569 SECTION 722 SCOPE

722.01.01 Material Covered. This specification covers the quality of water.

REQUIREMENTS

722.02.01 General. Water for embankments, backfill, subgrade, base, landscaping, and surface courses and

cement concrete curing shall be free from an excessive amount of acids, alkali, oil, and other substances which will cause damage to the above mentioned items. PHYSICAL PROPERTIES AND TESTS

722.03.01 Concrete Use. Submit two, 1 liter (1 quart), samples of water for tests, obtained and shipped in clean

containers carefully packed and labeled. Tests will be made according to AASHTO T26. Water with a pH less than 4.5 or greater than 8.5 and a resistivity less than 500 ohm •cm will be tested according to AASHTO T26. Any indication of unsoun dness, marked change in time of setting, or a reduction of more than 10% in strength from results obtained with concrete mixtures containing the water of satisfactory quality shall be sufficient cause for rejection of the water under tests.

722.03.02 Cold Recycle Use. Submit a 1 liter (1 quart) sample of the water to be used a minimum of 15

working days before the start of cold recycle operations. The water shall not contain more than 500 ppm total sulfates. SECTION 724 FENCE MATERIALS SCOPE

724.01.01 Materials Covered. This specification covers the quality of barbed wire, woven wire, and chain- link

fabric fencing, fence posts, gates, and miscellaneous fence hardware. REQUIREMENTS

724.02.01 Samples and Certificates of Inspection. Furnish 2 certificates covering each order of material by

the manufacturer, certifying that the various metal components comply with the requirements herein. Deliver the certificates at the time of, or before, delivery of the or der. PHYSICAL PROPERTIES AND TESTS

724.03.01 Wood Posts. Intermediate braced posts and braces shall be of the same type as line posts.

End, gate, and corner post assemblies, including bracing timber, shall be sawed lumber and shall conform to the grading requirements of Section 718. They shall be of Douglas Fir, Western Larch, or Southern Pine. Line posts and intermediate braced posts and bracing shall be round and shall be of Douglas Fir, Southern Pine, Lodgepole Pine, or Western Larch manufactured from sound live trees well seasoned and free from large knots, shakes, or splits or other defects which will impair their strength or durability. Peel the posts and braces to remove all outer bark and all inner cambium bark, except an occasional strip of inner bark may remain if not over 13 mm (1/2 in.) wide or 75 mm (3 in.) long. Trim knots flush with the side, remove spurs and splinters, and cut ends square. The small end of round line posts and braces shall be between 90 and 115 mm (3.5 and 4.5 in.) in cross sectional dimension; the small end of intermediate braced posts shall be between 140 and 165 mm (5.5 and 6.5 in.) in cross sectional dimension. The allowable taper from end to end of round posts and braces shall not exceed 38 mm (1.5 in.). Pressure tre at posts and braces according to Section 718. Treat all posts and braces with the same type of preservative. When pressure treated materials have been damaged or when it has been absolutely necessary to cut or bore into them, after delivery to the job sit e, carefully field treat all exposed untreated wood with preservative applied either by thorough swabbing or by an approved bolt -hole treater. Corner, end, pull, line, brace, and gate posts shall be of the type, size weight, and length shown on the plans.

724.03.02 Metal Posts. Steel pipe posts shall be Class 1 or Class 2 and conform to the following:

1.Class 1 pipe posts shall be galvanized standard weight steel pipe ( Schedule 40) conforming to ASTM F1083.
2.Class 2 pipe posts shall be Grade 1 or 2 c onforming to AASHTO M181, except that Grade 2 shall be only zinc plus organic coated. Fabricate C -section and Type II posts and braces from roll formed steel conforming to ASTM A 1011, Grade 45 and zinc coat or zinc plus organic coat according to AASHTO M181. Pre-galvanized C -sections and Type II posts may be used provided the edges are coated in conformance with ASTM A780. Manufacture T -section posts of steel conforming to ASTM A283, A663 , or A675, or manufacture to comply with AASHTO M281, T -section type. Manufacture T -section posts to tolerances and workmanship as provided in AASHTO M281.