Drainage Pipe
Description
624.01This work consists of furnishing and installing pipe defined by class for culverts (cross
drains), side drains, and storm sewers per these specifications and in conformity with the lines and grades shown on the plans or established.
Materials
624.02Materials shall meet the requirements in the Contract and in the following subsections
Abbreviation Description Subsection CSP Corrugated Steel Pipe 707.02 Bit. Co. CSP Bituminous Coated Corrugated Steel Pipe 707.03 A.F. Bo. CSP Aramid Fiber Bonded Corrugated Steel Pipe 707.03 CAP Corrugated Aluminum Pipe 707.06 PCSP- both sides Precoated Corrugated Steel Pipe coated on both sides with 10 mils minimum707.10 ALT2 CSP Aluminized Corrugated Steel Pipe Type 2 707.11 RCP Reinforced Concrete Pipe, Type I, II, or V Cement 706.02 NRCP Nonreinforced Concrete Pipe, Type I, II, or V Cement 706.01 Plastic Polyvinyl Chloride (PVC), Polyethylene (PE), Steel Reinforced Polyethylene (SRPE), and Polypropylene (PP) 712.13
All precoated sheet steel for PCSP culvert shall be tested by the manufacturer for coating holidays and certified free of defects. The coating will be visually inspected by the Engineer during construction and all damage found shall be repaired in an approved manner.
Connecting bands shall receive the same corrosion protection as the pipe where they are used. Coatings conforming to the requirements of Sections 706 and 707 will be permitted as applicable. Connecting bands and pipe extensions shall be of similar metal, or of non-metallic material, to avoid galvanic corrosion.
End sections for concrete or metal pipe shall be the same material as the pipe and meet the requirements for the same class as that specified for the pipe per Table 624-1.
Plastic end sections shall not be used. When plastic pipe is to be installed with end sections, steel or concrete end sections meeting the same class as that specified for the pipe per Table 624-1 shall be used.
624.02 The Contractor may furnish any pipe material allowed in Table 624-1 for the class of pipe specified in the Contract except for storm drains. The Contractor may furnish RCP, PVC, SRPE or PP allowed in Table 624-1 for the class of pipe specified in the Contract for storm drains. The Contractor shall state at the Pre-construction Conference the pipe materials intended to be furnished.
Table 624-1 Materials Allowed for Class of Pipe Material Allowed** Class of Pipe* 0 1 2 3 4 5 6 7 8 9 CSP Y N N N N N N N N N N ALT2 CSP Y Y Y Y Y N N N N N N Bit. Co. CSP Y Y^ N N N N N N N N N A.F. Bo. CSP Y Y Y Y Y Y Y N N N N CAP Y Y# Y# Y# Y# Y N N N N N PCSP - both sides Y Y Y Y Y Y Y N N N N PVC Y Y Y Y Y Y Y Y Y Y Y PE Y Y Y Y Y Y Y Y Y Y Y PP Y Y Y Y Y Y Y Y Y Y Y SRPE Y Y Y Y Y Y Y Y Y Y Y RCP (SP0), Y Y N N N N N Y N N N RCP (SP1) , Y Y Y N N N N Y Y N N RCP (SP2) , Y Y Y Y Y N N Y Y Y N RCP (SP3) , Y Y Y Y Y Y Y Y Y Y Y
Table 624-1 Notes: * As determined by the Department per the CDOT Pipe Selection Guide. Determination is based on abrasion and corrosion resistance. ** Y=Yes; N=No. ^Coated Steel Structural Plate Pipe of equal or greater diameter, conforming to Section 510, may be substituted for Bit. Co. CSP at no additional cost to the project. #Aluminum Alloy Structural Plate Pipe of equal or greater diameter, conforming to Section 510, may be substituted for CAP at no additional cost to the project. SP= Class of Sulfate Protection required per subsection 601.04 as revised for this project. RCP shall be manufactured using the cementitious material required to meet the SP class specified. For pipe classes 6 and 10, the RCP shall be coated per subsection 706.07 when the pH of either the soil or water is less than 5. The Contract will specify when RCP is to be coated. Concrete shall have a compressive strength of 4500 psi or greater. Per subsection 712.13.
624.03
Where class of pipe specified allows the use of metal pipe, its use will be limited per the resistivity requirements in Table 624-2. The Contract will state whether the resistivity requirements apply. Table 624-2 Resistivity Requirements for Metal Pipes Minimum Required Soil Side Resistivity, Soil Side Gauge Thickness for R (Ohm – cm) pH Metal Pipe Material 16 Gauge Aluminized ≥1500 5.0-9.0 Type 2 16 Gauge Polymer ≥250 3.0-12.0 Coated
The minimum wall thickness for metal pipe shall be the gauge shown on Standard Plan M-603-1 unless otherwise specified in the Contract. Joint systems for siphons, irrigation systems, and storm drains shall be watertight. Watertight joint systems for plastic pipe shall conform to subsection 705.02. Construction Requirements
624.03Installation shall conform to the requirements of Section 603 or Section 510 as
applicable. Installation for Aluminized Corrugated Steel Pipe Type 2 shall conform to all requirements for Corrugated Steel Pipe (CSP) including the fill height tables and requirements in Standard Plan M- 603-1. Joining and installation of plastic pipe shall conform to ASTM D2321 and the manufacturer's recommendations. Method of Measurement
624.04Drainage pipe will not be measured but will be the net length of pipe called for on the
plans, except when field changes are ordered or when there are errors on the plans. In case of exceptions, the quantity to be measured shall be the actual net length of conduit measured along the bottom centerline of the installed pipe. The net length shall include end sections when required.
Basis of Payment
624.05The accepted quantities of drainage pipe will be paid for at the contract unit price per
linear foot for the specified size and class.
Payment will be made under:
Pay Item Pay Unit _____Inch Drainage Pipe (Class__) Linear Foot
Structure excavation and structure backfill will be measured and paid for per Section 206.
624.05
This Page Intentionally Left Blank