Roof Snow Load Basics — Ground Snow, Design Limits & Engineering
The IRC does not calculate snow load for you — it hands you your jurisdiction’s ground snow load and tells you which framing tables to use. The key threshold is 70 psf: at or below it you can frame prescriptively from the tables; above it, the roof must be engineered.
Worth knowing
- Ground snow load and roof snow load are different numbers. The IRC tables build the conversion in, but an engineer designing above 70 psf will apply ASCE 7 factors for roof slope, exposure, and thermal conditions.
- Mountain jurisdictions often publish snow load by elevation rather than one number — a lot at 7,800 feet can carry a dramatically higher load than one at 6,500 in the same county. Get the number in writing from the building department.
- Drifting against a taller wall, a second story, or a parapet can multiply the load on part of a roof. Prescriptive tables assume uniform load, so unusual geometry is a reason to involve an engineer even below 70 psf.
- Adding solar panels or a heavy roof covering later does not change the snow that falls, but it does eat into the same load capacity — check the framing before re-roofing tile over a roof framed for asphalt.
Sections cite the 2021 International Residential Code and 2023 National Electrical Code as model standards. This is BuildSpec’s own summary — not ICC or NFPA text; read the authoritative language at codes.iccsafe.org. Your state may be on a different edition with amendments — check your jurisdiction page or get an Address Report.