B
HomeLibrariesCopilotSearchProjectsBookmarks
FeedbackHelp Desk
Libraries
Building Codes
Code LibraryIBC — BuildingIRC — ResidentialIFC — FireIPC — PlumbingIMC — MechanicalIFGC — Fuel GasIECC — EnergyNEC — ElectricalModel Codes
Specifications
CSI SpecificationsDOT SpecsTransit SpecsUSACE
Standards
TransportationRailroadFire SafetyAccessibilityStructural
Tools & References
DiagramsAssembliesProductsCalculatorsChecklistsPermits
PricingLog in
Signals, Lighting & ITS (700+)

955TIMBER TREATMENT (INCLUDING TREATING MATERIALS)

FL · 2024 Standard SpecificationsBook pages 10961099View official source ↗

TIMBER TREATMENT (INCLUDING TREATING MATERIALS)

955-1 General.

The work specified in this Section is the treating of structural timber, timber piling and timber posts, bracing and railing. The method of treatment and determination of assay results for all such timber materials shall be in accordance with American Wood Protection Association (AWPA) Use Category System (UCS) - U1, with the exceptions and additions as specified herein. Use approved producers listed on the Department’s Production Facility Listing for timber components located in https://mac.fdot.gov/smoreports . Producers seeking inclusion shall meet the requirements of Section 105.

955-2 Preservative.

955-2.1 Guardrail Post, Fence Post, Bracing and Railing on Pedestrian Bridge s,

Buildings, and Rest Areas in Above Ground, Ground Contact, Fresh Water Immersion Applications (Pedestrian Use) : Provide guardrail post, fence post, bracing and railing in accordance with Table 955-1. Approved producers should provide a certification sho wing the treatment and assay results with every shipment. FY 2023-24 Return to Table of Contents Table 955-1 Product Type / Species Category Treatment Assay Results Guardrail Posts, Fence Post, Bracing, & Railing Southern Yellow Pine UC4A Micronized Copper Azole (MCA) ≥ 2.4 kg/m3 or ≥ 0.15 pcf Copper Azole Type C (CA-C) Copper Azole Type B (CA-B) ≥ 3.3 kg/m3 or ≥ 0.21 pcf Alkaline Copper Quat Type A, (ACQ-A) ≥ 6.4 kg/m3 or ≥ 0.40 pcf Alkaline Copper Quat Type B, (ACQ-B) Alkaline Copper Quat Type C, (ACQ-C) Alkaline Copper Quat Type D, (ACQ-D)

955-2.2 Guardrail Posts, Fence Posts, Bracing and Sheet Piling in Above Ground,

Ground Contact or Fresh Water Immersion Applications (Non -Pedestrian Use) : Provide guardrail post, fence post, bracing and sheet piling in accordance with Table 955-2. Approved producers should provide a certification showing the treatment and assay results with every shipment. FY 2023-24 Return to Table of Contents Table 955-2 Product Type / Species Category Treatment Assay Results Guardrail Posts, Fence Post, Bracing Southern Yellow Pine UC4A MCA ≥ 2.4 kg/m3 or ≥ 0.15 pcf CA-C CA-B ≥ 3.3 kg/m3 or ≥ 0.21 pcf Ammoniacal Copper Zinc Arsenate (ACZA) ≥ 6.4 kg/m3 or ≥ 0.40 pcf Chromated Copper Arsenate Type C (CCA) ACQ-A ACQ-B ACQ-C ACQ-D Piling Cypress None N/A Southern Yellow Pine UC4B UC4C ACZA ≥ 9.6 kg/m3 or ≥ 0.60 pcf CCA ≥ 9.6 kg/m3 or ≥ 0.60 pcf Pacific Coast Douglas Fir ACZA ≥ 9.6 kg/m3 or ≥ 0.60 pcf

955-2.3 Guardrail Post, Fence Post, Bracing and Sheet Piling for Salt and Brackish

Water Applications (Non -Pedestrian) : Provide guardrail post, fence post, bracing and sheet piling in accordance with this section and Table 955-3. Approved producers should provide a certification showing the treatment an d assay results with every shipment. Table 955-3 Product Type / Species Category Treatment Assay Results Guardrail Posts, Fence Post, Bracing Southern Yellow Pine UC4C CCA ≥ 9.6 kg/m3 or ≥ 0.60 pcf Piling Cypress UC5C None N/A Southern Yellow Pine CCA Zone 1 (Outer): ≥ 40 kg/m3 or ≥ 2.50 pcf Zone 2 (Inner): ≥ 24 kg/m3 or ≥ 1.50 pcf Pacific Coast Douglas Fir ACZA 40 kg/m3 or ≥ 2.50 pcf FY 2023-24 Return to Table of Contents

955-2.4 Structural Timber : Provide structural timber in accordance with this section

and Table 955 -4. Approved producers should provide a certification showing the treatment and assay results with every shipment. Table 955 -4 Product Type / Species Category Treatment Assay Results Boards, Dimensional, Timber Southern Yellow Pine UC4B CCA ≥ 9.6 kg/m3 or ≥ 0.60 pcf

955-3 Handling Waterborne Preservative Treated Piling.

In handling of piles that have been treated with chromated copper arsenate (CCA) or ammoniacal copper zinc arsenate (ACZA), cable slings shall be used. Mechanical grabbers or pointed tools shall not be permitted. Rough or careless handing shall be avoided at all times.

955-4 Identification of Treating Plants for Round Piling.

The treating plant shall brand, or place a distinctive permanent mark, on each round pile, approximately 6 feet from the butt end, such that the plant responsible for the treatment ca n be readily determined at any time during the service life of the piling. FY 2023-24 Return to Table of Contents METAL MATERIALS AND FABRICATION DETAILS FOR METAL ITEMS SECTION 960 POST-TENSIONING COMPONENTS

960-1 Description.

This Section covers all post -tensioning (PT) systems and components remaining in a completed structure, including temporary erection PT left in -place and permanent PT for design capacity. The submittal for approval of PT systems must use materials and components meeting the requirements of this Section and Section 462. Submit PT system shop drawings to the Engineer f or review and acceptance in accordance with Section 5. The PT system shop drawings must include component drawings, system drawings, and test reports. The acceptance of a PT system for use on the project is based on the exact major components, as defined i n 960-2, that were used in system testing and that are shown on the approved PT system shop drawings .

960-1.1 Material References: Meet the requirements of this Section and the following:

Epoxy Compounds* ................................ ............Section 926 Bar (post-tensioning) ................................ ..........Section 933 Duct Filler for Post Tensioned Structures* .........Section 938 Reinforcing Steel (mild) ................................ .....Section 415 Parallel Wire (post -tensioning) ........................... Section 933 Strand (post -tensioning) ................................ ......Section 933 *Use products listed on the Department’s Approved Product List (APL).

960-2 Component Standards.

All PT system components must be materials compatible with the filler material and installation process used to encapsulate the tendons. The component materials must not chemically degrade during the service life of the structure. The service life of the structure is 75 - years unless specified otherwise in the Contract Documents . The following are major components and must be marked with the manufacturer’s name, trademark, model number, and size corresponding to catalog designation: an chorages, bearing plates, trumpets, caps, duct couplers, connections, “O” -rings, heat shrink tubing, duct, and local zone reinforcement. Any of these items that cannot be marked must be contained in packaging or appropriately tagged with the necessary info rmation. The following are examples of common off -the-shelf accessories and need not be stamped: bolts, washers, inlets, outlets, drains, ports, valves, plugs, nipples, hose adapters, and grease. Substitution, modification, or deletion of any major component of the PT system, excluding local zone reinforcement, after system testing and approval by the Engineer is not permitted. Provide only PT systems utilizing tendons completely encapsulated in grout or flexible filler filled anchorages and ducts. Do no t use systems transferring prestress force by bonding prestress steel strand directly to concrete. Embedded anchorages for bars are permitted. Strand or strand-tendon couplers are not permitted.

960-2.1 Anchorage Assembly:

1.Construct anchorages from f errous metal. FY 2023-24 Return to Table of Contents
Source: Florida Standard Specifications for Road and Bridge Construction, 2024 Edition. Pages 10961099 of 1,299.