination with the water method of curing.
3.Use Type 2 membrane in all other applications.

913.06 Sheeting Material for Curing Concrete

Provide material conforming to the water vapor transmission rates specified in ASTM C171. 914.01 977 SECTION 914 – NON-METALLIC PIPE

914.01 Non -reinforced Concrete Pipe ................................ ...................... 977

914.02 Reinforced Concrete Pipe (RCP) ................................ ................. 977

914.03 Perforated Concrete Pipe ................................ ............................. 978

914.04 Drain Tile ................................ ................................ ..................... 978

914.05 Clay Pipe ................................ ................................ ...................... 978

914.06 Vitrified Clay Pipe ................................ ................................ ....... 978

914.07 Plastic and Polyethylene Corrugated Tubing ............................... 978

914.08 Precast, Concrete Box Sections ................................ .................... 978

914.09 Polyvinyl Chloride (PVC) Pipe ................................ .................... 979

914.10 High Density Polyethylene (HDPE) Pipe ................................ .... 979

914.11 Steel Reinforced Thermoplastic Ribbed Pipe (SRTRP) ............... 979

914.12 Polypropylene (PP) Pipe ................................ .............................. 979

914.01 Non-reinforced Concr ete Pipe

Provide pipe conforming to ASTM C14 for the specified diameters and strength classes. Manufacture all non -reinforced concrete pipe to meet the Department’s procedure for the Manufacture and Acceptance of Precast Drainage Structures, Noise Wall Panels, and Retaining Wall Panels.

914.02 Reinforced Concrete Pipe (RCP)

Provide pipe conforming to ASTM C76 for the specified diameters and strength classes. Elliptical pipe shall conform to ASTM C507. Arch pipe shall conform to ASTM C506. Precast reinforced concrete end sections shall conform to the cited Specifications to the extent to which they apply. Manufacture all reinforced concrete pipe to meet the Departmental procedures.

Source: Tennessee Standard Specifications for Road and Bridge Construction, 2021 Edition. Pages 985985 of 1,072.