§ 57.6407 — Circuit testing

Subpart E — Explosives

A blasting galvanometer or other instrument designed for testing blasting circuits shall be used to test the following:

(a)In surface operations—

(1)Continuity of each electric detonator in the blasthole prior to stemming and connection to the blasting line;

(2)Resistance of individual series or the resistance of multiple balanced series to be connected in parallel prior to their connection to the blasting line;

(3)Continuity of blasting lines prior to the connection of electric or electronic detonator series; and

(4)Total blasting circuit resistance prior to connection to the power source.

(b)In underground operations—

(1)Continuity of each electric detonator series; and

(2)Continuity of blasting lines prior to the connection of electric or electronic detonators.

Public Domain: 30 CFR Part 57 (MSHA Safety and Health Standards — Underground Metal and Nonmetal Mines) is a U.S. government publication and is not subject to copyright. Text extracted from the official source ↗. Figures are served from the eCFR; if one does not load, use the link in its place.