B
HomeLibrariesCopilotSearchProjectsBookmarks
FeedbackHelp Desk
Libraries
Building Codes
Code LibraryIBC — BuildingIRC — ResidentialIFC — FireIPC — PlumbingIMC — MechanicalIFGC — Fuel GasIECC — EnergyNEC — ElectricalModel Codes
Specifications
CSI SpecificationsDOT SpecsTransit SpecsUSACE
Standards
TransportationRailroadFire SafetyAccessibilityStructural
Tools & References
DiagramsAssembliesProductsCalculatorsChecklistsPermits
PricingLog in
General

817surface areas the same way. Ensure that treatment reports, boring reports, and assay

WY · 2021 Standard SpecificationsBook pages 00View official source ↗

reports submitted to the department are representative of each shipment. 6 Ensure the provision and use of timber and lumber that has been inspected by an

American Lumber Standard Committee (ALSC) accredited third party agency before shipment, that a certificate of inspection is given to the engineer, and that each piece inspected and certified is marked accordingly; wood to be treated may be unmarked. Ensure that untreated lumber has been seasoned to a moisture content of 20 percent or less before shipment. 7 Certification or grade marking does not constitute acceptance; the engineer will reject

material not meeting specifications upon delivery. 8 Stack wood stored at the job site to ensure proper ventilation and elevated off the

ground; the engineer may reject wood damaged because of improper storage. 9 Provide rough-sawn timber or lumber in accordance with Table 817.1-1, Dimensional

Requirements: Rough-Sawn Timber or Lumber. 10 Provide posts in accordance with Subsection 816.10, Treated-Timber Sign Posts.

Table 817.1-1 Dimensional Requirements: Rough-Sawn Timber or Lumber Allowable Thickness/Width Nominal Thickness/Width in [mm] Minimum(1) in [mm] Maximum in [mm] 1 [25]

⅞ [22]

1⅛ [29]

2 [50]

1⅝ [41]

2¼ [57]

3 [75]

2⅝ [68]

3⅜ [86]

4 [100]

3⅝ [92]

4⅜ [111]

5 [125]

4⅝ [117]

5⅜ [137]

6 [150]

5⅝ [143]

6⅜ [162]

7 [175]

6⅝ [168]

7⅜ [187]

8 [200]

7⅜ [187]

8½ [216]

If the dimension is thickness, 20 percent of the length of the item may have a thickness 1/32 in [0.8 mm] smaller than the indicated minimum tolerance for rough sawn lumber; ensure that the remaining 80 percent of the item length meets specified minimum thickness. (1)

748

Mailbox Posts and Mounting Hardware

818.1Mailbox Post and Mounting Hardware

1 Ensure the provision and use of mailbox posts and mounting hardware in accordance

with Table 818.1-1, Mailbox Post and Hardware Mounting Requirements. Table 818.1-1 Mailbox Post and Hardware Mounting Requirements Item

Size

Material Type

Surface Finish

U-Bolt Clamps

Commercial

Hardware

Commercial

ASTM A 153 [ASTM A 153M], ASTM A 275 [ASTM A 275M]

2 in [50 mm] OD 14 gage

ASTM A 513

ASTM A 275 [ASTM A 275M], ASTM A 653 [ASTM A 653M], ASTM A 924 [ASTM A 924M]

Socket

12 gage

ASTM A 569 M

Dip-coated with rust-inhibiting primer; Fed Spec TT-P-636

Wedge

12 gage

ASTM A 569 M

ASTM A 275 [ASTM A 275M], ASTM A 653 [ASTM A 653M], ASTM A 924 [ASTM A 924M]

Mounting bracket and angle

14 gage

ASTM A 366 M

ASTM A 275 [ASTM A 275M], ASTM A 653 [ASTM A 653M], ASTM A 924 [ASTM A 924M]

Adapter plate

12 gage

ASTM A 366 M

ASTM A 275 [ASTM A 275M], ASTM A 653 [ASTM A 653M], ASTM A 924 [ASTM A 924M]

Anti-twist plate

16 gage

ASTM A 366 M

Single, double, multiple supports

Cantilever pipe, galvanized. Pressure testing not required

ASTM A 53 type ASTM A 275 [ASTM A 275M], ASTM A 653 F, Schedule 40 [ASTM A 653M], ASTM A 924 [ASTM A 924M]

Screw fittings may be steel or malleable iron. Pressure testing not required.

ASTM A 858M or ASTM A 47 [ASTM A 47M] grade 22010

749

ASTM A 153 [ASTM A 153M] class C or D

Grout

819.1Grout

819.1.1 Sand-Cement Grout

For sand-cement grout, provide and use grout composed of portland cement in accordance with Subsection 801.1, Portland Cement, sand in accordance with Subsection 803.3, Aggregate for Mortar, and only enough water to allow placing and packing; ensure a proportion of cement to sand, measured by volume, of 1:2. Mix approximately 45 minutes before use. 819.1.2 Cementitious Grout 1 Provide and use a product in accordance with ASTM C 1107.

819.2Epoxy Resin Grout

1 For epoxy resin grout, provide and use a product in accordance with Table 819.2-1.

Description

Table 819.2-1 Epoxy Grout Properties Value 2-Component

Compressive Strength Compressive Modulus Tensile Strength Gel Time Linear Shrinkage on Cure Coefficient of Thermal Expansion

> 15,000 psi at 48 hours > 2,500,000 psi at 7 days > 3,500 psi at 7 days 45 - 90 minutes < 0.03%, Non-expansive < 20 x 10-6 in/in-F

Standard ASTM C579 ASTM C579 ASTM C307 ASTM D2471 ASTM C531 ASTM C531

3-Component Compressive Strength Compressive Modulus Tensile Strength Gel Time Linear Shrinkage on Cure Coefficient of Thermal Expansion

> 11,000 psi at 48 hours > 1,800,000 psi at 7 days > 2,500 psi at 7 days 90 - 240 minutes < 0.01%, Non-expansive < 18 x 10-6 in/in-F

750

ASTM C579 ASTM C579 ASTM C307 ASTM D2471 ASTM C531 ASTM C531

Hydrated Lime

820.1General

1 For

hydrated lime, provide and use a product in accordance with AASHTO M 303, Type I.

820.2Soil Stabilization

1 For use in soil stabilization, provide and use hydrated lime in accordance with AASHTO

M 216.

751

Vacant

752

Rockfall Mesh

822.1Wire Mesh

1 Provide rockfall mesh, consisting of 8 x 10 double twist hexagonal netting, zinc and PVC

coated in accordance with ASTM A975. Ensure the minimum mesh wire diameter is 0.106 in [2.7 mm] with a maximum tensile strength of 70 ksi [483 MPa] per ASTM A641 for soft temper steel. Ensure mesh characteristics and minimum strength requirements meet the requirements of Tables 1 and 2 in ASTM A 975 for PVC and metallic coated gabion materials. 2 Provide rockfall mesh that is hexagonal, non-raveling, woven, double-twist, hot-dipped,

zinc-coated galvanized wire, with the size of the mesh opening being 3¼ in × 4½ in [83 mm × 114 mm], nominal. Match the color of the rockfall mesh shown in the contract and as approved by the engineer. 3 Selvedge or bind perimeter edges of wire mesh to prevent unraveling of the mesh.

Use wire with a minimum strength at least equal to the mesh for the selvedge and with a diameter greater than that of the mesh wire and as recommended by the manufacturer. 4 Ensure rockfall mesh meets the requirements listed in Table 822.1-1, Rockfall Mesh

Properties. Table 822.1-1 Rockfall Mesh Properties Property

Test Method

Nominal Value

Tensile Strength

ASTM A 975

60 ksi [414 MPa]

Galvanized Wire Diameter

ASTM A 975

0.120 in [3.05 mm]

Zinc Coating

ASTM A 975

0.85 oz/ft2 [260 g/m2], min.

Galvanized Wire Diameter (For PVC Coated Wire)

ASTM A 975

0.106 in [2.7 mm]

Zinc Coating (For PVC Coated Wire)

ASTM A 975

0.80 oz/ft2 [243 g/m2], min.

PVC Coating Thickness

ASTM A 975

0.02 in [0.56 mm]

822.2Lacing and Fasteners

Provide and use fasteners for connecting edges and ends of mesh rolls at overlaps in accordance with the requirements of ASTM A 975. Supply lacing wires, fasteners, ties, clips, and connecting wire in sufficient quantity for securely fastening all edges of the rockfall mesh as shown in the contract. Ensure all furnished materials are in accordance with ASTM A975 for PVC and metallic coated gabion materials. Provide and use locking

753

Rockfall Mesh

Source: Wyoming Standard Specifications for Road and Bridge Construction, 2021 Edition. Pages 00 of 771.