strength and steel reinforcement to resist jacking forces and shall have tongue and groove joints. All reinforced concrete pipes shall have steel reinforcement concentric with the pipe wall. Steel pipe used as a carrier pipe shall have the following minimum wall thickness. 100 Steel pipe used as a casing pipe, but not used as a carrier pipe, shall be selected by the Contractor to have minimum wall thickness sufficient to resist jacking forces. For installations where the casing is not used as a carrier but only as a casing for a carrier pipe, the thickness of the casing shall be determined by the Contractor. Outside Diameter, in. Wall Thickness, in. 18 or less 1/4 19 – 20 5/16 21 – 26 3/8 27 – 30 1/2 31 – 42 1/2 43 – 48 9/16 CONSTRUCTION REQUIREMENTS
716.03 General Requirements
The Contractor shall submit a QCP in accordance with ITM 803. The QCP shall 110 be submitted to the Engineer for review and acceptance, at least 15 days prior to the start of trenchless pipe installation operations. Where groundwater is known or anticipated, and where the technique selected for trenchless pipe installati on does not provide positive s upport at the trenchless excavation face, such as by slurry support in microtunneling, then trenchless pipe installation shall not proceed without dewatering in advance of trenchless pipe installation. A dewatering system of sufficie nt capacity to handle the flow shall be maintained at the site until its operation can be safely halted. The dewatering system shall be equipped with screens or filter media sufficient to prevent the displacement of 120 fines. Where the use of explosives is necessary for performing the work, their use shall be in accordance with 107.13. Bentonite or other suitable lubricants may be applied to the outside surface of the pipe to reduce frictional forces. Joints in steel pipe shall be watertight. Where welded joints are utilized, they shall be welded in accordance with 711.32. Joints in concrete pipe or other jacking pipe 130 materials, including clay pipe, shall be designed to withstand the additional forces that 716.03 752 are created in the joints during the installation process. The joints in concrete pipe or other pipe jacking materials shall be protected with a resilient material around the circumference of the pipe. Resilient material shall also be used between the pipe and the thrust ring. Pavement or ground surface heave or settlement resulting in damage to pavement, existing utilities, or structures above the installation will not be allowed. To confirm if heave or settlement is occurring, the Contractor shall undertake surface monitoring. Installations shall have a bored hole esse ntially the same diameter as the outside of the installed pipe. If voids develop or if the bored diameter is greater than the outside diameter of the pipe by more than 1 in., grouting shall be used to fill such voids. When the installation is 4 in. or larger and the casing is used as the carrier pipe, a visual or a video inspection shall be performed using a high resolution, high sensitivity color video camera and recording equipment. The pipe shall be cleaned of debris prior to the inspection. Cleaning shall be accomplished by means of water jetting or other approved methods. 150 The camera and recording equipment shall be specifically designed for continuous viewing and recording of detailed images of the interior wall of pipes and transitions of the specified sizes. The equipment shall include sufficient lighting to view the entire periphery of the pipe. The equipment shall have appropriate attachments to maintain a position in the center of the pipe and an electronic counter to continuously record the location of the equipment in the pipe. A c opy of the video inspection shall be submitted to the Engineer. All sections of pipe found to be damaged or where joint failure is evident shall be repaired or replaced as approved by the Engineer. 160 If an obstruction is encountered during installation which stops the forward progress of the pipe, and it becomes evident that it is impossible to advance the pipe, the Engineer shall be notified. For installa tions utilizing tunnel shields or tunnel-boring machines or other methods that allow acces s to the face, the obstruction shall be removed in accordance with the QCP. For in stallations utilizing methods that do not allow access to the face, at th e direction of the Engineer, the pipe shall be abandoned in place and filled with grout or other approved materials. Where a gravity-flow carrier pipe is pl aced inside a casing pipe, the gravity-flow 170 carrier pipe shall be shimmed to proper line, elevation, and grade and then the void between the two pipes shall be grouted with cellular grout. Upon completion of the installation of the pipe, all excavated areas not occupied by the pipe shall be backfilled and compacted with suitable material in accordance with 203. 716.03 753 716.04 Method of Measurement Pipe installed by means of trenchless installation methods will be measured by the linear foot along the center line of the pipe installed. 180
716.05 Basis of Payment
Pipe installed by means of trenchless in stallation methods will be paid for by the linear foot for pipe installation, trenchless, of the size specified, complete and in place including all incidentals. Removal of boulders, concrete, or other obstructions will be paid in accordance with 104.03. Payment will be made under: 190 Pay Item Pay Unit Symbol Pipe Installation, Trenchless, _____ .......................................... LFT size The cost of the QCP, excavating and backfilling of the drive shaft and reception shaft, video inspection, camera and recording equipment, bentonite or other lubricant, grout, and the casing if installed shall be included in the cost of pipe installation, trenchless. 200 If a partial installation has to be aba ndoned in place and filled with grout due to the encountering of an obstruction, the abandoned work will be paid for at 75% of the contract unit price of the pipe installed. No payment will be made to repair or replace sections of pipe that have been damaged or show evidence of joint failure.