Signals, Lighting & ITS (700+)

987SOIL LAYER MATERIALS

FL · 2024 Standard SpecificationsBook pages 11751175View official source ↗

987-1 Description.

All material shall be suitable for plant growth. The organic matter content of the soil layer after mixing shall be a minimum of 2.5%, a maximum of 10%, in accordance with FM 1-T267 and have a pH value of 5.5 or greater and less than or equal to 7.0 as determined in accordance with FM 5-550. The organic matter content shall be created using any of the following materials.

987-2 Materials.

Soil layer materials may be obtained from either, or a combi nation of, the following sources:

1.Excavation within the limits of construction on the project. Such material may be stockpiled or windrowed on the project in areas approved by the Engineer.
2.Designated borrow pits for the project.
3.From other sources of organic soil materials provided by the Contractor.

987-2.1 Organic Soil: This may consist of muck, mucky peat and peat and shall have an

organic matter content of 30% or more if the mineral fraction is more than 50% clay, or more than 20% organ ic matter if the mineral fraction has no clay.

987-2.2 Blanket Material: Meet the material classification shown in the Plans and

Standard Plans, Index 120-001.

987-2.3 Compost: Meet the requirements of Florida Department of Environmental

Protection Rule 62.709.550 Type Y (yard waste), Type YM (yard waste and manure), Type A (municipal solid waste compost) or Rule 62.640.850 Type AA (composted biosolids) and have unrestricted distribution.

987-2.3 1 Compost for use as a Soil Amendment: If the electrical conductivity

(EC) value of the compost exceeds 4.0dS (mmhos/cm) based on the saturated paste extract method, the compost shall be leached with water prior to application.

987-2.3 2 Compost for use as a Mulch: The compost shall contain no foreign

matter, such as glass, plastic or metal shards. The compost shall be slightly coarse to coarse in nature (over half of the solids shall be from particles 1/2 inches in size and no greater than 6 inches). Preference shall be given to compost or mulch made from unco ntaminated woody waste materials.

987-2.4 Landscape Soil: Landscape soil must be sandy loam or loamy sand with

properties of AASHTO classification A -2-4 or A-4. The soil must have an organic matter content of 5 to 10% using the loss on ignition (LOI) test in accordance with FM 1-T267 from a soil testing laboratory approved in accordance with 105 -7. Soil must be free of litter and deleterious substance such as cans, debris, particles greater than 0.50 inches, and rinsate containing lime or toxic materials. Soil must be free of noxious plants or propagules of plants listed in Florida Rule 5B - 57.007, and invasive exotic plants listed under Category I Florida Exotic Plant Pest Council. Where shown in the Plans or when approved by the Engineer, existing soil may be amended with compost or biosolids to meet the requirements of this Section. Use compost in accordance with FDEP Rule 62.709.550 and 62.709.600. Use biosolids in accordance with Florida Rule 62.640.850. FY 2023-24 Return to Table of Contents TRAFFIC CONTROL MATERIALS SECTION 990 TEMPORARY TRAFFIC CONTROL DEVICE MATERIALS

990-1 General.

This Section specifies the material requirements for temporary traffic control devices.

990-2 Retroreflective Sheeting for Temporary Traffic Control Devices.

990-2.1 Bands for Temporary Tubular Markers, Vertical Panels, Barricades,

and other Devices: Bands for temporary tubular markers, vertical panels, b arricades, and other devices shall meet the requirements of ASTM D4956 for Type III or higher retroreflective sheeting materials identified in Section 994.

990-2.2 Collars for Traffic Cones: Collars for traffic cones shall meet the

requirements of ASTM D4956 Type III or higher retroreflective prismatic sheeting materials identified i n Section 994 including supplementary requirements for reboundable sheeting. The outdoor weathering shall be for 6 months for all sheeting types .

990-2.3 Drums: Drums shall meet the requirements of ASTM D4956 for Type III

or higher retroreflective sheeting materials identified in Section 994 including supplementary requirements for reboundable sheeting.

990-2.4 Sign Panels: Meet the requirements of 990 -8.

990-3 Portable Devices (Arrow Boards, Changeable Message Signs, Regulatory Si gns,

Radar Speed Display Units and Truck Mounted Changeable Message Signs) , Automated Flagger Assistance Devices ).

990-3.1 General: All portable devices shall meet the physical display and operational

requirements of the Manual on Uniform Traffic Control Devices (MUTCD) and be listed on the Department’s Approved Product List (APL). Manufacturers seeking evaluation of their product must submit the following:

1.Certification showing that the product meets the requirements of this Section.
2.Drawings of the device along with technical information necessary for proper application, field assembly, and installation. Portable devices shall meet the following requirements:
3.Ensure that all assembly hardware less than 5/8 inch in diameter, including nuts, bolts, external screws and locking washers are Type 304 or 316 passivated stainless steel. Stainless steel bolts, screws and studs shall meet ASTM F593. Nuts shall meet ASTM F594. All assembly hardware greater than or equal to 5/8 inch in diameter shall be galvanized. Bolts, studs, and threaded rod shall meet ASTM A307. Structural bolts shall meet ASTM F3125, Grade A325.
4.The controllers and associated on -board circuitry shall meet the requirements of the Federal Communications Commission (FCC) Title 47, Subpart B, Section 15 regulations concerning the emission of electronic noise by Class A digital devices. All electronic assemblies shall meet the requirements of NEMA TS -4-2016 Section 2.
5.The controller and associated on -board circuitry shall not be affected by mobile radio, or any other radio transmissions. FY 2023-24 Return to Table of Contents