857TRAFFIC ACTUATED CONTROLLER

IL · 2022 Standard Specifications✓ Full text on BuildSpecBook pages 739–740 Save this section

Ask about Section 857

Get a cited answer from the section text. Click the citation to check it.

One cited answer a day is free. Start a 14-day trial for unlimited, no card required.

Art. 857.03 Flasher Controller CONSTRUCTION REQUIREMENTS

857.03 Installation. The traffic actuated controller shall be installed in a

completely wired cabinet, with necessary connections for proper operation. The model and serial number of the controller shall be permanently affixed on the front or top of the controller housing and readily visible. All conduit entrances into the controller cabinet shall be sealed with a pliable waterproof material. Electrical cables inside the controller cabinet shall be neatly trained along the base and back of the cabinet. Each conductor shall be connected individually to the proper terminal, and the spare conductors shall be insulated and bound into a neat bundle. Each cable shall be marked with identification meeting the approval of the Engineer and recorded on a copy of the plans for the intersection and submitted to the Engineer. The traffic actuated controller shall provide the NEMA eight phase dual ring operation for the phase designation diagram shown on the plans and all preemption sequences, coordination, or other timing features shown on the plans. A copy of all controller settings including coordination and preemption shall be provided to the Engineer.

857.04 Basis of Payment. This work will be paid for at the contract unit price

per each for FULL-ACTUATED CONTROLLER AND CABINET or RAILROAD, FULL- ACTUATED CONTROLLER AND CABINET, of the type specified. The transceiver shall be furnished with the controller only when specified as a separate pay item on the plans. SECTION 858. FLASHER CONTROLLER

858.01 Description. This work shall consist of furnishing and installing a

flasher controller and cabinet.

858.02 Materials. Materials shall be according to the following.

Item Article/Section

a.Flasher Controller .............................................................................. 1073.02 CONSTRUCTION REQUIREMENTS

858.03 Installation. The flasher controller shall be installed according to the

details shown on the plans.

858.04 Basis of Payment. This work will be paid for at the contract unit price

per each for FLASHER CONTROLLER. Master Controller Art. 860.04 SECTION 859. TRANSCEIVER

859.01 Description. This work shall consist of furnishing and installing a

transceiver with necessary connections for proper operation.

859.02 Materials. Materials shall be according to the following.

Item Article/Section

a.Transceiver ........................................................................................ 1073.03 CONSTRUCTION REQUIREMENTS

859.03 Installation. The transceiver shall be connected to the communication

interface panel. The transceiver shall be assigned a unique address in the master controller.

859.04 Basis of Payment. This work will be paid for at the contract unit price

per each for TRANSCEIVER. The interface panel, all necessary harnesses, and the programming of the controller and the master controller shall be included in this item. SECTION 860. MASTER CONTROLLER

860.01 Description. This work shall consist of furnishing and installing a

master controller with the necessary connections for proper operation.

860.02 Materials. Materials shall be according to the following.

Item Article/Section

a.Master Controller ............................................................................... 1073.04 CONSTRUCTION REQUIREMENTS

860.03 Installation. Installation of the master controller shall be as follows.

a.Communication. The contractor shall install communication hardware and software as shown in the plans. Initial communication setup charges will be paid for according to Article 109.05.
b.Housing and Cabinet. The model and serial numbers shall be affixed on the front of the housing and shall be readily visible. One circuit breaker rated at 10 A shall be provided.
c.Software. Software shall be provided and distributed as shown on the plans.

860.04 Basis of Payment. This work will be paid for at the contract unit price

per each for MASTER CONTROLLER.