B
HomeLibrariesCopilotSearchProjectsBookmarks
FeedbackHelp Desk
Libraries
Building Codes
Code LibraryIBC — BuildingIRC — ResidentialIFC — FireIPC — PlumbingIMC — MechanicalIFGC — Fuel GasIECC — EnergyNEC — ElectricalModel Codes
Specifications
CSI SpecificationsDOT SpecsTransit SpecsUSACE
Standards
TransportationRailroadFire SafetyAccessibilityStructural
Tools & References
DiagramsAssembliesProductsCalculatorsChecklistsPermits
PricingLog in
General Provisions (100-199)

1093Table C 240

IN · 2024 Standard SpecificationsBook pages 11001102View official source ↗

Species Groupings for Treatment in Same Charge Group Species A Southern Pine B Coastal Douglas-fir

g.Conditioning

Conditioning shall be in accordance with AWPA Standard T1. h. Inspection During Treatment The treater shall determine that the pres ervatives used are in accordance with the requirements herein. The minimum frequency of the preservation analysis shall be each charge for the occasional single char ge inspected. The minimum frequency for consecutive treatments from the same working tank shall be the first and at least one of every five additional charges, selected at random. Preservative samples shall be 250 taken as appropriate to be representative of the solution in the treating cylinder.

i.Retentions The minimum retentions shall be in accordance with AWPA Standards T1 and

U1. j . P e n e t r a t i o n The penetration requirements shall be in accordance with AW PA Standard T1, table B6. 260

k.Inspection After Treatment Following treatment, the charge shall be physically inspected in accordance with

AWPA Standard M2, section 4. All treated material shall bear the quality mark of the inspection agency. All inspections shall be completed at no cost to the Department. All non-compliant material shall be removed from the remaining acceptable material before shipment.

l.Branding All post and blockouts shall be clearly and permanently branded or marked on 270

one of the wide faces. The brand shall be within 12 in. of the top of the post. The brand shall show the treater’s identification, the plant designation, and the year of treatment. The month may also be included. The brand shall also show the species, the preservative type, and retention, all in accordance with AW PA Standard M6.

m.Conformance

The treating plant supplying the material shall be responsible for and will be required to supply a certificate indicati ng the species, grade, preservative type, retention, year, and name of treater. The certificate shall also include all of the other information listed in AWPA Standard M2, section 6.2. 280 911.02 1094 n. Records Copies of treating records, analysis records, and other records which may be necessary to determine accordance with specifications shall be made available to Department personnel or their designated representatives upon their request. Required information shall be that which is listed in AWPA Standard M2, section 6.2. These records shall be retained by the treating plant for five years from the date of material shipment.

o.Independent Inspections 290

The Department may inspect the material or call for a non-Departmental inspection to verify that it is in accordance with all specifications. 4. Field Treatment of Posts and Blockouts Cuts, holes, or injuries to the surface of posts and blockouts which occur after pressure treatment shall be field treated with copper naphthenat e in accordance with AWPA Standard M4. 5. Rejection for Degrade After Treatment Guardrail posts or blockouts developing the following degrade prior to installation 300 will be rejected regardless of prior approvals:

a.single checks greater than 3 in. deep or checks opposite each

other totaling more than 3 in. deep, measured with a probe not more than 1/16 in. thick,

b.single checks 1/4 in. wide or wider measured at the widest

point, and extending more than 1/3 of the length of the post or blockout, 310

c.single checks greater th an 3/8 in. wide measured at the

widest point,

d.splits greater than 3 in. long which are in the plane of the

bolt hole,

e.crooks or bows exceeding 1 in. per 10 ft length; and all

twists,

f.combinations of checks, splits, or shakes which are 320

otherwise in accordance with th e specifications but which may cause the post or blockout to separate into several pieces.

(g)Recreational Applications

Lumber and timber that will be used in facilities where human contact will occur, such as handrails, pedestrian facilities including decking and picnic tables, shall be 911.02 1095 treated in accordance with AWPA Standards U1 or UC4A, or AASHTO M 133. A Type C certification in accordance with 916 shall be provided for the lumber/timber. 330

(h)Preservatives Preservatives shall be in accordance with current AWPA or AASHTO M 133

Standards as modified by EPA regulation. Waterborne preservatives shall be in accordance with AASHTO M 133 or AWPA Standards.

Source: Indiana Standard Specifications, 2024 Edition. Pages 11001102 of 1,248.