Effective with the December 2018 Letting 439 2019 Standard Spec ifications Section 642 Field Facilities
642.1Description
laboratories as required in the contract at engineer-approved l ocations.
642.2Materials
642.2.1 General
engineer-approved types that are floored, roofed, and weatherpr oofed, and have a minimum ceiling height of 6 feet-9 inches.
necessary fuel to maintain a mini mum temperature of 68 F during the hours occupied.
requirements, in clean and good working condition, and stock wi th sanitary supplies for the duration of the contract.
are readily accessible to proje ct personnel. Check the contents of each kit at least once each week and replenish expended items. Ensure each kit contains, at a mi nimum, a supply of latex or nitrile gloves, CPR masks, adhesive tape , pressure and cling bandages, antiseptic wipes, bite/sting swabs, cold packs, and safety goggles.
materials, provide emergency use facilities capable of flushing the eyes, or drenching the body of an exposed worker with water for 15 minutes.
screens. Securely fasten heavy screening over all windows. Use screening made of No. 2 mesh, 14- gauge or heavier, steel wire clot h, zinc coated after weaving.
padlocks. 642.2.2 Field Office 642.2.2.1 General Revise 642.2.2.1 to require a dditional technology to support in creased remote access & printing needs in the field. This change was implemented in ASP 6 effective with the December 2017 letting.
each room has a separate exteri or door and its own air conditio ner. Locate the office where a quality internet connection can be achieved.
- Two programmable touch-tone phones, one of which is cordless. Ensure that phone operations will not interfere with other telecommunications equipment. - Voice mail service or an answering machine.
connection with a modem/router and capable of supporting cloud enabled file sharing, voice over internet protocol (VoIP), video conferencing, and web based app lications. Ensure that system meets the following: - Includes a wireless netwo rk for the field office. - Can accommodate IPSec based VPN products. - Has a bandwidth range as follows: Field office with 1-5 staff: A minimum connection speed of 5 Mbps download and 1 Mbps upload. If a cable or DSL option is not available the contractor may provide a personal hotspot using cell phone tethering or other device able to achieve the specified mini mum speeds inside the field o ffice. Field office with 6 or more staff: A minimum connection speed of 10 Mbps + 1/2 Mbps per user download and 5 Mbps upload.
Effective with the December 2018 Letting 440 2019 Standard Spec ifications Projects over 50 million dollars: A minimum connection speed of 20 Mbps + 1/2 Mbps per user download and 10 Mbps upload. C oordinate network setup at the leased office with the WisDOT network team.
and scan capabilities that can accommodate both 8 1/2" x 11" and 11" x 17" paper. Re plenish paper, toner cartridges, and other supplies before fully expended. Ensure that department staff can connect to the device either directly or through the field office wirel ess network.
ergonomically correct office chai rs in working condition with, at a minimum, the following:
642.2.2.2 Type B
and 20 feet long, excluding hitch; and equipped as specified in 642.2.2.1 642.2.2.3 Type C
and 30 feet long or 8 feet wide and 40 feet long, excluding hit ch; equipped as specified in 642.2.2.1; and with the following:
642.2.2.4 Type D
and 30 feet long, excluding hitch; and equipped as specified in 642.2.2.1 ; and with the following:
642.2.3 Field Laboratory
and 16 feet long, excluding hitch; and equipped as specified in 642.2.2.1 except as follows:
1000 cubic feet per minute, in good working condition. Install the fan in an outside w all above the work bench used for asphalt extraction testing. Enclose the fan inle t and work bench top in a suitable hood or enclosure that allows effectiv e removal of the fumes from th e extraction testing.
642.3Construction
and field laboratories, or combine them with, or attached them to, any buildings use d by the contractor, unless the engineer allows in writing.
velocity winds. Locate the fiel d office in a dust-reduced and v ibration-free environment.
department, until the required fiel d office and laboratory are furnished, leveled, secured, fully equipped, and made ready for use.
their closure or removal.
contractor’s property.
Effective with the December 2018 Letting 441 2019 Standard Spec ifications (6) The contractor may furnish, i f the contract allows, the field office and field laboratory facilities jointly in cooperation with other contractors on designated projects.
642.4Measurement
laboratory acceptably completed. 642.5 Payment
items: ITEM NUMBER DESCRIPTION UNIT
642.5000 - 5999 Field Office (type) (project) EACH
642.6000 Field Laboratory (project) EACH
equipping, securing, and maintaining the facility; for telecomm unications equipment, installation, and service fees; and for providing bottled water, utilities, fuel, ventilation, and toilet fac ilities as required, either independently or jointly , for the time specified in 642.3 . Revise 642.5(3) to restrict department payment of usage f ees to long distance phone calls.
Effective with the December 2018 Letting 442 2019 Standard Spec ifications Section 643 Traffic Control
643.1Description
devices as follows: Drums Warning lights 42-inch cones Barricades Arrow boards Portable changeable message signs Flexible tubular markers Signs
643.2Materials
643.2.1 General
ATSSA publication Quality Guidelines for Temporary Traffic Cont rol Devices and Features.
24-hour emergency service on each drum, a rail of each barricad e, arrow board, the back of each sign, Portable Changeable Message Sign, and cone. Use non-refle ctive letters at least 3/4 inch but no more than 2 inches high.
contract specifies otherwise. 643.2.2 Department's Approved Products List (APL)
- Drums - Arrow boards - Barricades - Sign sheeting - Flexible tubular marker posts including bases - 42-inch cone assemblies - Warning lights and attachment hardware - Portable changeable message signs 643.2.3 Signs 643.2.3.1 General
Sign Plate Book. If neither the pl ans nor the Sign Plate Book shows the layout, conform to the FHWA Manual of Standard Highway Signs.
specifies for higher-speed locations. The engineer may allow sm aller signs if space is limited and the WMUTCD allows.
In addition, the contractor may use the following:
1.1An exterior grade B-B or better overlay plywood sign base 1/2-inch or thicker
1.2For signs 24 inches or less wide, corrugated polypropylen e or polyethylene plastic sign base
1.2.1Provide a 0.4-inch thi ck base with a 0.035-inch wall th ickness and 0.4-inch cell size
1.3An aluminum/plastic laminate sign base. 1.3.1. Provide an aluminum face d composite bas e 0.080 - 0.100 inches thick, with aluminum outer
layers 0.010 - 0.020 inches thick surrounding a polyethylene or other thermoplastic core.
specified above, the contractor may also use one or more of the following: - For signs wider than 24 inches , corrugated polypropylene or polyethylene plastic sign base. - A retroreflective roll-up sign. - A sheet aluminum sign base 0.080 inches or thicker.
contractor may use a reconditioned base if previous sheeting ma terials are removed before applying new prismatic sheeting. Do not rem ove messages and reapply new messages to existing signs with prismatic sheeting, except as specified for overlays in 643.2.3.2 .