B
HomeLibrariesCopilotSearchProjectsBookmarks
FeedbackHelp Desk
Libraries
Building Codes
Code LibraryIBC — BuildingIRC — ResidentialIFC — FireIPC — PlumbingIMC — MechanicalIFGC — Fuel GasIECC — EnergyNEC — ElectricalModel Codes
Specifications
CSI SpecificationsDOT SpecsTransit SpecsUSACE
Standards
TransportationRailroadFire SafetyAccessibilityStructural
Tools & References
DiagramsAssembliesProductsCalculatorsChecklistsPermits
PricingLog in
General Provisions (00100-00999)

632HIGHWAY SIGNS AND DELINEATORS

SD · 2025 Standard SpecificationsBook pages 427431View official source ↗

632 Page 427632 HIGHWAY SIGNS AND DELINEATORS

632.1DESCRIPTION

This work consists of furnishing materials, making and preparing signs and delineators, erection and installation of signs and delineators, and performing incidental work.

632.2MATERIALS

Materials will conform to the following sections: A.Highway Signs and Delineators: Section 982. B.Reinforcing Steel: Section 1010 . C.Concrete: Section 462. D.Bolts: High-strength bolts will conform to Section 972. Bolts for mounting sign panels to posts and backing hardware will conform to Section 982.

632.3CONSTRUCTION REQUIREMENTS

Highway signs, delineators, and object markers will comply with the current edition of the MUTCD and Standard Highway Signs, issued by the U.S. Department of Transportation, FHWA. A.Signs: 1.Location and Position: The location of each sign will be established by a stake bearing the sign number as determined from the plans. Posts will be in a plumb position and the flanges of structural shape posts or other supports will lie in the same plane. The post will not extend above the top of the sign. Extruded panels will be flat and straight and will be erected on the posts in a leveled position with the face of each extrusion flush with adjoining extrusions. Bolted connections between adjoining panels will be straight. Offsets or gaps exceeding 1/16 inch will not be permitted. 2.Post Size: Post size will be as specified in the contract for each sign. Sign post lengths shown in the contract are estimates for bidding purposes only. The Contractor will field verify the post length prior to ordering. 3.Date Decal: The Contractor will affix a date decal to each new sign installed. The date decal is a 2 inch by 2 inch self-adhesive sticker with removable paper backing. The date decal displays the last two digits of the year the sign was installed and will consist of two contrasting colors. The date decal will be placed in the lower left corner on the back of flat aluminum signs. The date decal will be placed in the lower left corner on the front of extruded aluminum signs. The date decal on extruded aluminum signs will be of the same color as the background of the sign and will be retroreflective. Sign supports and other 632 Page 428obstructions will not block the view of the date decal upon completion of the sign installation. B.Object Markers: Object markers of the type specified will be erected at the locations shown in the plans or as directed by the Engineer. C.Delineators: Delineators will be mounted as shown in the plans. D.Perforated Tube Posts: Perforated tube posts will be installed in accordance with the contract or as directed by the Engineer. E.Steel Posts: Steel posts longer than the required length will be cut off or spliced in a satisfactory manner. Areas where the galvanizing has been damaged will be coated with an approved zinc rich paint. Structural properties of steel posts to be reused will not be modified without the approval of the Engineer. F.Wood Posts: Wood posts will be embedded a minimum of 4 feet. Wood posts longer than the required length will be cut off or set deeper. Holes for setting wood posts will be a minimum diameter of 6 inches larger than the greatest side dimension of the post. The posts will be set, backfilled, and compacted with material placed in layers not to exceed 6 inches. G.Sign Bridges and Overhead Cantilever Sign Supports: Sign bridges and overhead cantilever sign supports will be constructed in accordance with the details in the plans and at the locations shown. Anchor bolts/rods will be tightened in accordance with Section 635.3 E. H.Bridge Mounted Sign Support Assemblies: Bridge mounted sign support assemblies will be constructed in accordance with the details and at the location shown in the plans. I.Fixed Base Assemblies: Fixed base assemblies will be assembled in accordance with details in the plans. High strength bolted connections will be tightened as specified using load indicator washers. J.Slip Base Assemblies: Slip base assemblies will be assembled in accordance with the details in the plans. The top of the concrete footing/grout pad will be placed flush with the finished grade. The mounding of soil around the footing will not be permitted. K.Reflective Sheeting: Reflective sheeting will be of the type specified. L.Concrete Footings: 1.Construction: Concrete footings will be constructed as shown in the plans. When the signpost footings extend into rock, the portions of the plan specified depths in solid rock should be reduced by one half. Reduction from the plans shown quantities of concrete for footings will be made for any changes in footings depths. Posts will be anchored to footings as shown on the plans. Dirt excavated for the footings will be disposed of as directed by the Engineer. 632 Page 4292.Protection and Cure: Concrete footings will be protected and cured in accordance with Section 460, except the minimum curing time will be 72 hours. The finished surface of the concrete footings will be flush with the existing ground and will present a neat and smooth appearance. M.Remove, Salvage, Relocate, and Reset Sign: The Contractor will remove signs, post, and bases for reset as shown in the plans. The Contractor will reuse existing extruded aluminum panels, posts, footings, and hardware where specified. All existing posts, bases, and signs listed in the plans that are scheduled for removal will be dismantled. All bolts, nuts, and washers will be placed in containers to keep the hardware separated. Backing materials will be separated from the signs and may be reused at the Contractor’s discretion. Non-threaded connections (rivets) will be cut when necessary to reduce sign sections to a 4 foot x 6 foot maximum size. Wooden posts will be carefully removed to avoid damage and cleaned of excess dirt and neatly stockpiled separate from the steel posts. The resultant holes in the ground from removal of wooded posts will be backfilled to the satisfaction of the Engineer.

632.4METHOD OF MEASUREMENT

A.Signs: Signs will be measured to the nearest 0.1 foot and the area computed to the nearest 0.1 square foot of the sign face. Deduction will not be made for rounded corners. B.Object Markers: Object marker quantities will be determined by count of each type regardless of size. C.Delineators: Delineator quantities will be determined by count of each type. D.Perforated Tube Posts: Post quantities for perforated tube posts will be measured to the nearest 0.1 foot. The measured length will be from the top of the base to the top of the post. Measurement of the post beyond the required length will not be made. E.Steel Posts (Structural and Pipe): Post quantities for steel posts will be measured to the nearest 0.1 foot for the various sizes and types. The measured length will be from the top of the base to the top of the post. Measurement of the post beyond the required length will not be made. F.Wood Posts: Post quantities for wood posts will be measured to the nearest 0.1 foot for the various sizes. The measured length of wood posts will be from the ground to the top of the post. The embedded 4 foot length will not be measured for payment. G.Sign Bridges and Overhead Cantilever Supports: Sign bridges and overhead cantilever supports will be measured on a per each basis. H.Bridge Mounted Sign Support Assemblies: Bridge mounted sign support assemblies will be measured on a per each basis. I.Fixed Base Assemblies: Field measurement will not be made. J.Slip Base Assemblies: Field measurement will not be made. 632 Page 430K.Reflective Sheeting: Field measurements will not be made. L.Concrete Footings: Concrete footings of the various diameters will be the depth of concrete to the nearest 0.1 foot. M.Remove, Salvage, Relocate, and Reset Sign: Measurement will be the actual count of signs on a per each assembly basis regardless of the number of signs or posts at each assembly.

632.5BASIS OF PAYMENT

A.Signs: Sheet aluminum and extruded aluminum signs will be paid for at the contract unit price per square foot. Payment will be full compensation for furnishing and installing materials including borders, legend, date decal, and edge trim. B.Object Markers: Object markers will be paid for at the contract unit price per each, regardless of size. Payment will be full compensation for furnishing and installing materials, including posts, reflective panels, and hardware. C.Delineators: Delineators will be paid for at the contract unit price per each, regardless of size. Payment will be full compensation for furnishing and installing materials, including posts, reflectors, and hardware. D.Perforated Tube Posts: Perforated tube posts will be paid for at the contract unit price per foot. Payment will be full compensation for furnishing and installing materials, including post anchors, anchor sleeves, mounting hardware, telescoped inner post sections, and anchor plates. E.Steel Posts (Structural and Pipe): Steel posts, of the various sizes and types will be paid for at the contract unit price per foot. Payment will be full compensation for furnishing and installing materials, including sign posts connections, splices, cutoffs, base assemblies, frame assemblies, and stiffeners. F.Wood Posts: Wood Posts, of the various sizes and types will be paid for at the contract unit price per foot. Payment will be full compensation for furnishing and installing materials, including sign post connections, frame assemblies, and stiffeners. G.Sign Bridges and Overhead Cantilever Supports: Sign bridges and overhead cantilever supports will be paid for at the contract unit price per each. Payment will be full compensation for furnishing labor, equipment, and materials. Extruded aluminum signs will be paid for separately at the contract unit price per square foot. H.Bridge Mounted Sign Support Assemblies: Bridge mounted sign support assemblies will be paid for at the contract unit price per each. Payment will be full compensation for labor, equipment, and materials. Extruded aluminum signs will be paid for separately at the contract unit price per square foot. I.Fixed Base Assemblies: Separate payment will not be made for fixed base assemblies. The fixed base assemblies will be considered incidental to the sign post furnished. 632 Page 431J.Slip Base Assemblies: Separate payment will not be made for slip base assemblies. The slip base assemblies will be considered incidental to the sign post furnished. K.Reflective Sheeting: Separate payment will not be made for reflective sheeting. The reflective sheeting will be considered incidental to the sign furnished. L.Concrete Footings: Concrete footings of the various diameters will be paid for at the contract unit price per foot. Payment will be full compensation for excavation and backfilling and for furnishing and installing materials including stub posts, bolts, castings, reinforcing steel, and other hardware. M.Remove, Salvage, Relocate, and Reset Sign: Payment will be full compensation to remove and reset existing signs and will include all costs for labor and equipment necessary to remove, dismantle, backfill holes, and deliver salvaged material to the appropriate Department shop at the contract unit price per each assembly. 633 Page 432633 PAVEMENT MARKING

633.1DESCRIPTION

This work consists of furnishing and applying pavement marking materials and surface grooving of Portland cement concrete pavement or asphalt concrete pavement.

633.2MATERIALS

Materials will conform to the following Sections: A.Cold Applied Plastic Pavement Markings and Legends: Section 983. B.Paint: Section 980. C.Glass Beads: Section 981.

633.3CONSTRUCTION REQUIREMENTS

A.Cold Applied Plastic Pavement Marking and Legends: 1.Prefabrication: Prefabricated legends and symbols will conform to the applicable shapes and sizes as outlined in the current edition of the MUTCD. 2.Width Tolerance: Width will be as specified with a tolerance of ±1/8 inch. 3.Surface and Air Temperature: The surface will be 70°F minimum, and ambient air temperature of 60°F minimum and rising, at a season when daily highs are above 70°F and lows are above 40°F. If the manufacturer’s recommendations allow for installation at temperature below the minimum required by this section, the Contractor may install the material in accordance with the manufacturer’s recommendations, including any additional adhesives. 4.Pavement Condition: Pavement must be dry and free of dirt, dust, and oily substances. 5.Application Instructions: The manufacturer will supply proper application instructions and will identify activators and adhesives which are to be used. An adhesive activator supplied by the manufacturer will be utilized on applications of this material, except on newly installed asphalt when the surface temperature is 80°F or above. A copy of the application instructions will be provided to the Engineer prior to use. The plastic markings will be manufactured and packaged in a manner, which will permit storage at normal temperatures for up to one year after purchase. 6.Lane Lines : Lane lines will not be placed over a longitudinal pavement joint and will not be installed closer than 1½ inches from the joint. Lane lines will not deviate more than 1 inch per 200 feet, nor will any deviations be abrupt. 7.Bonding: To ensure a uniform bond of material to asphalt or concrete surfaces after initial laydown, rolling of the material with a truck wheel, car wheel, or heavy hand roller in accordance with the manufacturer’s recommendations is required.

Source: South Dakota Standard Specifications for Roads and Bridges, 2025 Edition. Pages 427431 of 596.