B
HomeLibrariesCopilotSearchProjectsBookmarks
FeedbackHelp Desk
Libraries
Building Codes
Code LibraryIBC — BuildingIRC — ResidentialIFC — FireIPC — PlumbingIMC — MechanicalIFGC — Fuel GasIECC — EnergyNEC — ElectricalModel Codes
Specifications
CSI SpecificationsDOT SpecsTransit SpecsUSACE
Standards
TransportationRailroadFire SafetyAccessibilityStructural
Tools & References
DiagramsAssembliesProductsCalculatorsChecklistsPermits
PricingLog in
General Provisions (00100-00999)

603Steel Jetty Bank Protection

OK · 2019 Standard SpecificationsBook pages 554555View official source ↗

603.02 Steel Jetty Bank Protection

540 602.05 METHOD OF MEASUREMEN T — VACANT

602.06 Basis of Payment

The Department will pay for each pay item at the contract unit price per the specified pay unit as follows: Pay Item: Pay Unit:

A.GABIONS Cubic Yard [Cubic Meter]
B.REVETMENT MATTRESSES Square Yard [Square Meter]
C.FILTER FABRIC Square Yard [Square Meter] The Department will consider the cost of stone fill and filter sand for gabions and revetment mattresses to be included in the contract unit price for Gabions and Revetment Mattresses . Unless otherwise indicated include the cost of backfill for gabions to be included in the contract unit price for Gabions .

603.01 Description

This work consists of placing steel jetty bank protection. This consists of a mainline jetty with or without back -up jetties as shown on the Plans. The jetties consist of steel jacks connected by steel cables or reinforcing bars to a deadman anchor. The Department will establish the length of mainline and back up jetties and the distance be tween lines of jetties as shown on the Plans. The Resident Engineer may direct changes to the lengths and locations of jetties, if erosive conditions have altered the landscape and rendered the Plan design ineffective.

603.02 Materials

A.Steel Jack Provide steel jacks consisting of the following:  Three new structural steel angles, 4 in × 4 in × ¼ in × 192 in [100 mm × 100 mm × 6 mm × 4,800 mm];  Six high strength bolts with hexagon heads and nuts, ½ in × 1½ in [13 mm × 38 mm]; and  No. 6 double -anneale d smooth -wire lacing.
B.Steel Cable Provide used -steel oil -field cable that has been, inspected, respooled, and oil -treated. Ensure the steel cable has a diameter of at least ⅞ in [22.2 mm], or provide reinforcing steel bars of at least ¾ in [19 mm] in d iameter and cable clamps for fastening. STEEL JETTY BANK PRO TECTION 603.05 541 C. Deadman Provide deadman of concrete or timber. Ensure the concrete deadmen are Class A Concrete at least 3 ft × 2 ft × 1½ ft [0.9 m × 0.6 m × 0.5 m]. Ensure the timber deadmen are new creosoted railroad ties at least 6 in × 8 in × 96 in [152 mm × 203 mm × 2,400 mm], or creosoted timber pile cutoffs with a diameter of at least 7 in [178 mm] at the smallest end and a length of 8 ft [2.40 m].

603.03 Equipment — Vacant

603.04 Construction Methods

A.Constructing Jack s Bolt three steel angles together so each angle is perpendicular to the other two angles. Construct the jacks to a height of at least 9 ft [2.7 m], and lace with at least four wire lines as follows:  Tie the outside lacing line at each angle.  Pass the sec ond lacing line through the angles 2 ft [0.6 m] from the ends.  Pass the third lacing line through the angles 4 ft [1.2 m] from the ends.  Pass the inside lacing line through the angles 6 ft [1.8 m] from the ends.
B.Anchoring Jacks Use double runs of steel cable or reinforcing bars to anchor the jacks. Pass one cable or bar on each side of the jack and apply a cable clamp to hold the cables together and to keep the jack in place. For a mainline jetty, anchor the cables or bars at each end with a deadman. For backup jetties, fasten the cables or bars to the mainline at a steel jack and anchor to a deadman at the opposite end. Minimize the use of splices and, if necessary, place splices only at a jack. Make splices, construct end connections to timber deadme n, or connect backup jetties to a mainline jetty by wrapping each steel cable around the jack or deadman at least twice and fasten with double cable clamps. Connect concrete deadmen as shown on the Plans. Splice reinforcing bars with a double -flare v -groove weld of at least 3 in [75 mm] in accordance with the current edition of the AWS “Reinforcing Steel Welding Code .”
C.Placing the Deadman Place the deadman in a trench and ensure the pull is at right angles to the deadman. Ensure the deadman bears on u ndisturbed earth. Bury the deadmen at least 6 ft [1.8 m] deep, measured to the bottom of the deadman. Backfill the trench and compact the soil to the density of adjacent in -situ soil.

603.05 Method of Measuremen T

The Resident Engineer will measure the st eel jacks by the number of jacks constructed, placed, and anchored. For the mainline jetty, the Resident Engineer will measure the length of steel cable from the center of the steel jack to the center of the deadman. For backup jetties, the Resident Engin eer will measure the length of steel cable from the tie to the mainline jetty to the center of the deadman.

609.02 Integral Curb, Combined Curb and Gutter, Bituminous Curb and Concrete Curb

542 603.06 BASIS OF PAYMENT The Department will pay for each pay item at the contract unit price per the specified pay unit as follows: Pay Item: Pay Unit:

A.STEEL JACK Each
B.STEEL CABLE Linear Foot [Meter]
C.DEADMAN Each Include the cost of excavation and backfill for placing the deadman to be included in the contract unit price for Deadman . Unless otherwise specified, the Department will consider the cost of excavation for placing steel jacks to be included in the contract unit price for Steel Jack and Steel Cable . SECTION 609 INTEGRAL CURB, COMBINED CURB AND GUTTER, BITUMINOUS CURB AND CONCR ETE CURB

609.01 Description

This work consists of constructing integral curb, combined curb and gutter, bituminous curb, and concrete curb.

609.02 Mater Ials

Provide Class A concrete for integral curb, combined curb and gutter, or concrete curb in accordance with Section 701, “Portland Cement Concrete.” Provide Type S5 or Type S6 asphalt concrete for bituminous curb in accordance with Subsection 708.04, “Composition of Mixtures,” except provide asphalt concrete with an asphalt content of 1.15 times the asphalt content required by the appropriate job -mix formula. Provide sealant material in acco rdance with the following subsections, or as otherwise approved by the Resident Engineer: Material: Subsection: For Concrete Curb 701.08 For New Concrete Pavement 701.08.F For Most Joint Rehabilitation 701.08.F For Integral Concrete Curb Joints 701.08.D For Combined Curb and Gutter Joints 701.08.D

Source: Oklahoma Standard Specifications for Highway Construction, 2019 Edition. Pages 554555 of 935.