1204. 2(k) 1204. 3(a)
• An 18-gauge stainless steel lashing
• Slack loop rack and attachment hardware
• Slack loop cable clamps
• Nylon strap for slack loop cable entry/exit
1204.3CONSTRUCTION —As directed and as follows:
appropriate installation techniques so the optical and mechanical characteristics of the cable are not degraded. Unless otherwise approved, use only the equipment and procedures specified by the manufacturer of the fiber optic cable. Install the cable in such a way the manufacturer’s minimum bending radius and force limitations are not violated before, during, or after installation. Before any fiber optic cable installation is performed, provide the Representative with four copies of the cable manufacturer's recommended installation plan and equipment set up locations and maximum force limitations for each cable size and type. The installation system to be used is to be inspected and approved by the Representative. P rovide a list of the minimum allowable cable bending radius and cable manufacturer's approved pulling lubricants and guidelines for their application. Only these lubricants are allowed. Establish adequate voice communications between the blower units and receiving end and all intermediate locations. Set up the cable reels on the same side of the junction box as the conduit section in which the cable is to be placed. Make the reel level and bring it into proper alignment with the conduit sections o the cable will pass from the top of the reel in a long smooth bend into the duct without twisting. Do not pay off the cable from the bottom of the reel. Feed the cable by manually rotating th e wheel. Install the cable in the duct with a factory installed cable grip and swivel attached to the air carrier unit to prevent twisting during the installation. Use an approved cable feeder guide between the cable reel or storage stack and the face of the duct to protect the cable, and to guide the cable into the duct as it is payed off the reel or from the storage stack. The dimensions and set -up of the feeder g uide are to be such that the cable does not bend at any location to a radius less than the cable's minimum allowable bending radius. Do no t exceed this minimum -bending radius at any time during cable installation. Keep cable ends sealed at all times during installation, using an approved cable end cap. Do not use tape to seal the cable end. Keep the cable end sealed until termination takes place. Provide a minimum of 50 feet of slack for cables that are not immediately terminated. Ensure the blower tractor unit is not allowed to continue to operate if cable motion stops. As the cable reaches any intermediate locations, mak