SECTION 624 — Noise Barriers

624.1General Description

This work includes furnishing and installing a noise barrier wall, single and double steel doors and concrete pads according to this Specification and conforming to the locations, dimensions, lines, grades, and material type shown on the Plans. Types of noise wall material include the following: Type A Concrete masonry units Type B Interlocking steel panels Type C Precast concrete panels Type D Treated timber panels Type F Glass reinforced thermoset composite structural panels Type G Precast autoclaved aerated concrete (PAAC) panels Type H Absorptive panels Type I Reflective panels If a material type is not specified elsewhere in the Contract, then the noise barrier walls shall be constructed using precast concrete panels. Interlocking steel panels shall be used where a lighter weight material is necessary such as on bridges and retaining walls. A decision to use a noise barrier wall material other than precast concrete panels or interlocking steel panels, as noted above, will require written approval from the GDOT Chief Engineer. 624.1.01 Definitions General Provisions 101 through 150. 624.1.02 Related References

A.Standard Specifications
SECTION 106 — Control of Materials
SECTION 201 — Clearing and Grubbing Right-of-Way
SECTION 205 — Roadway Excavation
SECTION 206 — Borrow Excavation
SECTION 208 — Embankments
SECTION 210 — Grading Complete
SECTION 500 — Concrete Structures
SECTION 520 — Piling
SECTION 700 — Grassing
SECTION 702 — Vine, Shrub, and Tree Planting
SECTION 865 — Manufacture of Prestressed Concrete Bridge Members
SECTION 885 — Elastomeric Bearing Pads

1018 1018 1018 1018 1018

SECTION 624 — Noise Barriers
B.Referenced Documents

AASHTO LRFD Bridge Design Specifications AASHTO LRFD Bridge Construction Specifications GDT 7 GDT 20 GDT 21 GDT 24a GDT 24b GDT 59 GDT 67 QPL 9 QPL 42 QPL 53 QPL 90 Federal Specification QQ-S-763-C AASHTO ASTM M 31/M 31M M 32/M 32M M 111/M 111M M 270/M 270M A 153/153M A 366 A 526 A 568 A 569 A 572 A 591 A 653/653M A 792/792M B 695 B 766 C 90 C 1693 D 638 D 695 D 790 D 792 D 6386 D 2583 E 90 G 154 624.1.03 Submittals Submit to the Engineer shop drawings for noise barrier walls and steel doors for review and approval. Submission should be made electronically in a portable document format (pdf) and include an index. Format all drawings to fit 11 in. x 17 in. (279 mm x 432 mm) paper. Present calculations to fit 8.5 in. x 11 in. (216 mm x 297 mm) paper.

A.Noise Barrier Wall
1.Submit sketches and other data, that either verifies the wall will fit the final field conditions or indicates where

revisions are necessary, to the Engineer for review and approval. Submit this information prior to the creation of noise barrier wall shop drawings.

2.Prepare Shop Drawings for each Noise Barrier wall. Show all details necessary for field erection.

The minimum requirements are: • Complete elevation view showing the top and bottom elevations, the required wall envelope, the roadway grade, top of side barrier, top and bottom of footing of side barrier and ground line at the wall. • Diameter and depth of caissons at each post • Post size • Transitions between ground mounted and structure mounted noise barriers • Complete plan view with dimensions, stations and offset 1019 1019 1019 1019 1019

SECTION 624 — Noise Barriers
B.Steel Doors

Prepare Shop Drawings for a Single Steel Door and a set of Double Steel Doors. Show all details necessary for general construction, configurations, jointing methods, reinforcement, and anchorage meeting the following requirements: • Double steel exterior fire doors – 96 in. (2,438 mm) height by 36 in. (914 mm) width with latch bolt throws with two adjoined concrete pads - 18 ft. (5.49 m) length by 4 ft. (1.22 m) width by 6 in. (152 mm) depth concrete pad and 10 ft. (3.05 m) length by 4 ft. (1.22 m) width by 6 in. (152 mm) depth concrete pad • Single steel exterior door –84 in. (2,134 mm) height by 36 in. (914 mm) width with latch bolt throws with two adjoined concrete pads - 10 ft. (3.05 m) leng th by 4 ft . (1.22 m) width by 6 in. (152 mm) depth concrete pad and 4 ft. (1.22 m) length by 4 ft. (1.22 m) width by 6 in. (152 mm) depth concrete pad • Latch bolt throws - 38 in. (965 mm) to centerline of door knobs from top of finished concrete pad.

624.2Materials

Ensure other materials not listed herein meet the requirements of the appropriate Specification to which they pertain. Noise barriers shall meet the requirements of the following Specification, unless specified otherwise on the Plans or in the Special Provisions. For a list of approved noise barriers, see QPL 90. 624.2.01 Wind Loading Noise barrier panels shall be designed to the following wind speeds using a 700 Mean Recurrence Interval (MRI) for the listed counties: • 140 mph (Coastal 2): Bryan, Camden, Chatham, Effingham, Glynn, Liberty, McIntosh • 130 mph (Coastal 1): Brantley, Bulloch, Charlton, Evans, Long, Screven, Tattnall, Wayne • 120 mph (Piedmont 2): Appling, Bacon, Brooks, Burke, Candler, Clay, Clinch, Decatur, Early, Echols, Emanuel, Grady, Jeff Davis, Jenkins, Lowndes, Miller, Pierce, Seminole, Thomas, Toombs, Ware • 115 mph (Piedmont 1): For all counties not listed above The wind speeds and associated counties listed above result in the following minimum design wind pressures: Regions Strength III Service I Ground mounted Structure mounted

(psf)(psf) (psf)

Piedmont 1 24 29 15 Piedmont 2 38 44 15 Coastal 1 44 52 15 Coastal 2 59 70 15 624.2.02 Noise Reduction Noise barrier panels shall meet or exceeds the following criteria related to noise reduction: • Type A, B, D, F, G and I barriers must achieve a minimum weighted sound transmission loss of 20 dBA. The transmission or loss results must be based on the generalized truck spectrum when tested according to ASTM E 90. • Type H barriers must achieve a minimum noise reduction coefficient (NRC) of 0.8 and a minimum sound transmission class (STC) of 30 when tested according to ASTM C423. 1020 1020 1020 1020 1020

SECTION 624 — Noise Barriers

624.2.03 Component Materials

A.Type A- Concrete Masonry
1.Concrete Blocks shall be Class A Hollow Load Bearing Concrete Masonry Units, ASTM C90
2.Mortar shall conform to Section 834 of these Specifications
3.Design and erection shall conform with the requirements of the AASHTO LRFD Bridge Construction

Specifications, Section 15.

B.Type B- Interlocking Steel
1.Interlocking Steel Panels

Use cold formed configured steel panels that meet the following requirements:

a.Use steel sheet conforming to ASTM A 653/653M or ASTM A 792/792M Structural Steel (SS) Grade 50

Class 2 with a minimum thickness of 0.029 inches (0.74 mm)

b.Has a male-female rib that provides a friction interlock connection with adjacent panels or is joined

adequately according to the manufacturer’s specifications

c.Provides sufficient friction interlock connection strength to support its own weight without using

fasteners when connected to another panel and held in a vertical or horizontal position

d.Use a panel size and shape shown on the Plans or an alternate approved by the Engineer.
e.Coat (galvanize) the panels with either a G90 (Z275) weight of zinc according to ASTM A 653/653M or an

AZ50 (AZM150) weight of 55% aluminum-zinc alloy according to ASTM A 792/792M.

2.Protective Color Coating

Use one of the following coatings:

a.System A—The coating is polyvinylidene fluoride (70 percent resin, minimum enamel, PVF2).

1) Apply the coating system (including primer) at a total minimum film thickness of 1 mil (0.03 mm) per coated side. 2) Cure the polyvinylidene fluoride film to at least 0.8 mil (0.02 mm) film thickness.

b.System B—The coating is polyvinyl fluoride plastic film (PVF1) and has a thickness of at least 1.5 mils

(0.04 mm) coated on both sides. 1) Have the coating applied at the factory to thoroughly cleaned and pretreated galvanized steel according to ASTM D 6386. 2) Laminate the coating to the galvanized steel using heat and adhesive to form a uniform and durable coating pigmented to obtain optimum color performance. 3) Use a color from the Federal Standard Color Number indicated on the Plans. Ensure that caulking is color pigmented to match the wall color specified.

3.Posts

Use posts that meet the following requirements:

a.Hot rolled shape conforming to AASHTO M 270/M 270M GR 36/GR 250
b.Hot-dip galvanized by an approved galvanizer as listed on QPL-53 and in accordance with AASHTO M

111/M 111M

c.Coating that weighs at least 2 ounces/ft.

2 (610 g/m²) on all sides

d.Each post requires pre-inspection by the Office of Materials & Testing as evidenced by a GDT stamp

affixed near one end of each post. 1021 1021 1021 1021 1021

SECTION 624 — Noise Barriers
4.Steel Flashing and Caps

Use flashing and caps for steel walls of the same material and color coating as the panels. Fasten steel flashing and caps with self-tapping screws. Ensure that A-1 screws are Class #410 Stainless Steel and conform to Federal Specification QQ-S-763-C, or are cadmium coated according to ASTM B 766.

5.Fasteners

Attach panels to posts using a powder-actuated fastening system. Ensure fasteners are stainless steel or hot- dip galvanized as per ASTM A 153 Class C or have a mechanically deposited zinc coating as per ASTM B 695 Class 50.

C.Type C- Precast Concrete
1.Panels

Use precast concrete panels meeting the following requirements: Class AA Concrete or Self-Consolidating Concrete (SCC) Reinforcing AASHTO M 31/M 31M and M 32/M 32M If SCC is used the following shall be met: wet/cement ratio 0.40 min 3500 psi Spread Slump 24” ± 2”, Air Entrainment – min 3.5% to max 6.5%

2.Posts

Use posts that meet the following requirements:

a.Hot rolled shape conforming to AASHTO M 270/M 270M GR 36/GR 250
b.Hot-dip galvanized by an approved galvanizer as listed on QPL-53 and in accordance with AASHTO M

111/M 111M

c.Coating that weighs at least 2 ounces/ft.2 (610 g/m²) on all sides
d.Each post requires pre-inspection by the Office of Materials & Testing as evidenced by a GDT stamp

affixed near one end of each post.

3.Anchor bolts, nuts, washers and base plates
a.Use anchor bolts, nuts and washers meeting the requirements of Subsection 852.2, or ASTM F1554

Grade 36 (F1554M), A563 (A563M) and F436 (F436M), except use rolled threads meeting 8 UN/8 UNR thread profile according to ANSI B1.1. Use bolts with Class 2A threads, and nuts with class 2B threads. Galvanize all components in accordance with ASTM A 123/A123M or A153/A 153M, whichever is applicable.

b.Use galvanized base plates conforming to ASTM A709 Grade 36.
4.Elastomeric Bearing Pads

Use elastomeric bearing pads that conform to Section 885.

D.Type D- Treated Timber
1.Use treated timber panels meeting the following requirements:

Noise Barrier Walls See QPL 90 Class A Concrete Section 500 Lumber and Timber Section 860 Preservative Treatment of Timber Products Section 863 1022 1022 1022 1022 1022

SECTION 624 — Noise Barriers
E.Type F- Glass Reinforced Thermoset Composite
1.Structural Plank: Use continuous glass fiber reinforced structural planks meeting the following requirements:
a.Constructed of a durable, UV resistant, flame retardant, thermosetting composite material
b.Resistant to degradation from ozone, hydrocarbons, and freeze/thaw cycling
c.Matches the Federal Standard Color Number indicated on the Plans
d.Meets the following minimum mechanical properties:

PROPERTY MINIMUM VALUE TEST METHOD Flexural Modulus 2,200,000 psi (15200 MPa) ASTM D 790 Flexural Strength 70,000 psi (480 MPa) ASTM D 790 Tensile Strength 65,000 psi (450 MPa) ASTM D 638 Tensile Modulus 4,500,000 psi (31000 MPa) ASTM D 638 Elongation 1.5% ASTM D 638

Compressive Strength 60,000 psi (410 MPa) ASTM D 695

Barcol Hardness 50 ASTM D 2583

Specific Gravity 1.86 ASTM D 792

2.Filler: Use either hollow structural planks or planks filled with a recycled tire rubber compound comprised of

sorted and graded ground tire rubber (0.25 + 0.025 inch (6.4 + 0.6 mm)).

3.Flashing and Caps: Use flashing and caps of the same material and color as the panels.
4.Caulking: Use color pigmented caulking matching the wall color specified.
5.Posts

Use posts that meet the following requirements:

a.Hot rolled shape conforming to AASHTO M 270/M 270M GR 36/GR 250
b.Hot-dip galvanized by an approved galvanizer as listed on QPL-53 and in accordance with AASHTO M

111/M 111M

c.Coating that weighs at least 2 ounces/ft.

(610 g/m²) on all sides

d.Each post requires pre-inspection by the Office of Materials & Testing as evidenced by a GDT stamp

affixed near one end of each post.

5.Anchor bolts, nuts, washers and base plates
a.Use anchor bolts, nuts and washers meeting the requirements of Subsection 852.2, or ASTM F1554

Grade 36 (F1554M), A563 (A563M) and F436 (F436M), except use rolled threads meeting 8 UN/8 UNR

thread profile according to ANSI B1.1. Use bolts with Class 2A threads, and nuts with class 2B threads.

Galvanize all components in accordance with ASTM A 123/A123M or A153/A 153M, whichever is

applicable.

b.Use galvanized base plates conforming to ASTM A709 Grade 36.

10231023102310231023

SECTION 624 — Noise Barriers
F.Type G- Precast Autoclaved Aerated Concrete (PAAC)
1.Precast Autoclaved Aerated Concrete Wall Units: Use PAAC wall units cast from a mixture of Portland

cement, fine aggregate, water, gypsum, lime, and an expansion agent. After setting, and before hardening, the

PAAC is machine cut to the required size, then steam-cured under pressure in an autoclave. Use PAAC that

meets the following physical requirements:

a.Has a minimum average compressive strength of 725 psi (5000 kPa) when three specimens are tested in

accordance with ASTM C 1693, with no single specimen having a compressive strength of less than 580

psi (4000 kPa).

b.Has a maximum shrinkage of 0.02% when tested in accordance with ASTM C 1693
c.Has a dry bulk density between 34 lb./ft.

(544 kg/m

) and 41 lb./ft. (656 kg/m

) when tested in

accordance with ASTM C 1693

2.Reinforcing: Use reinforcing conforming to AASHTO M31/M 31M or M32/M 32M.
3.Posts

Use posts that meet the following requirements:

a.Hot rolled shape conforming to AASHTO M 270/M 270M GR 36/GR 250
b.Hot-dip galvanized by an approved galvanizer as listed on QPL-53 and in accordance with AASHTO M

111/M 111M

c.Coating that weighs at least 2 ounces/ft.

(610 g/m²) on all sides

d.Each post requires pre-inspection by the Office of Materials & Testing as evidenced by a GDT stamp

affixed near one end of each post.

4.Welds: Use welds as shown on the Plans.
5.Coatings: Use only approved coating systems on all exposed surfaces, including steel supports. Use the

same topcoat color on both the PAAC panels and the steel supports. Submit independent laboratory test

results for 1500 hours of accelerated weathering in accordance with ASTM G 154. Submit results that show

ratings of at least 9 in the following categories: color change, chalking, checking, cracking, blistering, flaking

and rusting. Submit a certification stating that the PAAC topcoat is graffiti resistant.

6.Anchor bolts, nuts, washers and base plates
a.Use anchor bolts, nuts and washers meeting the requirements of Subsection 852.2, or ASTM F1554

Grade 36 (F1554M), A563 (A563M) and F436 (F436M), except use rolled threads meeting 8 UN/8 UNR

thread profile according to ANSI B1.1. Use bolts with Class 2A threads, and nuts with class 2B threads.

Galvanize all components in accordance with ASTM A 123/A123M or A153/A 153M, whichever is

applicable.

b.Use galvanized base plates conforming to ASTM A709 Grade 36.
G.Type H- Absorptive
1.Noise Absorptive Panels
a.Constructed of a durable lightweight, UV resistant, flame retardant material. Provide manufacturer

certified wind load test report.

b.Resistant to degradation from ozone, hydrocarbons, and freeze/thaw cycling.
c.Matches the Federal Standard Color Number 16360(T-ROCK GREEN) or equivalent.
d.Free draining to prevent moisture buildup and possible corrosion.

10241024102410241024

SECTION 624 — Noise Barriers
2.Posts

Use posts that meet the following requirements:

a.Hot rolled shape conforming to AASHTO M 270/M 270M GR 36/GR 250
b.Hot-dip galvanized by an approved galvanizer as listed on QPL-53 and in accordance with AASHTO M

111/M 111M

c.Coating that weighs at least 2 ounces/ft

(610 g/m²) on all sides

d.Each post requires pre-inspection by the Office of Materials & Testing as evidenced by a GDT stamp

affixed near one end of each post.

3.Anchor bolts, nuts, washers and base plates
a.Use anchor bolts, nuts and washers meeting the requirements of Subsection 852.2, or ASTM F1554

Grade 36 (F1554M), A563 (A563M) and F436 (F436M), except use rolled threads meeting 8 UN/ 8UNR

thread profile according to ANSI B1.1. Use bolts with Class 2A threads, and nuts with class 2B threads.

Galvanize all components in accordance with ASTM A123/A123M or A 153/A 153M, whichever is

applicable.

b.Use galvanized base plates conforming to ASTM A709 Grade 36.
4.Other Materials
a.Use materials meeting the requirements of the appropriate Section in the Specifications to which they

pertain.

H.Type I- Reflective
1.Noise Reflective Panels
a.Constructed of a durable lightweight, UV resistant, flame retardant material. Provide manufacturer

certified wind load test report.

b.Resistant to degradation from ozone, hydrocarbons, and freeze/thaw cycling.
c.Matches the Federal Standard Color Number 16360 (T-ROCK GREEN) or equivalent.
d.Free draining to prevent moisture buildup and possible corrosion.
2.Post

Use posts that meet the following requirements:

a.Hot rolled shape conforming to AASHTO M 270/M 270M GR 36/GR 250
b.Hot-dip galvanized by an approved galvanizer as listed on QPL-53 and in accordance with AASHTO M

111/M 111M

c.Coating that weighs at least 2 ounces/ft.

(610 g/m²) on all sides

d.Each post requires pre-inspection by the Office of Materials & Testing as evidenced by a GDT stamp

affixed near one end of each post.

3.Anchor bolts, nuts, washers and base plates
a.Use anchor bolts, nuts and washers meeting the requirements of Subsection 852.2, or ASTM

F1554 Grade 36 (F1554M), A563 (A563M) and F436 (F436M), except use rolled threads meeting 8

UN/8 UNR thread profile according to ANSI B1.1. Use bolts with Class 2A threads, and nuts with

class 2B threads. Galvanize all components in accordance with ASTM A 123/A123M or A153/A

153M, whichever is applicable.

b.Use galvanized base plates conforming to ASTM A709 Grade 36.

10251025102510251025

SECTION 624 — Noise Barriers
I.Single and Double Steel Doors

Ensure materials meet the following:

1.Hot Rolled Steel Sheets and Strip: Commercial quality carbon steel, pickled and oiled, complying with ASTM

A-569 and ASTM A-568.

a.Cold-Rolled Sheets: Commercial quality carbon steel, complying with ATM A-366 and ASTM A-568.
b.Galvanized Steel Sheets: Zinc-coated or Zinc-Iron alloy-coated carbon steel sheets of commercial quality,

complying with ASTM A526, with ASTM A653, G-60 zinc coating, mill phosphatized. Use for all exterior

units.

c.Supports and Anchors: Fabricate of not less than 18 gauge galvanized sheet steel.
d.Inserts, Bolts and Fasteners: Manufacturer’s custom units, except hot-dip galvanized items to be built

into exterior walls, complying with ASTM A-153, Class C or D as applicable.

2.Protective Color Coating

Use one of the following coatings:

a.System A—The coating is polyvinylidene fluoride (70 percent resin, minimum enamel, PVF2).

1) Apply the coating system (including primer) at a total minimum film thickness of 1 mil (0.03 mm) per

coated side.

2) Cure the polyvinylidene fluoride film to at least 0.8 mil (0.02 mm) film thickness.

b.System B—The coating is polyvinyl fluoride plastic film (PVF1) and has a thickness of at least 1.5 mils

(0.04 mm) coated on both sides.

1) Have the coating applied at the factory to thoroughly cleaned and pretreated galvanized steel

according to ASTM D 6386.

2) Laminate the coating to the galvanized steel using heat and adhesive to form a uniform and durable

coating pigmented to obtain optimum color performance.

3) Use a color from the Federal Standard Color Number indicated on the Plans.

624.2.04 Delivery, Storage, and Handling

General Provisions 101 through 150.

624.3Construction Requirements

624.3.01 Construction

Perform the following work according to the Specifications:

A.Clearing and Grubbing

When necessary, clear and grub according to Section 201 as applicable.

B.Excavation, Borrow, Embankment

Perform excavation, borrow, and embankment according to Section 205, Section 206, Section 208, or Section

210. The scope and dimensions of the work are shown on the Plans.

C.Grassing

Perform grassing according to Section 700, as specified on the Plans.

D.Vine, Shrub, and Tree Planting

Plant vine, shrub, and trees according to Section 702 as specified on the Plans.

E.Miscellaneous Construction Items

When items are shown on the Plans but are not covered in this Specification, the Plans and Standard

Specifications to which they pertain govern the work. 10261026102610261026

SECTION 624 — Noise Barriers
F.Walls, Single and Double Steel Doors

Follow these requirements to construct each type of wall:

1.Type A Wall

When using hollow load bearing concrete masonry units (concrete block) to construct the walls, work

according to the notes, details, and dimensions on the Plans, including footings, reinforcement, and plaster

coat when required.

2.Type B Wall
a.Install steel noise barrier walls according to the manufacturer’s recommendations and Plan details.
b.Repair cut, scratched, or marred surfaces according to the manufacturer’s recommendations.
3.Type C Wall

When using precast concrete panels:

a.Cast panels at a precast concrete plant listed on QPL 9 or at a precast facility approved by the

Engineer.

b.Have the Engineer determine panel acceptability from the compressive strength of cylinders made

and cured the same as the panels and from inspection during manufacture.

Have the panel manufacturer furnish facilities and assistance to sample and test quickly and

satisfactorily.

c.Cast the panels on a steel surface with steel side forms.
d.Place concrete in each panel without interruption. Consolidate the concrete using vibrators

supplemented by hand tamping and rodding to force the concrete into the corners of the forms to

eliminate stone pockets, cleavage planes, and air bubbles.

e.Architectural finish required. Use the Ashlar Stone finish unless another architectural finish is

specified. Provide a similar architectural finish to the opposite side of the barrier unless noted

otherwise in the plans. Provide the same or similar finish on extensions of existing noise walls or

additions of new noise walls along a corridor with existing noise walls.

f.Cure the panels as specified in Subsection 500.3.05.Z.1, General Curing—Supplying Additional

Moisture, (wet cure) long enough for the concrete to develop the specified compressive strength.

1) Ensure that the curing period is at least 72 hours under normal summer temperature conditions.

In colder weather extend the curing period, as directed by the Engineer

2) Protect the panels from freezing from the time the concrete is placed until curing is complete.

3) Instead of the wet cure method, steam cure the panels as specified in Subsection

865.2.01.B.2.g.(2) if desired.

g.Mark each panel with the date cast and the Inspector’s approval stamp.

NOTE: Even with the Inspector’s acceptance at the precast yard, panels can still be rejected at

the erection point if they are damaged.

h.Erect the panels according to Plan details and dimensions. Place bearing pads as shown in the Plans,

and tighten the restraining bolts. Do not stack more than two bearing pads at the panel support. Do not

use concrete blocks at the panel supports to make up for grade difference on top of foundation.

i.After erection is complete and before Final Acceptance of the Project, clean the noise barrier to remove

dirt or stains. 10271027102710271027

SECTION 624 — Noise Barriers
4.Type D Wall

Install in accordance with manufacturer’s recommendations and plan details. Do not install walls with burns,

discolorations, cracks, or other objectionable marks that would adversely affect the performance of the

system.

5.Type F Wall

Install in accordance with manufacturer’s recommendations and Plan details. Do not install walls with burns,

discolorations, cracks, or other objectionable marks that would adversely affect the performance of the

system.

6.Type G Wall
a.Cast the PAAC panels in a precast facility approved by the Engineer.
b.Have the Engineer determine panel acceptability from the compressive strength of cylinders made and

cured the same as the panels and from inspection during manufacture. Have the panel manufacturer

furnish facilities and assistance to sample and test quickly and satisfactorily.

c.Cast the panels on a steel surface with steel side forms. When an architectural finish is specified for one

side of the barrier, provide a similar finish to the opposite side unless noted otherwise in the plans.

d.Place concrete in each panel without interruption. Consolidate the concrete using vibrators supplemented

by hand tamping and rodding to force the concrete into the corners of the forms to eliminate stone

pockets, cleavage planes, and air bubbles.

e.After machine cutting to the required size, cure the PAAC units by high-pressure steam autoclaving so

that the units meet the physical requirements of Subsection 624.2.03.F.1.

f.Mark each panel with the date cast and the Inspector’s approval stamp.

NOTE: Even with the Inspector’s acceptance at the precast yard, panels can still be ejected at

the erection point if they are damaged.

g.Erect the panels according to Plan details and dimensions.
h.After erection is complete and before Final Acceptance of the Project, clean the noise barrier to remove

dirt or stains.

i.Use coatings that are approved by the Laboratory.

1) PAAC panels. Apply the coating with a sponge-textured roller in accordance with the manufacturer’s

recommendations. Cover all exposed galvanized steel surfaces for protection from splattering. Apply

the coating at a minimum thickness of 60 dry mils (1.5 mm). Apply the coating only when the ambient

temperature is greater than 40 o F (4 o C) and rising. Do not apply any coating during rainfall or when

rainfall is forecast overnight.

2) Galvanized Steel Supports. Apply a corrosion resistant coating by brush, roller, or airless spray in

accordance with the manufacturer’s recommendations. Protect the adjacent PAAC surfaces from

overspray. Apply the coating at a minimum thickness of 2 dry mils (0.05 mm). Use a color that

matches the PAAC final topcoat color. Apply the coating only when the ambient temperature and

relative humidity fall within the limits stated by the manufacturer.

7.Type H Wall

Install in accordance with manufacturer’s recommendations and Plan details. Do not install walls with burns,

discolorations, cracks, or other objectionable marks that would adversely affect the performance of the

system. Ensure to install panels with the absorptive portion facing the highway side.

8.Type I Wall

Install in accordance with manufacturer’s recommendations and Plan details. Do not install walls with burns,

discolorations, cracks, or other objectionable marks that would adversely affect the performance of the

system. Ensure to install panels with the reflective portion facing the highway side. 10281028102810281028

SECTION 624 — Noise Barriers
9.All Walls

Before beginning earthwork on the Project, stake the noise barriers in the field and establish the final ground

line elevations at the noise barrier walls.

After wall stake out data has been reviewed and approved by the Engineer per subsection 624.1.03, furnish

these elevations to the supplier who will develop the shop plans per subsection 624.1.03.A.

a.Protect the final ground elevations established in the field for the duration of the Project. Do not adjust

them without the Engineer’s approval.

b.Install noise barriers according to the Plans and Shop Drawings approved by the Engineer.
c.Secure joints and connections to be structurally sound with no visible openings for sound transmission.

Ensure that vibration from metal barriers is not a secondary source of noise transmission.

d.Repair marred, chipped, scratched, or spalled barrier areas according to the manufacturer’s

recommendations and as directed by the Engineer at the Contractor’s expense.

e.To substitute welded for fixed-bolt connections or vice versa on metal barriers and doors, meet these

conditions:

1) Submit load calculations for the specific connection to be modified.

2) Use a safety factor of at least 3.0.

f.Place trench backfill for noise barrier construction according to Section 207. Use select material to

backfill.

If the Engineer believes the trench is too narrow for compaction, backfill the trench excavation with

concrete grout to the Engineer’s satisfaction. No additional compensation will be made for the concrete

grout.

g.Dispose of excess excavation to the Engineer’s satisfaction.
h.Keep right-of-way fence scheduled to be salvaged in place until the noise barrier is constructed, or as

long as the Engineer deems practical.

i.After erecting the noise barrier, leave the disturbed area in a finished condition at the Engineer’s direction

and plant grass or sod.

j.Payment for establishing grass is described in Subsection 624.4.C, “Grassing.”
k.Ensure noise barrier meets these tolerances:

1) Vertical alignment for barriers and posts is:

• 0.5 in. (15 mm) for noise barrier heights to 10 ft. (3 m)

• 1 in. (25 mm) for noise barrier heights to 20 ft. (6 m)

• 1.5 in. (40 mm) for noise barrier heights to 30 ft. (9 m)

2) Horizontal alignment for noise barriers is close to that shown on roadway Plans.

3) Post spacings are within 0.5 in (15 mm) of their intended location.

l.For noise barriers built on top of earth berms, construct the berms of earthwork fill material and compact

to 95% of the maximum density as determined by GDT 7, GDT 24a, GDT 24b or GDT 67, as applicable.

Determine in-place density according to GDT 20, GDT 21, or GDT 59, as applicable.

m.Tolerance for Type C and G Panels

1) Manufacture Type C and G panels within the dimensional tolerances for Flat Wall Panels listed in

SOP-3, Standard Operating procedures for Precast/Prestressed Concrete.

2) The Department may reject noise wall panels based on excessive deviations.

3) For textured finished, surface defects greater than 5/16 in. (8 mm) in 5 ft. (1.5 m) will be rejected. 10291029102910291029

SECTION 624 — Noise Barriers
10.Single and Double Steel Doors
a.Install single and double steel doors according to the manufacturer’s recommendations, the Plans,

and Shop Drawings approved by the Engineer.

b.Furnish the elevations and locations to the supplier who will develop the Shop Plans, including a

complete elevation view of each single and double steel door set indicating the locations and the

concrete pad top elevation.

G.Graffiti-Proof Coating

This work includes providing graffiti-proof coating on both faces of concrete and masonry noise barriers, and

single and double steel doors from the ground line to the top of the wall.

1.Materials. Use materials as noted on QPL 42.
2.Delivery and Storage. Ensure that the materials are delivered in manufacturer’s original containers with labels

intact.

Store the materials out of the weather, in a single location, and as specified by the manufacturer.

3.Job Conditions. Protect the coating from the weather and work conditions as follows:
a.Apply the graffiti-proof coating in weather recommended by the manufacturer.
b.Mask, cover, or otherwise protect finished adjacent surfaces from damage that work in this Section could

cause.

c.Protect finished coatings from staining, marring, and damages from other trades.
4.Quality Criteria. Use materials that are products of one manufacturer.

Use application equipment recommended or approved by the coating manufacturer for use on this Project.

Use equipment in good operating condition.

5.Application. Ensure that the moisture content of surfaces to receive coating are within the limits

recommended by the coating manufacturer.

a.Apply coating after applying a Type III finish of concrete, or after thoroughly cleaning the concrete block.
b.Apply coating at rate of 1 gal per 250 to 300 ft.² (1 L per 6 to 7 m²). Apply three coats using a low-

pressure spray.

c.Begin the coating application at the uppermost surfaces and work down.
d.Remove loose particles, dirt, grease, oil, and other foreign materials following application.

624.3.02 Quality Acceptance

The panels are subject to rejection if they fail to meet the requirements specified above. The following defects are also

cause for rejection:

1.Defects from imperfect mixing and casting
2.Honeycombed or open texture
3.Exposed reinforcement
4.Failure to meet the required 3,500 psi (25 MPa) compressive strength at 28 days

10301030103010301030

SECTION 624 — Noise Barriers

624.4Measurement

A.Clearing and Grubbing

Clearing and grubbing will not be measured separately for payment.

B.Excavation, Borrow, and Embankment

Excavation, borrow, and embankment will not be measured for payment unless an earthwork pay item is included

in the contract.

The scope and dimensions of the work are as shown on the Plans.

C.Grassing

Grassing is not measured separately for payment unless shown on the Plans as a payment item.

D.Vine, Shrub, and Tree Planting

Vine, shrub, and tree planting shown on the Plans is measured according to Section 702.

E.Items Not Covered in This Specification

Items shown on the Plans but not covered in this Specification are measured for payment according to the

applicable portions of the Specifications.

F.Walls
1.Type A Wall

Concrete masonry wall constructed of concrete masonry units (blocks), complete in place, is measured in

square feet (meters) of area from end to end and from top of footing to top of wall, including solid top block or

solid cap block.

2.Type B Wall

Steel wall is measured in square feet (meters) of wall surface installed before backfilling complete in place

according to Subsection 109.01, Measurement and Quantities. There will be no separate measurement for

posts, flashing, caps, concrete post embedment, or other incidental items required for construction.

3.Type C Wall

Precast concrete noise barriers are measured in square feet (meters) of wall surface before backfilling,

including pile flanges, complete in place and accepted.

There will be no separate measurement pile, anchor bolts, plates, connections, neoprene bearing pads,

connecting bolts, or other components of the noise barrier.

4.Type D Wall

Treated timber walls are measured in square feet (meters) of wall surface installed before backfilling.

No separate measurement is made for posts, caps, foundations, footings, hardware, timber treatment,

pile, or over boards.

5.Type F Wall

Glass reinforced thermoset composite structural panel walls are measured in square feet (meters) of wall

surface installed before backfilling complete in place in accordance with Section 109.

There will be no separate measurement for posts, top caps, bottom caps, side caps, flashing, strip

seals, mounting brackets and hardware, concrete post embedment, or other incidental items required

for construction.

6.Type G Wall

Precast Autoclaved Aerated Concrete walls are measured in square feet (meters) of wall surface installed

before backfilling, complete in place and accepted.

There will be no separate measurement for steel supports or any other components of the noise barrier. 10311031103110311031

SECTION 624 — Noise Barriers
7.Type H Wall

Absorptive panel walls are measured in square feet (meters) of wall surface before backfilling complete

in place and accepted. There will be no separate measurement for steel post or any other components

of the noise barrier.

8.Type I Wall

Reflective panel walls are measured in square feet (meters) of wall surface before backfilling complete in place

and accepted. There will be no separate measurement for steel post or any other components of the noise

barrier.

624.5Payment

The pay quantities will be the Wall Envelope quantities shown in the Plans unless the Engineer approves an adjusted

wall envelope. In this case, the pay quantities will be the adjusted wall envelope quantities.

No additional compensation will be made for any additional material, equipment, design, or other items found

necessary to comply with the project Specifications as a result of the Department's review except for changes made

necessary by the survey verification required by Subsection 624.1.03 and Subsection 624.3.01.F.9, or other changes

approved by the Engineer.

Include in the unit bid prices all costs necessary to comply with the requirements of this specification. No payment will

be made for wall area outside of the adjusted wall envelope.

A.Clearing and Grubbing

The cost of clearing and grubbing is included in the Lump Sum Clearing and Grubbing Item for the Project. When

clearing and grubbing is not shown as a payment Item, the cost is included in the overall Contract Price for the

work covered in this Specification.

B.Unclassified Excavation and Borrow

No separate payment will be made for Excavation, Borrow and Embankment unless shown on the Plans as a

separate Pay Item.

C.Grassing

No separate payment will be made for Grassing unless shown on the Plans as a separate pay item.

D.Vine, Shrub, and Tree Planting

When the Plans state that this Item will be paid for, payment will be made under Section 702.

E.Items Not Covered by This Specification

Items shown on the Plans to be paid for but are not covered by this Specification will be paid for according to the

applicable portions of the Specifications.

F.Walls
1.Type A Wall
a.Concrete block walls will be paid for at the Contract Unit Price bid per square foot (meter). Payment

includes but is not limited to: Concrete blocks of the thickness shown on the Plans for the wall and

pilasters.

b.Plaster coat when required
c.Excavation for footings, concrete footings, and reinforcement when specified
d.Incidentals to complete the Item, including graffiti-proof coating
2.Type B Wall

Steel wall will be paid for at the Contract Unit Price bid per square foot (meter). Payment is full compensation

for furnishing and installing materials, providing post and post embedment, and providing labor, equipment,

and incidentals to complete the Work. 10321032103210321032

SECTION 624 — Noise Barriers
3.Type C Wall

Precast concrete noise barrier will be paid for at the Contract Unit Price bid per square foot (meter). Payment

is full compensation for furnishing materials, including piling and attachments and for erecting the noise

barrier, including graffiti-proof coating.

4.Type D Wall

Treated timber wall will be paid for at the Contract Unit Price bid per square foot (meter). Payment is full

compensation for furnishing materials including concrete and steel and for erecting the noise barrier.

5.Type F Wall

Glass reinforced thermoset panel walls will be paid for at the Contract Unit Price bid per square foot (meter).

Payment is full compensation for furnishing and installing materials, including post and post embedment, and

for labor, equipment, and incidentals to complete the Work.

6.Type G Wall

Precast autoclaved aerated concrete noise barrier will be paid for at the Contract Unit Price bid per square

foot (meter). Payment is full compensation for furnishing materials, including steel supports, and for erecting

the noise barrier, including graffiti-proof coating.

7.Type H Wall

Absorptive wall will be paid for at the Contract Unit Price bid per square foot (meter). Payment is full

compensation for furnishing and installing materials, post and post embankment, labor, equipment, and

incidentals to complete the Work.

8.Type I Wall

Reflective wall will be paid for at the Contract Unit Price bid per square foot (meter). Payment is full

compensation for furnishing and installing materials, post and post embankment, labor, equipment, and

incidentals to complete the Work.

Payment will be made under:

Item No. 624 Noise barrier type ___, Ground Mounted Per square foot (meter).

Item No. 624 Noise barrier type ___, Structure Mounted Per square foot (meter).

624.5.01 Adjustments

General Provisions 101 through 150.. 1033 1033 1033 1033 1033