ANTI-GRAFFITI CONCRETE COATING

PART 1 GENERAL

1.1SECTION INCLUDES

A.Concrete surface preparation and application of a non-sacrificial

anti-graffiti coating applied to concrete surfaces treated with penetrating concrete sealer or concrete coating.

1.2RELATED SECTIONS Not Used

1.3REFERENCES

A.ASTM D 3960: Determining Volatile Organic Compound (VOC) Content

of Paints and Related Coatings.

B.ASTM D 7089: Determination of the Effectiveness of Anti-Graffiti Coating

for Use on Concrete, Masonry and Natural Stone Surfaces by Pressure Washing.

1.4DEFINITIONS

A.Barrier Coat – a primer required by the manufacturer to cover surface

treatments that are incompatible with the anti-graffiti coating.

B.Non-sacrificial Anti-graffiti Coating – a coating that remains intact and

undamaged after the removal of graffiti from a concrete, masonry or natural stone surface.

1.5SUBMITTALS

A.Manufacturer’s product data, warranty information, recommended

installation instructions, and graffiti removal instructions for review.

B.Three 8½ inch by 11 inch samples of each anti-graffiti coating color

required on the project for approval before ordering anti-graffiti coating materials if solid opaque color is required.

C.Compatibility letter from the manufacturer, for information, indicating anti-

graffiti coating is compatible with previous coatings.

Anti-Graffiti Concrete Coating

PART 2 PRODUCTS

2.1ANTI-GRAFFITI COATING

A.Permanent non-sacrificial anti-graffiti coating.
B.Meet Cleanability Level 1 according to ASTM D 7089.
C.Meet VOC content of 100 g/L or less. Refer to ASTM D 3960.
D.Color
1.Use a transparent clear coating that does not alter the color of the

underlying surface finish when applying over a colored concrete coating.

2.Use solid opaque color when applying over a clear penetrating

concrete sealer.

E.Use a coating compatible with the penetrating concrete sealer or concrete

coating used.

1.Include barrier coat when required by manufacturer.

PART 3 EXECUTION

3.1PREPARATION

A.Apply only to surfaces that have been sealed with a penetrating concrete

sealer or concrete coating.

B.Remove fence, signs, reflectors, railings, and similar items already in

place that are not to be coated.

1.Protect items in place before surface preparation and coating if

removal is impractical because of the size or weight of item.

2.Reinstall removed items after completing anti-graffiti coating

installation.

C.Clean substrates of substances that could impair the coating bond before

applying coating.

1.Schedule cleaning and coating application so dust and other

contaminates from cleaning process will not fall on wet, newly coated surfaces.

2.Clean and prepare surfaces to be coated according to the

manufacturer’s written instructions for substrate condition.

a.Remove efflorescence, chalk, dust, dirt, grease, oils, release

agents, and curing compounds. Anti-Graffiti Concrete Coating

D.Remove existing coatings or apply a barrier coat as recommended by the

manufacturer when applying an anti-graffiti coating to an existing surface with an unknown or incompatible sealer or coating.

1.Apply penetrating concrete sealer or concrete coating that is

compatible with anti-graffiti coating when existing coating is removed.

3.2GRAFFITI TEST

A.Apply graffiti to two 3 ft by 3 ft test areas selected by the Engineer.
1.Make treated areas sufficiently larger than test areas to prevent

graffiti from marking uncoated surfaces.

2.First test area.
a.Apply solvent based spray paint.

1) Paint using colors black, blue, and red until the test area is completely covered.

3.Second test area.
a.Apply solvent based ink markers.

1) Mark the surface using black, blue, and red colors.

b.Provide marker coverage sufficient to demonstrate the

performance of the anti-graffiti coating.

4.Do not apply anti-graffiti coating to entire surface until the Graffiti

Test has been completed and the Engineer is satisfied with the results.

B.Remove the graffiti in the presence of the Engineer at least five days after

the graffiti application.

C.Consult the manufacturer to determine corrective measures or select

another product if the graffiti is not completely removed.

3.3APPLICATION

A.Do not apply anti-graffiti coating until the penetrating concrete sealer or

concrete coating has properly dried.

B.Apply anti-graffiti coating only when the surface to be coated and outside

air temperature will remain above 45 degrees F for 24 hours.

C.Apply anti-graffiti coating according to manufacturer’s recommended

installation instructions.

END OF SECTION

Anti-Graffiti Concrete Coating

Get an email when 09982 changes

Utah revises spec sections through supplementals and new editions. We check this one every week and email you the day it changes. Free, no account.

Source: Utah Standard Specifications for Road and Bridge Construction, 2026 Edition. Pages 1200–1202 of 1,331. View official source ↗

Ask about this section

Scoped to Utah Standard Specifications, Section 09982 — Anti-Graffiti Concrete Coating. Every answer cites the section it came from, with a verification date — don’t trust a percentage, click the citation.