R311 — Passenger Loading Zones
R311.1 General. Accessible passenger loading zones shall comply with R311. R311.2 Vehicle Pull-Up Space. Accessible passenger loading zones shall provide a vehicular pull-up space that is 96 inches (2440 mm) wide minimum and 20 feet (6.1 m) long minimum. R311.3 Access Aisle. Vehicle pull-up spaces shall have adjacent access aisles complying with R311.3 that are 60 inches (1525 mm) wide minimum extending the full length of the vehicle pull-up space. Access aisles shall be at the same level as the vehicle pull-up space they serve and shall not encroach on the traveled way. R311.3.1 Clearance Adjacent to Passenger Loading Zone. The center 50 percent of the length of the sidewalk, or other surface, adjacent to an accessible passenger loading zone shall be free of obstructions and comply with R302.6. R311.3.2 Marking. Access aisle surfaces shall be marked to discourage parking in them. R311.4 Surfaces. Surfaces of vehicle pull-up spaces and the access aisles serving them shall comply with R302.6, except that changes in level are not permitted. R311.5 Pedestrian Access Route Connection. Access aisles shall connect to pedestrian access routes. Where curb ramps and blended transitions are used, they shall be provided in accordance with R203.6.1.4 and comply with R304, and shall not reduce the required width or length of access aisles. Detectable warning surfaces are not required on curb ramps and blended transitions used exclusively to connect access aisles to pedestrian access routes. Exception: In alterations, the access aisle may connect to an existing pedestrian circulation path in accordance with R202.2.