193214.02—Detail Requirements
215.01 Description
These specifications cover materials that are chemical or organic elements that may be added to a hydrau - lic cement concrete mixture, when permitted elsewhere in these specifications, to achieve some desired effect.
215.02 Materials
215.03 Detail Requirements
Approved admixture(s) shall be used in concrete in the proportions recommended by the manufacturer to obtain the optimum effect where seasonal, atmospheric, or job conditions dictate its use. The Contractor shall use only admixtures (a) through (e) that appear on the Materials Division Approved Products List. The Department will base its initial approval of such admixtures on indepen - dent laboratory data submitted by the manufacturer verifying conformance to the specific admixture requirements. Thereafter, the manufacturer shall annually provide the Engineer a written certification that the material currently being furnished is identical in both composition and chemical concentrations to that tested by the independent laboratory. The manufacturer shall also supply a certification stating that that the chemical composition of the mate - rial is essentially the same as that of the approved mixture if the Contractor proposes to use an admixture that differs in concentration from the acceptance sample. The Department will permit the use of pump-aid admixtures when the Engineer authorizes placing con - crete by pumping, provided these are used in accordance with the manufacturer’ s recommendations. SECTION 216—W ATER FOR USE WITH CEMENT OR LIME
216.01 Description
These specifications cover water for use in mixing with cement or lime.
216.02 Detail Requirements
Water shall be clean, clear, and free from oil, acid, salt, alkali, organic matter, or other deleterious substances. Water that has been approved for drinking purposes (potable) may be accepted without testing for use in hydraulic cement concrete, cement, or lime stabilization. The Engineer must approve water from other sources as well as pumping methods planned by the Contractor before use. The acidity or alkalinity of water will be determined colorimetrically or electrometrically. Water shall have a pH between 4.5 and 8.5. When subjected to the mortar test in accordance with AASHTO T26, water shall 215.02