Effective with the December 2018 Letting 417 2019 Standard Spec ifications Section 635 Structural Steel Sign Supports
635.1Description
635.2Materials
stubs according to ASTM A123 after completing cutting, drilli ng, punching, and welding. Fur nish mill inspection and testing certifications for posts and stubs confo rming to 506.3.21 .
washers all hot-dip galvanized according to ASTM A153 supplemented by ASTM F2329.
635.3Construction
635.3.1 Structural Steel Sign Supports
concrete footings conforming to 636.
the plan details specify. Use a c alibrated torque wrench to establish the final required torque.
cuts and other areas of damaged zinc coating with 2 coats of zi nc dust/zinc oxide paint. Clean damaged and adjacent areas by sanding, scraping, chipping, or wire brushing before painting.
1.1, Structural Welding Code - Steel. Do not weld in the field without the engineer's written approval. The engineer will only allow field welding for repairs in noncr itical locations and when a department- approved individual competent to perform inspections is present during the welding. Perform field welding using personnel qualified under AWS D 1.5, Bridge Weldi ng Code. 635.3.2 Replacing Base Connection Bolts
details. Repair or replace existing posts, base plates, and stiffener plates damaged during bolt replacement.
635.4Measurement
measured using the pay weights the plan details show.
location acceptably completed.
635.5Payment
items: ITEM NUMBER DESCRIPTION UNIT
635.0200 Sign Supports Structural Steel HS LB
635.0300 Sign Supports Replacing Base Connection Bolts EACH
including base connection bolts , nuts, and washers. The departm ent will pay separately for concrete footings under 636.5 and for signs under 637.5 .
bolts for each contract designated sign; and for repairing dama ge done during bolt replacement.
Effective with the December 2018 Letting 418 2019 Standard Spec ifications Section 636 Concrete Sign Supports
636.1Description
constructed under 635 and for sign bridges and overh ead sign supports constructed un der 641.
636.2Materials
Provide QMP for class II ancilla ry concrete as specified in 716.
636.3Construction
636.3.1 General
portions of concrete footings as specified in 502.3.8.1 . Wait until the concrete has attained 3500 psi compressive strength or 7 equivalent days as specified in 502.3.10 before erecting any portion of the structure on the footing.
and after installing t he sign or signs they are at the position, elevation, and orientation the plans, and specifications specify, o r as the engineer directs.
the rod next to the support or as the engineer directs. 636.3.2 Excavation
the vicinity and conduct operations to avoid damaging them.
636.3.3 Placing Concrete
specified otherwise below.
extends above the ground.
hardens. Protect anchor rod threads above the top of the foundation level from concrete splash.
place construction joints w ithout the engineer's written approval. Line the upper 18 inches with a disposable casing to ensure a uni form diameter. Remove the disp osable casing before backfilling. For the upper surface, provide a level plane finished true to grade .
necessary to shut off seepage wate r, then line the remaining de pth of the footing shaft with a suitable casing. Ensure casings are of a mple strength to withstand handling stresses, concrete pressure, and the pressure of surrounding so il materials. If removing the casings, withdraw them while placing the footing concrete or immediately following concrete operations. If removing the casing during the concrete operation, place at least 2 feet of concrete before st arting to pull the casing, and maintain a head of concrete of from one to 2 feet during the pulling operation. Take care when pulling the casing to prevent moving the stub posts or anchor rod assembly, reinforcement steel, and upper casing, and to prevent any appreciable quantity of soil from mixing with th e concrete.
636.3.4 (Vacant) 636.3.5 Clean-Up
or discarded materials, and restore work or property damaged during operations.