714.5(a) 714.6(c) Adequate number Chair and stools 1 Individual Access Phone line 1 Internet Service: a wired broadband Internet service, for exclu sive use by Department personnel for official business purposes only . Choose a service that provides the fastest available highspeed broadband internet access, with a minimum connection of 5 Mbps per inspector, to the account by means of a Cable or Digital Subscriber Line (DSL). Provide a wireless broadband router, with a minimum -security setting of WPA2, to connect to the provided wired broadband. Based on the specific type of high -speed connection provided, furnish a compatible modem with built -in hardware firewall protection. If such high -speed wired broadba nd connection is not attainable at the Inspector Office desk area alternate internet connectivity options must be submitted to the CSME for review and acceptance. Demonstrate connectivity with the Internet Service Provider once the service is initiated. To ensure reliability and continued access , audits of this connection may be done at any time by a qualified PennDOT/OA IT Personnel . 1 Telephone (business and emergency calls only) and answering machine or voice -mail 1 Sanitary electric water cooler 1 Fire extinguisher Adequate number Cupboards, closets, lockers 1 First-aid kit (OSHA 1926.50(d) and 1926.50 Appendix A compliant)
714.6FABRICATION —
approval to produce a new product type. Plants must produce test sections and conduct a prefabrication meeting as specified in Section 1085.3(g) for products containing an architectural finish or requiring staining or both . Use only qualified welders for all welding operations , including tack welds. Submit a weld procedure specification (WPS) for review and approval to the CSME for welding of reinforcement or steel embedded in concrete .
as indicated, within specified tolerances. Secure reinforcing in beds and forms using chairs or blocking so the reinforcing maintains its position during placement and vibration of concrete. Bars may be fabri cated into cages by tying and tack welding. Do not tack weld epoxy coated ; galvanized ; uncoated, corrosion - resistant; stainless steel; or Grade 60 reinforcement bars. Use acceptable chairs or ties for su pport. If bar spacing is greater than or equal to 12 inches, tie all intersections with annealed iron wire or metal clips. If bar spacing is less than 12 inches, either tie all intersections or tie alternate intersections with annealed iron wire or metal clips in each direction to provide a staggered tie layout prohibiting movement of reinforcement bars during manufacturing. For e