30 CFR Part 56Public Domain
§ 56.19027 — End attachment retermination
Subpart R — Personnel Hoisting
Damaged or deteriorated wire rope shall be removed by cutoff and the rope reterminated where there is—
(a)More than one broken wire at an attachment;
(b)Improper installation of an attachment;
(c)Slippage at an attachment; or
(d)Evidence of deterioration from corrosion at an attachment.