§ 57.6800 — Storage facilities

Subpart E — Explosives

When repair work which could produce a spark or flame is to be performed on a storage facility—

(a)The explosive material shall be moved to another facility, or moved at least 50 feet from the repair activity and monitored; and

(b)The facility shall be cleaned to prevent accidental detonation.