Effective with the December 2018 Letting 288 2019 Standard Spec ifications Section 516 Waterproofing
516.1Description
surfaces of structures.
516.2Materials
516.2.1 Dampproofing
ASTM D43 .
manufacturer-approved primer. 516.2.2 (Vacant) 516.2.3 Rubberized Membrane
least 60 mil thick. 516.3 Construction 516.3.1 General
concrete temperature is below 45 F, unless the engineer specifi cally allows.
before applying dampproofing or waterproofing.
contaminants, dust, or ot her loose material.
kettle with an armored thermometer. Do not heat asphalt above 3 50 F or coal-tar pitch above 250 F. 516.3.2 Dampproofing
emulsified asphalt.
Apply the primer to thoroughly and uniformly coat the concrete surface. Apply the finish coat after the prime coat cures but is still tacky to the touch.
primed surface. Use n o less than 4 1/2 gallo ns, for each 100 sq uare feet of surface, of asphalt, coal- tar pitch, or emulsified asphalt. 516.3.3 Rubberized Membrane
preformed rubberized asphalt and plastic film membrane, and col d-applied rubberized asphalt mastic.
the rate of 250 to 350 square fee t per gallon. Let the primer dry one hour or until tack free. Re-prime primed surfaces not c overed within 36 hours. Do not prime dense surfaces like metal, but ensure it is clean, dry, and free of grease, oil, dust, or other contaminants.
joints and double cover intersections to eliminate butt joints in the membrane. Chamfer or round the exterior corners.
them with mastic next to seams a nd protrusions after applying t he membrane.
placed in any day's operation and to all outside edges of membr ane after placing the membrane.
discontinuities with membrane and place any required backfill m aterial against the membrane. Backfill within 30 days of installation o r otherwise protect from ultra violet radiation.
Effective with the December 2018 Letting 289 2019 Standard Spec ifications 516.4 Measurement
completed, measured as the length of concrete joint sealed times the plan width of membrane with no additional allowance for overlap at joints and intersections.
516.5Payment
items: ITEM NUMBER DESCRIPTION UNIT
516.0100 Dampproofing SY
516.0500 Rubberized Membrane Waterproofing SY
materials; for applying prime c oats, mastic, and asphalt, coal- tar pitch, or emulsified asphalt; and for placing preformed membrane.
Effective with the December 2018 Letting 290 2019 Standard Spec ifications Section 517 Paint and Painting
517.1Description
including structural steel, misc ellaneous metal or lumber, or t imber parts of other structures. This work also includes, unless specified otherwise in the contract, prep aring surfaces for painting, applying paint, protecting and drying the paint coatings; protecting traffic and property upon and in the vicinity of the structure; and pr otecting of all portions of the structure against disfigurement by paint or paint materials.
coating system on new structural steel; the field cleaning and repair of surfaces field welded or damaged in shipping, handling and er ecting the structural steel ; and providing a field-applied urethane top coat on exterior girders.
517.2Materials
517.2.1 General Requirements
named.
directs.
to a smooth, uniform paint of good brushing consistency that dr ies without streaking, wrinkling, running, or sagging if painted on smooth, vertical surfaces. Pr ime and undercoats shall dry to a dull gloss, and finish coats to a full gloss. If required, colors and hiding powers shall equal those of samples the department furnished . Any proportions specified in formulae are by weight, unless indicated otherwise in the requirements for specific paint. 517.2.2 Containers
capacity metal containers, except for the fractional parts of u nits. Package the fractional parts in one US standard-gallon capacity metal containers. If mechanical mea ns for mixing and stirring are provided at the job site or painting facility, then the contrac tor may furnish the paint in 30 gallon or other suitable size metal containers.
the date of manufacture. Use tight -fitting covers on the contai ners and arrange them so that the inspector may attach wire-lead seals.
more than 15 gallons capacity. 517.2.3 Inspection, Sampling, and Testing
sample the paint at the fabricating shop or in the field. The engineer will obtain samples of paints purchased directly by the state, either for approval at their p oint of manufacture, or at their destination as indicated, either at the time c ontracts are awarded, or in t he invitation for bids.
formulae required to determine the ingredients before making th e paints. The manufacturer shall allow the inspector to check the make up and grinding of paint batches and shall allow test sampling of any or all batches. The manufacturer also shall furnish, if requested, any formulae required to determine specification conformance.
container chosen at random from each lot or batch for each coat , or if a batch or lot exceeds 500 gallons, one container for each 500 gallon increment or fractio n thereof, as repres entative. Take a one-pint sample from the represen tative container in the inspec tor’s presence. It is the contractor or manufacturer’s responsibility to ensure paint mixing occurs in a container that allows sampling of the paint it contains. Take field samples only from paint that is o n the job. Take samples in fabricating shops from containers of paint pro posed for the specific bid it em of work.
any single formulation required for each project, provided the paint purchased is from stock that demonstrated a satisfactory service record.