When a misfire is suspected, persons shall not enter the blast area—

(a)For 30 minutes if safety fuse and blasting caps are used;

(b)For 15 minutes if any other type detonators are used; or

(c)For 30 minutes if electronic detonators are used, or for the manufacturer-recommended time, whichever is longer.