30 CFR Part 56Public Domain
§ 56.19018 — Overtravel by-pass switches
Subpart R — Personnel Hoisting
When an overtravel by-pass switch is installed, the switch shall function so as to allow the conveyance to be moved through the overtravel position when the switch is held in the closed position by the hoistman. The overtravel by-pass switch shall return automatically to the open position when released by the hoistman.