880.1 General Description

This section includes the requirements for water used in Portland cement mixtures.

880.1.01 Related References

A. Standard Specifications General Provisions 101 through 150. B. Referenced Documents AASHTO T 26 AASHTO T 71 ASTM C 403 GDT 26

880.2 Materials

880.2.01 Water for Portland Cement Mixtures

A. Requirements 1. Use water that is reasonably clear without oil, salt, acid, alkali, organic, and other injurious substances. 2. The Department may allow drinking water that is used for ordinary household use without testing it. 3. Do not use water from shallow, muddy, or marshy surfaces. Test and approve all other sources before using them. 4. When the source of water is relatively shallow, ensure that the source depth and intake exclude silt, mud, grass, and all other foreign material. 5. Do not use water with detergents that will entrain air in Portland cement concrete. 6. Do not use water with impurities above the following limits: Impurity Concentration Acidity or alkalinity calculated in terms of calcium carbonate 0.05% Total organic solids 0.05% Total inorganic solids 0.05% Sulfate (SO4) 0.05% Chloride 0.01% B. Fabrication General Provisions 101 through 150. C. Acceptance The Department will reject any water that, when compared with accepted water, shows any indication of unsoundness, marked change in time of set, or reduction of more than 10 percent in mortar strength. Test as follows: Test Method Quality of water, solids ppm AASHTO T 26 Setting time of concrete mixtures ASTM C 403 Mortar making properties AASHTO T 71 Air content of concrete GDT 26 SO4 ppm, Alkalis, ppm ASTM D 516 Cl, ppm AASHTO T 260 D. Materials Warranty General Provisions 101 through 150.

880.2.02 Recycled Wash Water

A. Requirements Recycled Wash Water shall conform to AASHTO M 157 and meet the following requirements: Chemical Designation Limits Test Method SO4, ppm 3000 ASTM D 516 Alkalis, ppm 600 ASTM D 516 Total Solids, ppm 50,000 AASHTO T 26 Cl, ppm 600 AASHTO T 260 B. Fabrication General Provisions 101 through 150. C. Acceptance Conduct test methods according to the following: Quality of Water, Solids,ppm AASHTO: T26 Setting Time of Concrete Mixtures ASTM: C 403 Mortar Making Properties AASHTO: T 71 Air Content of Concrete GDT: 26 SO4, ppm, Alkalis, ppm ASTM D 516 Cl, ppm AASHTO T 260