619.01Description. This work consists of furnishing, placing, maintaining or replacing

as necessary, removing when no longer applicable and installation at other locations all traffic control devices including pavement marking materials (paint, tape, markers, etc.) in accordance with contract provisions and as directed by the Engineer.

619.02Materials. Certification of traffic control devices shall be in accordance with the

provisions of Subsection 619.02.13.

.1--Painted Traffic Stripe . Painted traffic stripe shall meet the applicable

requirements of Sections 710 and 720. The temporary traffic paint can be waterborne paint or fast dry solvent traffic paint meeting the requirements set out in Section 710. When using fast dry solvent traffic stripe, no paint can be sprayed or placed on the ground during set-up or clean-up.

.2--Pavement Marking Tape . Preformed pavement marking materials must be

listed on the Department's APL and meet the requirements of Subsection 720.05.

.3--Reflective Raised Pavement Markers. Raised pavement markers must be on

the Department's APL and shall meet the applicable requirements of Subsection 720.03.

.4--Construction Signs. Construction signs shall meet the applicable requirements

of Sections 618 and 721 and the following: Sign supports may be steel beams, structural steel pipe, steel U-section posts, 4-inch x 4- inch wood posts, portable easels, or barric ades as required for installation. Breakaway bases shall be provided for all steel beams and pipe posts. Portable sign supports may be used for daylight operations, moving work areas, or other short-term activities. Standards for height of construction signs shall be those shown for roadside signs in Chapter 6F of the MUTCD. Signs mounted on portable supports or barricades may be at lower heights but the bottom of the sign shall be no less than one foot above the traveled way. Unless specified otherwise, fluorescent orange reflective sheeting, meeting the requirements of Subsection 721.06, shall be used on all construction signs regardless of whether used during daytime or nighttime hours. Unless otherwise specified on the plans, the material on which the reflective sheeting is to be applied shall be as a minimum, 16-gauge steel, 0.080-inch aluminum, or 5/8-inch high density overlaid plywood. Ungalvanized st eel, exterior grade plyw ood and lumber shall have a minimum of two coats of paint on front, back, and edges. High density overlaid plywood shall have the edges painted. The material to which reflective sheeting is to be applied shall be prepared in accordance with the recommendations of the sheeting 450 Section 619 Section 619 manufacturer. For new signs, the Contractor shall furnish the Engineer with three certified copies of a statement or test report from the producer indicating that th e signs meet the requirements of the specifications. Previously used signs will be accepted on the basis of reflectivity and legibility. Reflectivity for these signs may be tested by the Engineer in accordance with the procedures set out below or by the Central Laboratory. If tested by the Central Laboratory, the reflective sheeting shall have at least 50 percent of the reflectivity specified for new sheeting. Tests performed in the Central Laboratory will be for reflectance only, and the Contractor shall pay the testing charges. Legi bility in all cases will be determined by the Engineer. The determination for reflectivity and legibility by the Engineer will be made from the driver’s seat of an automobile with the headlamps on low beam between the hours of one hour after sunset and one hour before sunrise at the distance specified below. The signs shall be mounted at the specified height for each type sign as it is being tested. Should the Contractor elect to have the signs tested in place, each sign not meeting the requirements of these specifications shall be immediatel y removed and replaced. The Engineer will certify by letter to the State Materials Engineer that the signs have been tested and accepted under this procedure. A sign will be considered as meeting the reflectivity requirements of this specification when the shape and color of the sign can be unquestionably identified at a distance of 1500 feet from the sign. In cases where grade or alignment will not permit a sight distance of 1500 feet, the distance for specification compliance shall be the furthermost point at which the complete sign becomes visible. If there is a question as to a sign being acceptable, the sign may be sent to the Central Laboratory for verification. Testing charges will be borne by the State when the verification test determines that the sign is acceptable. Legibility will be acceptable when the sign letters and numerals are capable of being read at a distance determined by the following formula: D = 50 H D = Distance in Feet H = Letter/numeral height in inches

.5--Advance Warning Flashing Arrow Panels. Flashing arrow panels shall meet

the requirements of Section 6F.61 of the MUTCD.

.6--Median Barrier and Delineators. New precast concrete median barrier shall

meet the requirements of the plans, contract documents, and Section 615 except the surface may be a Class 1 ordinary surface finish unl ess designated otherwise. When precast concrete median barriers are no longer needed at one location, as determined by the Engineer, the barriers shall be removed and reset at other designated locations. When barriers have to be stored until needed at another location, payment for removing and resetting will not be made until they are reset at their designated location. The Contractor shall furnish the storage area. 451 Section 619 Section 619 The Engineer may allow the installation of used barriers for temporary traffic control upon an inspection and determination that the barrier units are structurally adequate for their intended purpose and they meet the requirements of this Section. Barriers with small chips or fractures not affecting their integrity may be accepted. Precast concrete barriers used on constructi on projects purchased or manufactured after October 1, 2002 must meet the requirements of NCHRP Report 350 or MASH. Precast median barriers purchased or manufactured prior to October 1, 2002 may be used until they complete their normal service life. Certification of precast concrete barriers shall be as required in Subsection 619.02.13. Portable median barrier shall be a highly portable, crashworthy barrier especially designed and used as a temporary barrier on highway construction projects. The barriers shall be designed so that it can be filled with water when in use and be easily drained for moving and transporting. The barrier shall be NCHRP Report 350 or MASH approved for the speed rating indicated on the plans or in the contract documents. The Contractor shall furnish the Engineer th ree copies of the manufacturer's certification stating that the portable median barriers furnished meets the requirements of this Section. Delineators shall be listed on the Department's APL and meet the requirements of the plans and Section 6F.68 of the MUTCD.

.7--Channelization Devices, Barricades, and Warning Lights . Channelization

devices, vertical panels, tubular markers, cones, drums, barricades and temporary raised islands shall meet the requirements of the pl ans and Sections 6F.63 through 6F.75 of the MUTCD. Drums shall be constructed of li ghtweight, deformable material capable of retaining reflective sheeting. Reflective sheeting for drums shall be Type III meeting the requirements of Subsection 721.06. Warning lights shall meet the requirements of Section 6F.83 of the MUTCD. The use of 2-inch nominal thickness timber for rails on Type III barricades has not been approved by NCHRP or MASH as a crashworthy device. Therefore, the use of 2-inch nominal thickness timbers will not be allowed for rails on Type III Barricades. Timber rails for Type III Barricades shall be as follows. • For barricades up to four feet (4’) wide, the maximum thickness of timber rails shall be one inch (1”) and the material shall be pine timber or ¾-inch ACX plywood. • For barricades more than four feet (4’) wide, timber rails shall be constructed of ¾- inch ACX plywood. A list of crashworthy Type III Barricades can be found at the following FHWA website. http://safety.fhwa.dot.gov/roadway_dept/policy_guide/road_hardware/wzd/

.8--Traffic Signals and Flashers . Traffic signals and flashers shall meet the

requirements of the plans and Section 6F.84 & 6F.81 of the MUTCD.

.8.1--Portable Traffic Signals. Portable traffic signals shall be trailer mounted

452 Section 619 Section 619 units that provide for easy transportation and quick setup and deployment. Each unit shall be self-contained. The types of portable traffic signals are as follows. • Type 1 portable traffic signal shall include one signal head that is mounted on the vertical upright of the trailer. • Type 2 portable traffic signal shall include two signal heads per trailer with one signal head mounted on an overhead mast arm that can be extended over the travel lane, and the other signal head shall be mounted on the vertical upright of the trailer. • Type 3 portable traffic signal shall be the same as Type 2 mentioned above but with enhanced capabilities as mentioned in each applicable section below. The portable traffic signals shall be MUTCD Compliant and utilize standard ITE signal heads, and adhere to the ITE Specifications and Standards for Vehicle Traffic Control Signal Heads, Light Emitting Diode (LED) Circular Signal Supplement. The units shall be solar powered and be able to communicate with other portable signals via wireless communications. The unit shall include all the major components listed below or be able to perform the functions of these components. The major components of the unit shall include but are not limited to the trailer, telescoping mast arm (on Type 2), signal head(s) and back plates, traffic signal controller with operating software, solar charging system with batteries, input and output devices, flasher units, conflict monitor, relays, communications system and other equipment required for the safe operation and installation of the unit.

.8.1.1--Signal Heads . The signal heads and all applicable components of the

portable traffic signal shall meet the physical display and operational requirements of conventional traffic signals as specific in the Manual on Uniform Traffic Control Devices (MUTCD). The signal heads shall meet the requirement laid out in the Mississippi Standard Specification for traffic signa l heads and associated MDOT material specifications for traffic signal heads. For Type 1, Type 2 and Type 3 signals, the signal heads shall have the ability to be rotated 180 degrees to face in the opposite direction and shall have the ability to rotate and lock in approximately 10 degree increments to position the signal head for the optimum visibility to motorists. For Type 1 signals, the signal head shall be mounted to the vertical upright of the trailer at a minimum height of eight feet (8') from th e bottom of the signal head unit to the road surface. For Type 2 signals, each unit shall contain two signal heads with one signal head mounted on an overhead mast arm that can be exte nded over the travel lane with a minimum clearance of 17 feet measured from the bottom of the signal head unit to the road surface. The lower signal head shall be mounted to the vertical upright of the trailer at a minimum height of eight feet (8') from the bottom of the signal head unit to the road surface. For Type 3 signals, each unit shall be the same as Type 2 mentioned above but with

enhanced capabilities as mentioned below.

.8.1.2--Controller and Operating Requirements. The portable traffic signal

(Types 1, 2, and 3) shall include a controller that is in compliance with NEMA TS 1

Performance Standard. The controller shall have an easy to read front panel indicator

453

Section 619 Section 619

display for showing and programming the configuration settings and controller status. The

controller shall be capable of operating the portable traffic signal system in a fixed time,

traffic actuated or manual control mode. Each portable traffic signal in a connected system

shall have the capability to serve as either the master or remote signal. Each portable traffic

signal shall include a Conflict Monitor Unit (CMU), or Malfunction Management Unit

(MMU)to ensure phase conflicts do not exist during operation.

For Type 1 and Type 2 signals, a minimum of five (5) automatic time-of-day timing plans

within a 24-hour period should be available in fixed time mode. The operating system

should have the ability to control a minimum of four (4) traffic phases with programmable

cycle time adjustments and user adjustable red, amber, minimum green and maximum

green times. The operating system shall also have the capability of facilitating standby

modes of red, red flash and yellow flash.

For Type 3 signals, a minimum of ten (10) automatic time-of-day timing plans within a 24-

hour period should be available in fixed time mode. The operating system should have the

ability to control a minimum of 16 traffic phases with programmable cycle time

adjustments and user adjustable red, amber, minimum green and maximum green times.

The operating system shall also have the capability of facilitating standby modes of red,

red flash and yellow flash.

The system shall also have the ability to operate in vehicle actuation mode when vehicle

detectors are used. The operating system shall have the capability to allow the Portable

Traffic Signal to be connected to and controlled by a standard NEMA controller.

The system shall have the capability to be configured and controlled remotely using a

flagger radio remote control at a distance up to ¼ mile from the master.

The system shall have the capability of remote monitoring for reporting, at a minimum,

signal location and status, battery voltage and system defaults. The remote monitoring

shall have capability to alert designated individuals if a fault condition occurs.

The operating system shall include password protection to prevent unauthorized

programming.

.8.1.3--Wireless Communications. The portable traffic signals shall communicate

with other portable traffic signals in the system via license-free wireless 900 MHZ radio

link communications as specified in Subsection 662.02.2 of the radio Interconnect System

specification. The radio units shall maintain communications at a minimum distance of

one (1) mile. The radio system shall conform to the applicable Federal Communications

Commission requirements and all applicable state and local requirements.

The portable traffic signals shall be in direct communication at all times either by wireless

or hardwire connection to provide for the required conflict monitor.

.8.1.4--Power Requirements. The portable traffic signal shall be equipped with a

solar power array, charging unit and battery system. The number and size of batteries shall

be sufficient to operate the Type 1 and Type 2 signals for a minimum of 21 days and Type

3 signals for minimum of 30 days without additional charging or assist from the solar array.

An on-board battery charger shall be compatible with both the solar array and with a 120V

AC power source.

454

Section 619 Section 619

For Type 1 and Type 2 signals, the solar panel array shall provide for a minimum of 440

watts of solar collection capability.

For Type 3 signals, the solar panel array shall provide for a minimum of 480 watts of solar

collection capability and shall include a tilt and rotate system to optimally position the

panels.

All instrumentation for the electrical system and battery compartment shall be mounted in

a lockable weatherproof enclosure. Solar panels shall be secured to the mounting brackets

for theft prevention.

.8.1.5--Trailer and Lift System. For Type 1 and Type 2 signals, the trailer and all

mounted components shall conform to the wind loading requirements of 80 mph minimum

as described in the AASHTO Standard Specifications for Highway Signs, Luminaries and

Traffic Signals. For Type 3 signals, the trailer and all mounted components shall conform

to the wind loading requirements 90 mph minimum as described in the AASHTO Standard

Specifications for Highway Signs, Luminaries and Traffic Signals. The trailer shall be

made of structural steel and shall include four (4) leveling/stabilizer jacks capable of lifting

the trailer a minimum of six inches (6”).

The trailer shall be equipped with a hydraulic or electric lift system sufficient for one

person to be able to raise and lower the vertical upright and/or horizontal mast arm to and

from the operating position.

For Type 2 and Type 3 signals, the trailer shall be equipped to provide legal and safe

transport on the public highway system at speeds up to 55 mph.

All exterior metal surfaces, except signal heads and back plates, shall be powder-coat

painted highway safety orange.

.9--Impact Attenuators. Impact attenuators must be listed on the Department's

“Approved Sources of Materials”.

Approved impact attenuator systems shall meet standardized testing defined in NCHRP

Report 350 or MASH. In addition, documentation from FHWA must accompany the

devices, indicating that the devices meet the appropriate crash test criteria and can be used

on the National Highway System (NHS). Prior to installation, the Contractor shall provide

two copies of the manufacturer’s installation details to the Project Engineer. The Project

Engineer shall keep one copy in the project file and provide one copy to District

Maintenance Engineer. The installation details shall be engineering drawings, a minimum

of 11"x17" in size. Reflective adhesive sheeting with alternating black and yellow stripes

(sloping downward at an angle of 45 degrees in the direction traffic is to pass) shall be

required on the end of the attenuator section. The type of system installed shall be written

on the device with a Permanent Marking Stick or some other means of permanent

identification.

When an impact attenuator is no longer needed at one location, as determined by the

Engineer, the attenuator shall be removed. When the contract documents contain

provisions for the removal and resetting of impact attenuators, the attenuator shall be

removed and reset at other designated locations. When an impact attenuator is stored until

455

Section 619 Section 619

needed at another location, payment for removing and resetting will not be made until the

attenuator is reset at the designated location. The Contractor shall furnish the storage area.

Replacement Packages. Replacement packages shall consist of spare parts of the expected

type and number needed to repair one hit for every three attenuators in place.

.10--Temporary Guardrail. Temporary guardrail shall meet the requirements of

the plans and the applicable requirements of Sections 606 and 712.

.11--Snap-Back Delineators. Snap-back delineators shall be selected from the list

of surface mounted flexible delineator posts as shown on the Department's "Approved

Sources of Materials".

.12--Terminal End Section. Terminal end sections, installed as per manufacturer’s

recommendations, must meet the requirements of NCHRP Report 350 or MASH. When

specified in the plans, the terminal end sections shall be the type specified, unless otherwise

approved by the Engineer.

Terminal end sections shall be Flared or Non-Flared and shall be one listed on the

Department’s APL. The end sections shall be installed in accordance with the

manufacturer’s recommendation. Prior to installation, the Contractor shall provide two

copies of the manufacturer’s installation details to the Project Engineer. The Project

Engineer will keep one copy in the project file and provide one copy to the District

Maintenance Engineer. The installation details shall be engineering drawings, a minimum

of 11” X 17” in size. Reflective adhesive sheeting with alternating black and yellow stripes

(sloping downward at an angle of 45 degrees in the direction traffic is to pass) shall be

required on the end of the terminal section. The type of terminal section installed shall be

written on the device with a Permanent Marking Stick or some other means of permanent

identification.

.13--Certification of Traffic Control Devices. The Contractor will be required to

certify that the traffic control devices used on the project meets certain requirements. The

traffic control devices shall be certified in accordance with the following requirements:

Category 1 Traffic Control Devices. Category 1 traffic control devices are defined as low-

mass, single-piece traffic cones, tubular markers, single-piece drums with or without lights

and hardware, and delineators.

The Contractor shall certify to the Project Engineer by a letter ONLY stating that the

Category 1 traffic control devices, furnished and used, meet the requirements of NCHRP

Report 350 or MASH.

All documentation supporting the certification is to be kept on file by the Contractor subject

to review by the Department at any time. Support documentation shall be kept on file for

two years after the completion of the project.

The Contractor may self-certify Category 1 Traffic Control Devices. In order to make the

self-certification, the Contractor shall have as a minimum the following support

documentation regarding the certification:

456

Section 619 Section 619

1.A title, e.g., "Certification of Crashworthiness";
2.Name and address of vendor making the certification;
3.Unique identification of the certificate such as serial number, with numbered

pages and the total number of pages;

4.Description and unambiguous identification of the item tested;
5.Identification of the basis for self-certification process used and to what test level

of NCHRP Report 350 or MASH. This basis as crash test experience with similar

devices or years of demonstrably safe operational performance;

6.A signature and title, or an equivalent identification of the person(s) accepting

responsibility for the content of the certification, however produced, and the date

of issue;

7.A statement that the certification shall not be reproduced except in full.

All documentation supporting the self-certification is to be kept on file by the Contractor

subject to review by the Department at any time. Support documentation shall be kept on

file for two years after the completion of the project.

The Contractor's letter to the Project Engineer shall state that all Category 1 traffic control

devices, furnished and used, meet the requirements of NCHRP Report 350 or MASH.

Category 2 Traffic Control Devices. Category 2 traffic control devices are defined as

barricades with or without lights and signs, intrusion detectors, vertical panel assemblies,

portable sign supports, drums with warning lights, and cones with warning lights not

meeting Category 1.

The Contractor shall certify to the Project Engineer by a letter ONLY stating that the

Category 2 traffic control devices, furnished and used, meet the requirements of NCHRP

Report 350 or MASH. The Contractor's letter shall state that all Category 2 traffic control

devices, furnished and used, meet the requirements of NCHRP Report 350 or MASH.

Category 3 Traffic Control Devices. Category 3 Traffic Control Devices are items similar

to Category 2 but weigh more than 100 pounds. Category 3 Traffic Control Devices

include concrete barrier, portable barriers, truck mounted attenuators (TMAs), work zone

crash cushions, and fixed sign supports.

Category 3 traffic control devices, furnished and used, must meet the requirements of

NCHRP Report 350 or MASH. The Contractor shall furnish a letter ONLY certifying that

the Category 3 traffic control devices meet the requirements of NCHRP Report 350 or

MASH.

.14--Changeable Message Sign. This work shall consist of furnishing, testing, and

maintaining a trailer-mounted electronic Portable Changeable Message Sign (PCMS)

assembly. The sign display shall be a LED, full matrix sign. If more than one portable

changeable message sign is required for this project, they shall all be of the same model

and from the same manufacturer. All parts and materials used to construct the portable

changeable message signs shall be interchangeable.

The PCMS shall be a trailer-mounted, solar powered, portable changeable message sign.

457

Section 619 Section 619

Each PCMS shall include the following main components:

a.Sign Housing
b.LED Modules
c.LED Drivers
d.Battery Bank
e.Sign Controller
f.Trailer
g.AC Charger
h.Solar Panel
i.Solar Panel Charger

The LED display shall be a full matrix sign with a minimum of 28-pixel rows x 50-pixel

columns. The pixel spacing shall be such that three (3) lines of text (5 columns x 7 rows,

8 characters) shall each have a nominal height of 18 inches.

The PCMS shall include a remote communications interface as specified herein. The

PCMS shall be provided with a local serial and USB connection within the sign control

cabinet so that a laptop computer using the remote software can communicate directly with

the sign CPU.

This subsection incorporates normative references to other standards as outlined in Section

1 of the NEMA TS-4 standard and as listed below.

NEMA TS4-2004, Hardware Standards for Dynamic Message Signs (DMS) with NTCIP

Requirements. All NEMA TS-4 requirements that are applicable to portable signs shall

be used.

NTCIP Standards.

If a conflict exists between the standards referenced and this Specification, this

Specification shall govern.

The definitions of the terms used within this Specification are as defined in Section 1 of

the NEMA TS-4 standard.

If required in the contract, the PCMS shall include a speed radar unit as specified herein.

.14.1--Mechanical Construction. Each PCMS shall meet the following minimum

requirements.

Weather-Tight Enclosure. The entire sign and trailer assembly, including each component

/ equipment exposed to weather, shall be fully protected. It shall withstand the effects of

sand, dirt, dust, moisture, hose-directed water, ice, snow and UV radiation (UVA and

UVB). It shall withstand the effects of high wind loading and blowing rain as specified

herein with all outriggers and/or leveling jacks in place. The sign and all components shall

be watertight. Space shall be provided for manuals to be stored in a weatherproof

environment.

Wind Loading. Wind loading requirements for the portable sign housing and trailer

assembly shall be as specified in Section 3.3.2.1.2 of the NEMA TS-4 standard.

458

Section 619 Section 619

Welding. All welding on all major structural components (aluminum or steel) shall be

performed by certified welders and in accordance with SAE/AWS D8.8 American Welding

Society.

Protective Coatings. Protective coatings or processes, such as anodizing, e-coating,

powder coat painting, plating, etc., shall be incorporated to protect all sign, cabinet, and

trailer metal surfaces from corrosion. Any non-protected metallic fasteners shall be made

of stainless steel or aluminum. All components shall be of similar material, or be isolated

to reduce galvanic reactions.

Temperature and Humidity. Each PCMS shall be designed to operate continuously in

extreme ambient temperature ranges and at high humidity levels.

Operating ambient temperature range of the portable sign and trailer assembly shall be -

29°F to +165°F. Storage temperature range shall be from -40°F to +185°F. The portable

sign shall be capable of continued operation within the operating temperature ranges

specified without the need for active systems (i.e., fans). Operating relative humidity level

of the portable sign shall be up to 95% non-condensing.

Sign Face. Sign face material shall be protected by a non-glaring polycarbonate material

of at least ¼-inch thickness. It shall be replaceable and manufactured of material rated for

outside use and resistant to UV degradation (exposure to the sun).

All electronics and pixels shall be protected from damage due to moisture.

Sign Housing Construction. The portable sign housing, including its front face panels,

shall be designed to conform to the requirements of minimum NEMA Type 3R, as

described in the latest edition of NEMA 250.

It shall comply with the latest structural AASHTO requirements.

It shall be constructed of aluminum sheeting that shall not be less than 1/8-inch thick with

all seams continuously welded by the inert gas process.

The front of the sign housing shall have a flat black matte finish.

Weep holes shall be provided in the housing to allow moisture from condensation to

escape.

The sign housing and cabinets shall be designed to keep insects out.

The sign housing shall be constructed in such a manner as to prohibit stray light from

reducing legibility.

All sides of the sign housing shall have a maintenance-free finish.

Alignment of the sign housing shall be capable of being horizontally adjusted to position

the sign a full 360 degrees. It shall be capable of rotating and locking at any selected

horizontal angle up to 360 degrees. A sight alignment tube/device shall be mounted to

459

Section 619 Section 619

horizontally position the sign display. A positive brake assembly with lockable control

arm shall be provided to position the sign display in the desired position.

It shall allow easy access to all components contained within the display housing without

the removal of any external parts. Door locks shall be rigidly mounted. Gasketing shall

be provided on all door openings and shall be dust-tight, permanently bonded to the door

metal, and shall not stick to the mating metal surface. A gasket channel shall be provided

to support the gasket on the door.

Trailer. Each PCMS trailer shall meet all requirements for trailers as outlined in Section

3.3.3 of the latest NEMA TS-4 standard as well as the following minimum requirements.

(a)All trailers shall meet the requirements of FMVSS, Part 571 and SAE J684 for

transport safety including, but not limited to the use of brakes, safety chains,

coupling device, and lights. PCMS manufacturer shall provide instructions stating

procedures necessary to ensure safe transport.

(b)The structural frame shall be capable of supporting the gross vehicle weight (GVW)

load of the trailer corresponding to the axle and tire ratings in accordance with

FMVSS, Part 571.

(c)The tires shall be radial ST “Special Trailer” rated. The wheels shall be 15-inch

steel wheels with five lug bolts per wheel. Each trailer wheel shall be equipped with

one locking lug nut. A minimum of four keys for the locking lug nuts shall be

supplied for each trailer.

(d)The trailer shall be provided with a minimum of four outriggers or leveling jacks.

One outrigger or leveling jack shall be mounted near each corner of the trailer. The

length of the leveling jacks shall be such that when the trailer is level, all four jacks

and the tongue jack can be lowered into the vertical position. The jacks shall be

screw type jacks with a minimum 25-inch lift. Each jack shall include a swivel

mechanism that allows the jacks to swing up to a horizontal position for towing.

The swivel mechanism shall secure the jack in both vertical and horizontal positions

through a lock pin.

(e)The trailer shall also be provided with a trailer stand mounted on the tongue of the

trailer. The stand shall be corrosion resistant. It shall include a 6-inch wheel that

allows horizontal positioning of the trailer. The stand shall be welded, not bolted,

to the tongue of the trailer.

(f)The trailer shall be provided with legal tail/brake lights, signals, and license plate

mounting bracket. The trailer shall be supplied with an electrical harness assembly

for connection to the tow vehicle and shall be terminated in a connector type to be

specified by the Engineer.

(g)The trailer shall be provided with a 2-inch “hammer blow coupler” style hitch in

accordance with SAE J684 and interchangeable with a 2½-inch Pintle coupler / ring

meeting SAE J847.

(h)The trailer spring leafs shall be rated at a minimum of 3500 pounds.
(i)The trailer shall be equipped with a sign display lift and control console. The lift

shall be electric, hydraulic lift, or combination of both with manual backup lift. The

lift shall be capable of lifting the display a minimum of seven feet (7’) above the

roadway surface. A mast safety pin shall be provided to prevent the sign display

from falling in the event of an electric or hydraulic system failure.

(j)The trailer shall have a minimum of 6,000-pound capacity hydraulic surge brake

system along with a breakaway latch.

460

Section 619 Section 619

(k)Illumination shall be provided as an integral part of the sign or trailer assembly to

change the sign controller data in darkness.

(l)The trailer shall contain batteries and photovoltaic (solar) panels as specified herein.

Photovoltaic (Solar) Panel System. Each PCMS shall include solar panels. A solar bank

shall be assembled using multiple solar panels. All photovoltaic panels shall be listed in

accordance with UL 1703, or equivalent. The solar cell bank shall have a minimum

capacity of 240 watts. The solar cell bank shall be mounted on a frame capable of being

tilted at a minimum of one direction up to 61 degrees with zero degrees being horizontal.

Solar cells shall be laminated between ethylene vinyl acetate and tempered glass. The solar

panel shall incorporate an extruded aluminum frame. The solar battery charge controller

shall include the following three state charger modes:

• Bulk

• Absorption

• Float

Battery Requirements. Each PCMS shall include batteries for primary energy storage on

trailers. The battery bank capacity shall be a minimum of 900 amp/hours at 12VDC at a

20-hour rate of discharge. The batteries shall be heavy duty deep cycle type rated for 80%

discharge. A battery power disconnect shall be provided.

Battery enclosures shall be vented to prevent the accumulation of explosive gases. The

battery cabinets must be lockable with a standard padlock.

AC Charging System. Each PCMS shall have an AC battery charging sub-system. The

system shall be UL listed and operate from a standard 120VAC generator meeting all NEC

requirements for portable equipment.

The solar battery charger shall include the following three state charger modes:

• Bulk

• Absorption

• Float

The AC battery charger shall have sufficient capacity to charge the battery bank from 80%

discharged to fully charged in 24-hours, and operate the sign simultaneously. The AC

battery charger shall be equipped with a male plug-in and a 50-foot long extension cord

constructed of a minimum 12-guage wire for this purpose.

.14.2--Controller to Sign Interface. Each PCMS shall meet all applicable

controller to sign interface requirements as outline in Section 4 of the NEMA TS-4

standard.

.14.3--Display Properties. Each PCMS shall have a cone of vision (viewing angle)

from the center (reference axis) shall be a minimum 15 degrees with the half-power

viewing angle defined such that at a given distance from the LED, luminous intensity

measured at any point at an angle of 7.5 degrees from the LED's center axis is no less than

half the luminous intensity measured directly on the LED's center axis.

461

Section 619 Section 619

The minimum word legibility requirements shall be 1232 feet or greater under daytime

light conditions and within the cone of visions as specified. Legibility is defined as the

ability to discern the content of a display using a “word message.” The minimum word

legibility requirement shall be documented either by a Department approved independent

testing laboratory or by participation in the NTPEP test program.

The minimum visibility requirements shall be 3000 feet or greater under daytime light

conditions and within the cone of vision as specified. Visibility is defined as the ability to

recognize that a display exists. The minimum visibility requirement shall be documented

either by a MDOT approved independent testing laboratory or by participation in the

NTPEP test program.

The PCMS shall be capable of displaying standard fonts and font alphabets as specified in

Sections 5.6.1 and 5.6.2.3 of the NEMA TS-4 standard and adhere to NTCIP 1203. The

PCMS shall also support moving arrows.

Any NTPEP test results shall be for the PCMS model being used and shall be within the

last three completed test cycles.

.14.4--Optical Components. The pixels for the PCMS shall be manufactured using

Light Emitting Diodes (LED). Changes to displays shall be performed by turning the LEDs

in a pixel either on or off. The discrete LED shall be an untinted, non-diffused, solid-state

lamp that uses Aluminum Indium Gallium Phosphide (AlInGap) technology manufactured

by Avago Technologies (formerly Agilent Technologies), Toshiba Corporation, Nichia

Corporation, or functional equivalent. Horizontal and vertical spacing between modules

shall be such that the horizontal and vertical pitch between all pixels is equal. A failure of

one pixel shall not affect the operation of any other pixel.

All LEDs used to create a display in a single portable sign shall have a nominally rated

LED life of 100,000 hours of operation under field conditions. This shall include operating

temperatures between -29°F to +165°F. LED life shall be defined as the time it takes for

the LED light output to degrade to half of the LED's initial light output. The current

through an LED shall be limited to the manufacturer’s recommendation under any

conditions. Each LED character module shall be rated for use over the environmental range

specified herein, including heat absorption due to sunlight. The LEDs shall be protected

from the outside environmental conditions, including moisture, snow, ice, wind, dust, dirt,

and UV rays (UVA and UVB). All LEDs shall be mounted so that they present a uniform

and legible display.

Pixels shall be replaceable in modular groupings (modules). All modules within a sign

shall be the same size and interchangeable. The replacement of any module shall be

possible with no more than simple non-vendor-specific hand tools, such as screw drivers

or wrenches, without any physical modification to the module.

.14.5--PCMS Controller and Storage Cabinets. All PCMS controller and storage

cabinets shall be a minimum of NEMA 3R rated and be completely encased and lockable

with a standard padlock as specified herein. A separate lockable storage cabinet shall be

provided to house various accessories. The controller cabinet shall be manufactured to

withstand all types of adverse weather conditions and shall be designed and installed to

keep insects out. All components inside the controller cabinet shall be accessible without

disconnecting any unassociated wires or components. The controller cabinet shall be

462

Section 619 Section 619

illumination. The keyboard terminal and control panel shall be housed. Lighted keys and

terminal displays are acceptable.

All controls in the controller cabinet shall be labeled. The cabinet shall have a voltmeter

gauge to indicate the current battery charge status. It shall have an amp gauge to indicate

the current/charging status. It will be acceptable to have a display via digital readout on a

control console or panel.

.14.6--Electronics and Electrical. Each PCMS shall meet all applicable electronics

and electrical requirements as outlined in Section 8 of the NEMA TS-4 standard.

Sign Controller. The PCMS shall include a local sign controller with firmware. The local

control interface shall have a keyboard capable of allowing full programming and control

of the PCMS locally. It shall have a separate serial RS-232 or USB connection to allow a

laptop computer using the remote control software to communicate directly with the sign

controller.

Local and remote interfaces shall be password protected to safeguard against unauthorized

use.

It shall perform and report the following minimum sign diagnostics both through the local

interface and Remote Control Subsystem.

• LED brightness controls

• Sign status

• Communications status

• Battery voltage

• Photocell ambient light level.

It shall automatically report a low battery alarm to a remote user through the Remote

Control Subsystem. It shall have an alarm for the controller door open and over

temperature.

It shall store and display both textual and graphical symbols. It shall store a minimum of

20 pre-programmed messages and graphics. It shall display preprogrammed (by

manufacturer) MUTCD symbolic messages and standard arrows. It shall schedule

predetermined sequences of messages based on a programmed time and date. Each

sequence shall display up to four (4) programmed messages (text and/or graphics). It shall

display conventional one, two, or three-line messages for display with a choice of a

minimum of three font sizes. Character width shall be proportional to the letter type. The

one line message font size shall be capable of displaying messages in full size to utilize the

maximum area of display.

It shall allow for automatic and manual controls to adjust the brightness of the LEDs.

Automatic control shall be capable of varying the LED brightness by sensing the ambient

light level using photocells. Manual brightness control shall be password protected to

safeguard against unauthorized use.

It shall display a preprogrammed default message or no message at all, after a power

recovery from a power failure. The sign shall shut down its LED display if internal cabinet

temperatures reach a level that is determined unsafe by the manufacturer.

463

Section 619 Section 619

All communications and power cabling shall be either shielded or routed within conduit to

minimize potential EMI/RFI effects.

Remote Control Subsystem. The PCMS shall be supplied with all the hardware and

software necessary to control the PCMS from a remote central station.

It shall have a cellular phone and/or modem capable of communication using the

Department’s provided cellular service provider. The Contractor shall coordinate with the

Department for a cellular service provider. The Contractor shall be responsible for

establishing cellular service and providing activated phone number(s) as directed and

approved by the Department. The Contractor shall pay for cellular service for this project

until the Final Maintenance Release as documented by the State Construction Engineer at

which time it will be turned over to the Department.

The cellular service type shall be CDMA/1xRTT or GSM/GPRS, as directed by the

Department.

It shall be capable of supporting connection and remote control, programming and

diagnostics via the Internet.

The subsystem shall have all necessary hardware such as external antenna,

communications cables, and controller interface and NTCIP Sign controller software. The

central station software must meet the following minimum requirements:

1) Windows XP compatible

2) Capable of running on any desktop or laptop.

3) Capable of controlling all PCMS functions through windows and GUIs (Graphical

User Interface)

4) NTCIP compatible as specified herein.

Communications. In addition to any protocols that may be available from the PCMS

Manufacturer, each sign controller shall support NTCIP as follows:

• NTCIP Protocol and Command Sets. This specification references several standards

through their NTCIP designated names and numbers. Each NTCIP Component

covered by these specifications shall implement the most recent version of the

standard that is available as of project advertisement date, including any and all

prepared amendments to the standards as of the same date.

Profile Implementation Conformance Specifications (PICS) for each NTCIP

standard required shall be submitted for review and approval to the Department.

• RS-232 Interface. Communication interfaces using RS-232 shall conform with the

following minimum requirements:

1101 – NTCIP Simple Transportation Management Framework (STMF)

1203 - NTCIP Object Definition for Portable Dynamic Message Signs

2301 - NTCIP AP-STMF

2201 - NTCIP TP-Transportation Transport Profile

2103 – NTCIP SPPPP/RS232

2104 - NTCIP SP-PMPP/RS232

464

Section 619 Section 619

• Subnet Level. For each communication interface, the NTCIP Components may

support additional Subnet Profiles at the manufacturer’s option. At any time, only

one Subnet Profile shall be active on a given communication interface. The NTCIP

Component shall be configurable to allow the field technician to activate the desired

Subnet Profile.

• Transport Level. For each communication interface, the communication interface

may support additional Transport Profiles at the manufacturer's option. Response

data-grams shall use the same Transport Profile used in the request. Each

communication interface shall support the receipt of data-grams conforming to any

of the identified Transport Profiles at any time.

• Application Level. For each communication interface, all interfaces shall comply

with NTCIP 1101 and shall meet the requirements for Conformance Level 1 (NOTE

-See Amendment to standard). Optionally, the NTCIP Component may support

SNMP traps. A communication interface may support additional Application

Profiles at the manufacturer's option. Responses shall use the same Application

Profile used by the request. Each communication interface shall support the receipt

of Application data packets at any time allowed by the subject standards.

• Information Level. For all communication interfaces, the information level protocol

shall provide Full, Standardized Object Range Support of all objects required by

these specifications unless otherwise indicated below. The maximum Response

Time for any object or group of objects shall be 200 milliseconds. All

communication interfaces shall implement all mandatory objects of all mandatory

Conformance Groups as defined in NTCIP 1203 and its respective amendments.

Table 1 indicates the modified object requirements for these mandatory objects.

Table 2 shows the required minimum support of messages that are to be stored in

permanent memory. The sign shall blank if a command to display a message

contains an invalid Message CRC value for the desired message. Table 3 specifies

the support of the required MULTI tags and itsranges.

The protocol shall also implement all mandatory objects of the following optional

conformance groups of NTCIP 1201.

o Time Management Conformal Group

o Report Conformal Group. Table 4 indicates the modified object

requirements.

o Implement all objects of the Font Configuration Conformance Group, as

defined in NTCIP 1203. Table 5 indicates the modified object requirements

for this conformance group.

o Implement all objects of the PCMS Configuration Conformance Group, as

defined in NTCIP 1203.

o Implement all objects of the Multi Configuration Conformance Group, as

defined in NTCIP 1203. Table 6 indicates the modified object requirements

for this conformance group.

o Implement all objects of the Multi Error Configuration, as defined in NTCIP

1203.

o Implement all objects of the Illumination/Brightness.

o Sign Status, as defined in NTCIP 1203.

465

Section 619 Section 619

o Status Error, as defined in NTCIP 1203.

o Pixel Error Status, as defined in NTCIP 1203.

o The sign display shall be capable of displaying preprogrammed MUTCD)

symbolic messages and standard arrows. Since the display of graphics is

currently not defined within the NTCIP Standards or its amendments, the

vendor shall propose and provide detailed documentation (i.e., interface

protocol description level) concerning the display of the specified graphical

shapes.

o Implement the optional objects listed in Table 7.

Table 1

Modified Object Ranges for Mandatory Objects

Object Reference Project Requirement

ModuleTableEntry NTCIP 1201

Clause 2.2.3

Shall contain at least one row

with moduleType equal to 3

(software). The moduleMake

shall specify the name of the

manufacturer, the

moduleModel shall specify

the manufacturer's name of

the component and the

modelVersion shall indicate

the model version number of

the component.

MaxGroupAddresses NTCIP 1201

Clause 2.7.1

Shall be at least 1

CommunityNamesMax NTCIP 1201

Clause 2.8.2

Shall be at least 3

PCMSNumPermanentMsg NTCIP 1203

Clause 2.6.1.1.1.1

Shall be at least 20*

PCMSMaxChangeableMsg NTCIP 1203

Clause 2.6.1.1.1.3

Shall be at least 50. Each

message shall support at least

4 pages per message.

PCMSFreeChangeableMemory NTCIP 1203

Clause 2.6.1.1.1.4

Shall be at least 70 when no

messages are stored.

PCMSMessageMultiString NTCIP 1203

Clause

2.6.1.1.1.8.3

The PCMS shall support any

valid MULTI string

containing any subset of those

MULTI tags listed in Table 4.

PCMSControlMode NTCIP 1203

Clause 2.7.1.1.1.1

Shall support at least the

following modes:

 local

 external

 central

 centralOverride

466

Section 619 Section 619

Table 2

Content of Permanent Messages

Perm. Msg. Num. Section 12 Description

1 Permanent Message #1 shall blank the display (i.e., command

the sign to use PCMSMessageType 7). It shall have a run-time

priority of 50.

Table 3

Required MULTI Tags

Code Feature

f1 Field 1 - time (12hr)

f2 Field 2 - time (24hr)

f8 Field 8 - day of month

f9 Field 9 – month

f10 Field 10 - 2 digit year

f11 Field 11 - 4 digit year

Fl (and /fl) flashing text on a line by line basis with flash rates controllable in 0.5

second increments.

Fo Font

J12 justification - line – left

J13 justification - line – center

J14 justification - line – right

J15 justification - line – full

Jp2 justification - page – top

Jp3 justification - page - middle

Jp4 justification - page - bottom

Nl New line

Np New page, up to 2 instances in a message (i.e., up to 4 pages/frames

in a message counting first page)

Pt page times controllable in 0.5 second increments.

Table 4

Modified Object Ranges for the Report Conformance Group

Object Reference Project Requirement

maxEventLogConfigs NTCIP 1201 Clause 2.5.1 Shall be at least 50

eventConfigurationMode NTCIP 1201 Clause

2.4.3.1

The NTCIP Component

shall support the following

Event Configuration Modes:

 onChange

 greaterThanValue

 smallerThanValue

maxEventLogSize NTCIP 1201 Clause 2.5.3 Shall be at least 200

maxEventClasses NTCIP 1201 Clause 2.5.5 Shall be at least 16

467

Section 619 Section 619

Table 5

Modified Object Ranges for the Font Configuration Conformance Group

Object Reference Project Requirement

numfont NTCIP 1203 Clause

2.4.1.1.1.1

Shall be at least 3*

maxFontCharacters NTCIP 1203 Clause

2.4.1.1.1.3

Shall be at least 127**

* Upon delivery, the first font shall be a standard 18-inch font. The second font shall

be a double-stroke 18-inch font. The third font shall be a 28-inch font.

** Upon delivery, the first three font sets shall be configured in accordance with the

ASCII character set for the following characters:

"A" thru "Z" - All upper case letters.

"a" thru "z" - All lower case letters.

"0" thru "9" - All decimal digits.

Space (i.e., ASCII code 0x20).

Punctuation marks shown in brackets [. , ! ? - ‘ ’ “ ” / ( )]

Special characters shown in brackets [# & * + < >]

Table 6

Modified Object Ranges for the MULTI Configuration Conformance Group

Object Reference Project Requirement

defaultBackgroundColor NTCIP 1203 Clause

2.5.1.1.1.1

The PCMS shall support

the following background

colors:

 black

defaultForegroundColor NTCIP 1203 Clause

2.5.1.1.1.2

The PCMS shall support

the following foreground

colors:

 amber

 orange

defaultJustificationLine NTCIP 1203 Clause

2.5.1.1.1.6

The PCMS shall support

the following line

justification:

 Left

 Center

 Right

 Full

defaultJustificationPage NTCIP 1203 Clause

2.5.1.1.1.7

The PCMS shall support

the following forms of

page justification:

 Top

 Middle

 Bottom

468

Section 619 Section 619

defaultPageOnTime NTCIP 1203 Clause

2.5.1.1.1.8

The PCMS shall support

the full range of these

objects with step sizes no

larger than 0.5 seconds

defaultPageOffTime NTCIP 1203 Clause

2.5.1.1.1.9

The PCMS shall support

the full range of these

objects with step sizes no

larger than 0.5 seconds

defaultCharacterSet NTCIP 1203 Clause

2.5.1.1.1.10

The PCMS shall support

the following character

sets:

 eightBit

Table 7

Optional Object Requirements

Object Reference Project Requirement

globalSetIDParameter NTCIP 1201

Clause 2.2.1

eventConfigLogOID NTCIP 1201

Clause 2.5.2.7

eventConfigAction NTCIP 1201

Clause 2.5.2.8

eventClassDescription NTCIP 1201

Clause 2.5.6.4

defaultFlashOn NTCIP 1203

Clause

2.5.1.1.1.3

The PCMS shall support the

full range of these objects

with step sizes no larger

than 0.5 seconds

defaultFlashOff NTCIP 1203

Clause

2.5.1.1.1.4

The PCMS shall support the

full range of these objects

with step sizes no larger

than 0.5 seconds

PCMSSWReset NTCIP 1203

Clause

2.7.1.1.1.2

PCMSMessageTimeRemaining NTCIP 1203

Clause

2.7.1.1.1.4

PCMSShortPowerRecoveryMessage NTCIP 1203

Clause

2.7.1.1.1.8

PCMSLongPowerRecoveryMessage NTCIP 1203

Clause

2.7.1.1.1.9

PCMSShortPowerLossTime NTCIP 1203

Clause

2.7.1.1.1.10

469

Section 619 Section 619

PCMSResetMessage NTCIP 1203

Clause

2.7.1.1.1.11

PCMSCommunicationsLossMessage NTCIP 1203

Clause

2.7.1.1.1.12

PCMSTimeCommLoss NTCIP 1203

Clause

2.7.1.1.1.13

PCMSEndDurationMessage NTCIP 1203

Clause

2.7.1.1.1.15

PCMSMemoryMgmt NTCIP 1203

Clause

2.7.1.1.1.16

The PCMS shall support

the following Memory

management Modes:

 normal

 clearChangeableMessage

 clearVolatileMessages

PCMSMultiOtherErrorDescription NTCIP 1203

Clause

2.7.1.1.1.20

If the vendor implements

any vendor-specific MULTI

tags, the PCMS shall be

provided with

documentation that includes

meaningful error messages

within this object whenever

one of these tags generates

an error.

PCMSIllumLightOutputStatus NTCIP 1203

Clause

2.8.1.1.1.9

watchdogFailureCount NTCIP 1203

Clause

2.11.1.1.1.5

PCMSStatDoorOpen NTCIP 1203

Clause

2.11.1.1.1.6

fanFailure NTCIP 1203

Clause

2.11.2.1.1.8

fanTestActivation NTCIP 1203

Clause

2.11.2.1.1.9

tempMinCtrlCabinet NTCIP 1203

Clause

2.11.4.1.1.1

tempMaxCtrlCabinet NTCIP 1203

Clause

2.11.4.1.1.2

470

Section 619 Section 619

tempMinSignHousing NTCIP 1203

Clause

2.11.4.1.1.5

tempMaxSignHousing NTCIP 1203

Clause

2.11.4.1.1.6

NTCIP Compliance Documentation. Software shall be supplied with full documentation,

including a CD-ROM containing ASCII versions of the following Management

Information Base (MIB) files in Abstract Syntax Notation 1 (ASN.1) format.

(a)The relevant version of each official standard MIB Module referenced by the device

functionality shall be included. If the device does not support the full range of any

given object within a Standard MIB Module, a manufacturer specific version of the

official Standard MIB Module with the supported range indicated in ASN.1 format

in the SYNTAX and/or DESCRIPTION fields of the associated OBJECT TYPE

macro shall be provided. The filename of this file shall be identical to the standard

MIB Module, except that it will have the extension ".man".

(b)A MIB Module in ASN.l format containing any and all manufacturer-specific objects

supported by the device with accurate and meaningful DESCRIPTION fields and

supported ranges indicated in the SYNTAX field of the OBJECT-TYPE macros shall

be provided. This includes a MIB containing any other objects supported by the

device.

(c)Additionally, the manufacturer shall provide a test procedure that demonstrates how

the NTCIP compliance of both, the data dictionaries (NTCIP 1201, 1203, and their

amendments) and the communications protocols have been tested. The manufacturer

shall allow the use of any and all of this documentation by any party authorized by

the Department for systems integration purposes at any time initially or in the future,

regardless of what parties are involved in the systems integration effort.

.14.7--Operational Security. The Contractor shall change the manufacturer’s

default passwords for all levels of access. The passwords for each level of access shall be

different. The individual passwords shall be at least eight (8) characters in length, contain

both upper and lowercase alphabetic characters (A-Z, a-z), have at least one (1) numerical

character (0-9), and have at least one (1) special character (~!@#$%^&*()_-+=). The

passwords shall not 1) spell a word or series of words that can be found in a standard

dictionary, 2) spell a word with a number added to the beginning and the end, or 3) be

based on any personal information such as user id, family name, pet, birthday, etc. The

Contractor shall provide the Project Engineer will a listing of all passwords for each PCMS

prior to the PCMS being placed on the project. If multiple PCMS are used on a project,

they shall each have distinct passwords.

.14.8--Additional Equipment Requirements. When the contract requires the

PCMS to include a speed radar unit, the radar shall operate in the "K" band, in an "approach

only" mode. In conjunction with the radar, the sign shall be capable of displaying the

vehicle speeds. The unit shall be programmable to allow the interruption of user-defined

messages by the vehicle speed display and/or alternate messages whenever a settable speed

threshold is exceeded. The radar unit shall be encased in an aluminum enclosure with a

polycarbonate lens, and the metal portion shall receive the same protective coating,

priming, and painting as the rest of the sign.

471

Section 619 Section 619

.14.9--System Documentation. For each PCMS, the Contractor shall provide two

(2)user manuals. The user manual shall include description and samples for all operational

functions, software required to operate the sign on site and remotely, all wiring diagrams,

a parts lists, the sign specifications, warranty information, maintenance information and

schedule, and a trouble shooting table.

Each copy shall be bound and shall contain laminated sheets.

.15--Glare Paddles. Glare paddles shall be those listed on the Department's APL"

619.03Construction Requirements

.1--General. Traffic control devices shall be furnished and utilized in accordance

with the Traffic Control Plan (TCP) as referenced in Section 618. Upon failure of the

Contractor to adequately maintain traffic control devices and safe movement of traffic

through the construction zones, the provisions of Subsection 105.15 will be invoked.

.2--Temporary Stripe. Temporary stripes are pavement markings, temporary in

nature, that are used to direct traffic from its customary path, to be removed from the

pavement course under use for further temporary traffic control, to be covered by the next

pavement course and/or to be replaced by permanent stripes. Temporary stripes shall be

4-inch paint or preformed tape as designated on the plans or when not designated, the use

of paint or tape will be at the Contractor's option. Temporary stripes on surface treatments

shall be paint.

All temporary stripe shall be placed in accordance with the plans and the requirements set

out in Section 625, except that alignment of temporary stripe placed on underlying courses

shall have a tolerance of four inches in fifty (50) feet from true alignment for skip stripes

and edge lines and one inch in fifty (50) feet from true alignment for no-passing stripes and

lane lines. When preformed tape is used on the final pavement course for temporary traffic

markings, it shall be removed at no additional cost to the State.

Temporary paint stripe requiring removal shall be removed by carefully controlled blast

cleaning, approved grinding or other approved methods in such a manner that the surface

to which the stripe is applied will not be unnecessarily marred or damaged. Preformed tape

is to be removed in accordance with the manufacturer's recommendations.

Temporary paint stripe placed on the final pavement course may be left in place and

covered with permanent stripe of the same color provided the temporary stripe has been

satisfactorily placed in the proper location. Under this condition, any remaining temporary

paint stripe not covered by the permanent stripe shall be removed at no additional cost to

the State.

Painted traffic stripe removed from the final asphalt pavement surface shall be sealed with

an approved sealant. The Engineer may wave the sealant requirement when the area to be

sealed is insignificant. This sealing operation shall be performed at no additional costs to

the State.

All temporary pavement markings placed and measured for payment under this section

472

Section 619 Section 619

shall include any required removal. Removal of all temporary stripe will not be measured

for separate payment.

Existing pavement markings conflicting with temporary markings shall be removed.

Removal of such materials (paint, tape, marker, etc.) will be measured and payment made

under Section 202. When measuring removal of pavement markings for payment, the skips

will not be included in the measurement.

.3--Portable Traffic Signals

.3.1--Installation. The Contractor shall be responsible for placing the portable

traffic signal(s) in the appropriate location based as shown in the plans and meeting the

MUTCD and ITE standards for visibility to motorists and for safe operation.

The Contractor shall be responsible for providing all hardware, software, communications

equipment and licenses to operate a complete system. All equipment shall be installed

according to the manufacturer's recommendations.

The Contractor shall be responsible for transport, setup, configuration, operation and

monitoring of the portable traffic signals throughout the entire project. The Engineer shall

approve all timing and settings that are used for operation of the signal.

It may be necessary to relocate the portable traffic signals during the project. The cost of

the relocation shall be included in the lump sum price bid.

.3.2--Conformance / Testing. Each portable traffic signal shall undergo testing to

verify conformance with this specification. The Contractor shall conduct a Project Testing

Program as required below. All costs associated with the Project Testing Program shall be

included in overall contract prices; no separate payment will be made for any testing.

.3.2.1--General Requirements. This work shall meet the following general

requirements.

1) The Contractor is responsible for planning, coordinating, conducting and

documenting all aspects of the Project Testing Program. The Project Engineer

and/or their designee(s) are only responsible for attending and observing each test,

and reviewing and approving the Contractor's test results documentation. The

Project Engineer and/or their designee(s) reserve the right to attend and observe all

tests.

2) Each test shall fully demonstrate that the equipment being tested is clearly and

definitely in full compliance with all project requirements.

3) Test procedures shall be submitted and approved for each test as part of the project

submittals. Test procedures shall include every action necessary to fully

demonstrate that the equipment being tested is clearly and definitively in full

compliance with all project requirements. Test procedures shall cross-reference to

these specifications or the project plans. Test procedures shall contain

documentation regarding the equipment configurations and programming.

4) No testing shall be scheduled until approval of all project submittals and approval

of the test procedures for the given test.

5) The Contractor shall provide all ancillary equipment and materials as required in the

approved test procedures.

473

Section 619 Section 619

6) The Contractor shall request in writing the Project Engineer’s approval for each test

occurrence a minimum of 14 days prior to the requested test date. Test requests

shall include the test to be performed and the equipment to be tested. The Project

Engineer reserves the right to reschedule test request if needed.

7) All tests shall be documented in writing by the Contractor in accordance with the

test procedure and submitted to the Project Engineer within seven (7) days of the

test. Any given test session shall be considered incomplete until the Project

Engineer has approved the documentation for that test session.

8) All tests deemed by the Project Engineer to be unsatisfactorily completed shall be

repeated by the Contractor. In the written request for each test occurrence that is a

repeat of a previous test, the Contractor shall summarize the diagnosis and

correction of each aspect of the previous test. The test procedures for a repeated test

occurrence shall meet all the requirements of the original test procedures, including

review and approval by the Project Engineer.

9) The satisfactory completion of any test shall not relieve the Contractor of

responsibility to provide a completely acceptable and operating system that meets

all requirements of this project.

.3.2.2--Portable Traffic Signal Pre-Installation Test (PIT). The Contractor shall

perform PIT on the portable traffic signals units as they arrive from the factory. The goal

of the PIT is to verify that the portable traffic signals were not damaged during shipping

and that all components are working.

.3.2.3--Portable Traffic Signal Stand Alone Test (SAT). The Contractor's

comprehensive SATs for the portable traffic signals shall be completed once the signal has

been location on the site where it will be utilized. The SAT shall be sufficient to

demonstrate compliance with all requirements specified herein.

.3.3--System Maintenance and Support. The portable traffic signal(s) shall be

maintained and supported by the Contractor throughout the duration of the project. The

Contractor shall provide MDOT with a 24/7 contact to respond to any issues and shall be

required to respond within two (2) hours to any call from the Engineer or designated

representative concerning any request for correcting any deficiency in the signal system.

Equipment damaged or otherwise not functioning shall be repaired or replaced immediately

upon notification by MDOT. Sufficient spare parts to repair common components of the

portable traffic signal such as heads, controller, load switch, relays, etc. shall be available

on site. All equipment installation, service, repair, relocation and removal are the

responsibility of the Contractor.

.3.4--System Documentation. For each type signal, the Contractor shall provide

the Engineer with a user manual. The user manual shall include description and samples

for all operational functions, software required to operate the signal on site and remotely

(if applicable), all wiring diagrams, a parts lists, the signal specifications, maintenance

information and schedule, and a trouble-shooting guide.

.4--Reflective Pavement Markers. Reflective pavement markers for construction

zones shall be secured to the pavement by an approved adhesive. The portion of the

highway surface to which the marker is to be bonded shall be free of dirt, grease, oil,

moisture, loose or unsound layers and any other material that would adversely affect the

bond of the adhesive. Clean pavement need not be blast-cleaned unless the surface contains

an abnormal amount of asphalt or the surface is contaminated with dirt, grease, oil, or any

474

Section 619 Section 619

other material that would adversely affect the bond of the adhesive. Necessary cleaning

shall be performed by blast cleaning.

When a pressure-sensitive pad is used, a primer shall be applied directly to the road surface

with a brush or sprayer but is not to be applied when the ambient temperature is lower than

50°F. No marker shall be installed when the relative humidity of the air is greater than 80

percent or when the pavement is not surface dry. Traffic shall not be permitted to run over

the primed area until after the markers have been installed. After priming, allow one

minute for the primer to dry, then peel the release paper from the pressure-sensitive pad

and immediately place the marker in the correct position on the primed road surface and

apply light pressure. Drive slowly over the located marker with one wheel of a truck to

help set it in place. Traffic may be allowed immediately.

All markers shall be installed in a uniform line, with controls established by the Engineer.

The Engineer will establish controls for each line of markers by setting control points at

not less than approximately 600-foot intervals on tangents and 50-foot intervals in curves.

All additional work necessary to establish intermediate control points and individual

marker points shall be performed by the Contractor. On curves, the line of markers on lane

lines and edge lines shall follow the normal curvature of the curve and placement on chords

or other variations from the normal curvature will not be permitted, unless specifically

shown on the plans or ordered by the Engineer.

Reflective markers shall be installed in such a manner that the reflective face of the marker

is perpendicular to a line parallel to the roadway centerline. No markers shall be installed

over longitudinal or transverse joints of the pavement surface.

All markers placed out of alignment shall be removed and replaced by a new marker.

.5--Impact Attenuators. Impact attenuators shall be installed and maintained by

experienced workmen familiar with the installation of impact attenuators. Installation shall

be in accordance with the recommendations of the manufacturer. Each impact attenuator

shall also include one replacement package. A replacement package shall consist of the

quantity of materials necessary to repair one hit for every three attenuators in place. The

Contractor shall use these parts to maintain the attenuator during the construction period.

When it becomes necessary to install a replacement package, the Contractor shall order an

additional replacement package to have available for future use. All unused parts and the

attenuators shall become the property of the Contractor upon completion of the project.

.6--Temporary Guardrail. Temporary guardrail shall be installed in accordance

with the plans and the applicable provisions of Section 606.

The sites where temporary guardrail has been removed shall be restored to their original

condition or as provided in the contract documents.

Salvage of temporary guardrail designated to become the property of the Department shall

be in accordance with Subsection 202.03.

.7--Maintenance of Traffic Signs. All signs, whether placed new or previously

used, shall meet the requirements of this specification on each inspection. Signs failing to

comply with these requirements shall be replaced at no additional cost to the State.

475

Section 619 Section 619

.8--Snap-Back Delineators. Snap-back delineators shall be installed in accordance

with the manufacturer's recommendations and at the locations shown on the plans or

directed by the Engineer. Delineators that are damaged by traffic to the extent that they

are non-functional shall be replaced as quickly as possible.

.9--Portable Median Barrier. Portable median barriers shall be installed in

accordance with the manufacturer’s recommendations. The barriers shall be installed at

the locations shown on the plans, or as directed by the Engineer.

.10--Changeable Message Sign. Each changeable message sign shall be installed

and continuously operated at the location selected by the Engineer on State right-of-way.

The Contractor is advised that selected locations may be outside the planned limits of the

project. The Contractor shall perform all work necessary for preparation of the site selected

and approved by the Engineer, to ensure maximum safety and sign visibility for the

traveling public and may be required to remove any temporary work at a later date as

directed by the Engineer. The Contractor will also place a minimum of two plastic drums

in advance of the sign and one beside the sign as long as it is in use. The Contractor shall

be required to move the sign to a new location if directed by the Engineer.

The Contractor may be permitted to bring electric power from outside the normal right-of-

way for operation of the equipment if the Department determines that the installation

operation will not be hazardous to the traveling public. The Contractor will be required to

secure a permit from the Department prior to any work by the power company on the right-

of-way. The entire cost of providing electrical service, power to operate the equipment,

and removal of the power source from the right-of-way shall be borne by the Contractor.

The changeable message sign(s) will remain the property of the Contractor after the

Engineer determines that there is no further need for the sign(s) on the project.

.11--Glare Paddles. Glare paddle installation shall consist of furnishing, installing,

maintaining, removing and relocating glare paddles as required. Glare paddles shall be

placed atop precast median barriers, or other devices, at locations shown in the plans, or as

directed by the Engineer.

The paddles shall be six to nine inches (6" to 9") in width, 24 to 36 inches in height, and

spaced a maximum of 24 inches apart. The paddles shall be attached to the top of the

devices in accordance with manufacturer’s recommendations at a 22 degree angle. A

yellow high-intensity reflective strip shall be attached vertically to each side of one of the

paddles such that the spacing is 10 feet apart. Unless otherwise directed, these strips shall

be placed on the edge of the paddle adjacent to traffic. These reflective strips shall be made

of 2-inch by 12-inch material conforming to the requirements of Subsection 721.06 of the

Standard Specifications.

All glare paddles shall be properly maintained. Maintenance will include replacement of

damaged or missing blades, improper reflectorization, and any other portions of the

installation that may fail, for the entire length of time that the paddles are in place. Cleaning

of the reflective material shall be accomplished by any means that does not damage the

paddles and in a manner that is not hazardous to traffic. Cleaning shall be accomplished

on an as-needed basis or as ordered by the Engineer.

476

Section 619 Section 619

The Contractor shall relocate the glare paddles as required during construction at no

additional cost to the State.

After completion of the work, glare paddles and attachments shall remain the property of

the Contractor.

619.04Method of Measurement. Traffic control devices will be measured one time only

by the units indicated. When moved from the original location to other locations, as

required by the contract or as directed by the Engineer, traffic control devices will not be

measured for additional payment except when the contract includes the pay item, "Remove

and Reset". The total pay quantity for each traffic control device excluding traffic stripe

shall not exceed the maximum number of installations in place at any given time during

the life of the contract. Unless otherwise provided, replacement of devices will not be

measured for payment.

Temporary stripe, completed and removed in accordance with the requirements of this

Section, will be measured by the mile or by the linear foot, as indicated, from end-to-end

of individual stripes. In the case of skip lines, the measurement will include skips. The

length used to measure centerline, lane lines and edge stripes will be the horizontal length

computed along the stationed control line. Detail traffic stripe will be measured by the

linear foot from end-to-end of individual stripes. Measurement will be made along the

surface of each stripe and will exclude nominal skip intervals where specified. Stripes

more than four inches in width will be converted to equivalent lengths of four-inch stripe.

Legend, which is to include railroad markings, pedestrian crosswalks and stop lines, will

be measured by the square foot or linear foot. Pay areas of individual letters and symbols

will usually be shown on the plans and measured by the square foot. Transverse railroad

bands, pedestrian crosswalks and stop lines will generally be measured by the linear foot,

and stripes more than four inches in width will be converted to equivalent lengths of four-

inch widths.

Each impact attenuator installation, including one replacement package, will be measured

per each installation as shown on the plans. Replacement packages, excluding the package

included with the initial attenuator, will be measured per each in accordance with these

specifications.

Initial snap-back delineators will be measured per each. Replacement will be measured as

follows:

(a)Replace reflective material measured as 1/4 unit.
(b)Replace complete tube measured as 1/3 unit.
(c)Replace shock cord adapter measured as 1/3 unit.

Changeable message signs, as described above, will be measured per each. When directed,

separate measurements will be made for items included in the contract and required for

temporary site preparation for the sign as referenced in Subsection 619.03.10. Materials

for which no pay items are included in the contract will not be measured for separate

payment. Separate measurements will not be made for moving the changeable message

sign to a new location, but materials used for which pay items are included in the contract

and are necessary for repositioning the sign as directed by the Engineer will be measured

477

Section 619 Section 619

for separate payment. Removal of materials used for site preparation for changeable

message signs will not be measured for separate payment.

Portable traffic signals of the type specified will be measured per each.

The lengths of median barrier, including remove and reset median barrier, will be measured

per linear foot by multiplying the number of commercial lengths installed by the nominal

length of the barrier.

619.05Basis of Payment. Traffic control devices will be paid for at the contract unit

price for the units specified. Devices that have been measured for payment and

subsequently require repair or replacement will be dropped from payment on future

estimates unless satisfactorily repaired or replaced.

Payment for devices for which no pay items are contained in the contract will be included

in the unit prices of contract items and/or in the lump sum contract price for Maintenance

of Traffic.

Payment for items required by the Engineer for temporary location of the changeable

message sign, and for which pay items are included in the contract, will be made by the

individual pay item. No additional payment will be made for working outside the planned

indicated project limits.

Payment for removal of materials used for site preparation at changeable message sign

locations shall be included in the contract price for Maintenance of Traffic.

Portable traffic signals of the type specified will be paid for at the contract unit price per

each, which price shall be full compensation for furnishing, installing, testing, operating,

relocating a complete portable traffic signal as required, integration, configuration, and all

other materials, equipment, labor, tools and incidentals necessary to complete the work.

The prices thus paid shall be full compensation for completing the work.

Payment will be made under:

619-A1: Temporary Traffic Stripe, Continuous White,

Description * - per linear foot or mile

619-A2: Temporary Traffic Stripe, Continuous Yellow,

Description * - per linear foot or mile

619-A3: Temporary Traffic Stripe, Skip White,

Description* - per linear foot or mile

619-A4: Temporary Traffic Stripe, Skip Yellow,

Description* - per linear foot or mile

619-A5: Temporary Traffic Stripe, Detail, Description* - per linear foot

619-A6: Temporary Traffic Stripe, Legend, Description* - per square foot

or linear foot

478

Section 619 Section 619

619-B: Blank

619-C1: Red-Clear Reflective Raised Pavement Marker - per each

619-C2: Two-Way Yellow Reflective Raised Pavement Marker - per each

619-C3: One-Way Clear Reflective Raised Pavement Marker - per each

619-C4: One-Way Yellow Reflective Raised Pavement Marker - per each

619-C5: Yellow Clear Reflective Raised Pavement Marker - per each

619-C6: Red-Clear Reflective High Performance Raised Marker - per each

619-C7: Two-Way Yellow Reflective High Performance Raised

Marker - per each

619-C8: One-Way Clear Reflective High Performance Raised

Marker - per each

619-C9: One-Way Yellow Reflective High Performance Raised

Marker - per each

619-C10: Yellow Clear Reflective High Performance Raised Marker - per each

619-D1: Standard Roadside Construction Signs, Less than

10 Square Feet - per square foot

619-D2: Standard Roadside Construction Signs,

10 Square Feet or More - per square foot

619-D3: Remove and Reset Signs, All Sizes - per each

619-D4: Directional Signs - per square foot

619-D5: Directional Signs, Overhead, Location - lump sum

619-E1: Flashing Arrow Panel, Type____ - per each

619-E2: Sequencing Chevron Panel, Size - per each

619-E3: Changeable Message Sign ***** - per each

619-F1: ** Median Barrier, *** - per linear foot

619-F2: Remove and Reset ** Median Barrier, *** - per linear foot

619-F3: Delineators, Mounting, Description - per each

619-F4: Snap-Back Delineator - per each

479

Section 619 Section 619

619-F5: Snap-Back Delineator, Replacement - per each

619-G1: Blank

619-G2: Barricades, Type I - per each

619-G3: Barricades, Type II - per each

619-G4: Barricades, Type III, **** - per linear foot

619-G5: Free Standing Plastic Drums - per each

619-G6: Warning Lights, Type A - per each

619-G7: Warning Lights, Type B - per each

619-G8: Warning Lights, Type C - per each

619-H1: Traffic Signal, Location - lump sum

619-H2: Traffic Signal, Portable, Type ___ - per each

619-H3: Hazard Identification Beacons - lump sum

619-J1: Impact Attenuator, Speed Rating - per each

619-J2: Impact Attenuator, Speed Rating, Replacement Package - per each

619-J3: Remove and Reset Impact Attenuator ***** - per each

619-K1: Installation and Removal of Guardrail, Type____,

Class____ - per linear foot

619-K2: Installation and Removal of Guardrail, Type____

Bridge End Section - per each

619-K3: Installation and Removal of Guardrail, Type____

Cable Anchorage - per each

619-K4: Installation and Removal of Guardrail, Terminal

End Section - per each

619-L: Glare Paddles - per linear foot

* The description for temporary traffic stripe will be shown as "paint" or "tape.”

In the case of "tape" the type will also be designated. When the description is

not designated, the use of "paint" or "tape" will be at the Contractor's option.

** Indicate Concrete or Portable

*** Indicate Speed Rating, Color, etc. if applicable

**** Indicate if barricade is to remain with “Permanent”

***** Indicate when options are required 480