Effective with the December 2018 Letting 312 2019 Standard Spec ifications Section 527 Structural Plate Pipe and Pipe Arches
527.1Description
527.2Materials
steel or aluminum alloy structural plates unless the contracts pecifies otherwise.
use aluminum bolts and nuts.
the radii of curvatures the contract designates.
527.3Construction
527.3.1 Fabrication 527.3.1.1 Description of Plates
manufacturer’s standard plate wi dth and length for the size structure specified, and stagger the joints either circumferentially or longi tudinally. Measure plate width circumferentially, or parallel to the highway centerline. Plates sha ll include an approximately 2-inc h lip beyond each end crest, resulting in the given structure’s actual length being approximately 4 inches longer than the nominal length, except if skewed or beveled. Connect the plates at longitudinal and circumferential seams by bolts.
527.3.1.2 Forming and Punching Plates
except end plates, are interchangeable during erection.
row in the valley and one in t he crest of the corrugations. Sta gger the bolt holes between crest and valley for steel plates.
structure approximately 10 inches.
the plates.
circles of the required diameters.
burned edges free from oxide and burrs. Place legible identification numerals on eac h plate part to designate its proper position in the finished structure. 527.3.2 Erection
backfill compaction.
supported at the spec ified grade to fit the lower plates of the structure. If rock, in either ledge or boulder form is encountered, remove it below grade and replace with foundation backfill conforming to 520.2 to provide compacted bedding of a thickness of not less than 1 /2 inch for every foot of fill above the structure, with a minimum a llowable thickness of 8 inches. If there is no stable foundation at the grade established, remove and r eplace unstable soil under the s tructure and for a width of at least one diameter on each side of the structure with foundation backfill , and compact to provide adequate support for the structure, unless the plans or special provisio ns specify other special construction methods.
arch.
Effective with the December 2018 Letting 313 2019 Standard Spec ifications (4) After placing all the plates, tighten all bolts to a torque va lue between 100 foot-pounds and 300 foot- pounds inclusive. Tighten all bolts before starting backfilling . 527.3.3 Backfilling Pipe and Pipe Arches
pipe arch in layers not greater than 6 inches until at least 3/ 4 of the depth is backfilled. Ensure thorough backfill comp action at the haunches of pipe arches and between the pipe or pipe arch and the sides of the trench, or for a distance each side of the pip e or pipe arch equal to the diameter of the pipe or pipe arch. Place the re maining 1/4 depth of fill to the top of structure equally on each side of the structure in layers not greater than 12 inches.
construction equipment over it. 527.3.4 Vertical Elongation
Pre-form the plates in the shop to provide the required elongation. 527.3.5 Defective Work
Elliptical shaping, unless specified. Uneven laps. Variation from a straight centerline. Ragged edges. Loose, unevenly lined, or spaced bolts. Illegible brand. Bruised, scaled, or broken spelte r coating. Dents or bends in t he metal.
527.4Measurement
installed by the linear foot acceptably completed, measured alo ng the invert.
527.5Payment
items: ITEM NUMBER DESCRIPTION UNIT
527.0100 - 0299 Pipe Structural Plate (size) LF
527.0300 - 0499 Pipe Arch Str uctural Plate (span) LF
providing the pipe or pipe ar ch including foundation backfill. The department will pay separately for cast-in-place concrete and alternate endwall installations unde r the Concrete Masonry Endwalls bid item as specified in 504.5 and other associated bid items.
210.5 .
Pipe or Pipe Arches bid item as specified in 206.5 .
contract contains the Water bid item, the department will pays eparately for water under 624.5 .
Effective with the December 2018 Letting 314 2019 Standard Spec ifications Section 530 Corrugated Plastic Pipe Culverts
530.1Description
530.2Materials
conforms to the plans and as follows: - For polyethylene conform to AASHTO M294 typeS. - For polypropylene confo rm to AASHTO M330 typeS.
cross or side drains conforming to 521.2 , or aluminum apron endwalls conforming to 525 as the contract specifies. Furnish conne ctor rods, connector bands, or other devices that fit the culvert pipe corrugations and provide a tigh t connection between the culvert and endwall.
530.3Construction
530.4Measurement
specified for pipe in 520.4 .
530.5Payment
items: ITEM NUMBER DESCRIPTION UNIT
530.0100 - 0299 Culvert Pipe Corrugated Polyethylene (size) LF
530.1100 - 1299 Culvert Pipe Corru gated Polypropylene (size) LF
- Pipe bid items. - Cast-in-place concrete and alte rnate endwall installations. - Water for compacti on and dust control. - Excavation and foundation ba ckfill at depths greater than 6 i nches below the culvert.
sloped steel apron endwalls under the appropriate 521 bid items; and for aluminum apron endwalls under the appropriate 525 bid items.