Incidentals (Items 600-699)

613High Mast Illumination Poles

TX · 2024 Standard SpecificationsBook pages 860863View official source ↗

Article 1 — Description

Furnish and install high mast illumination poles.

Article 2 — Materials

Provide new materials that comply with the details shown on the plans and the requirements of this Item and the following Items .  Item 416, “Drilled Shaft Foundations”  Item 421, “Hydraulic Cement Concrete”  Item 432, “Riprap”  Item 441, “Steel Structures”  Item 442, “Metal for Structures”  Item 445, “Galvanizing”  Item 449, “Anchor Bolts”  Item 618, “Conduit” Use alloy steel or medium strength mild steel anchor bolts that comply with Section 449.2.1., “Bolts and Nuts.”

Article 3 — Construction

Perform work as shown on the plans and in accordance with this Item. Provide components that fit together properly. Use established industry and utility safety practices when installing high mast poles located near overhead or underground utilities. Consult with the appropriate utility company before beginning work.

3.1 Standard Design . Fabricate poles in accordance with this Item and the plans. Alternate designs are not

permitted.

3.2 Shop Drawings . Do not submit shop drawings for high mast illumination poles fabricated in accordance with

this Item and the plans .

3.3 Fabrication . Fabricate and weld in accordance with Item 441, AWS D1.1, and this Item. Match- mark pole

shaft sections as shown on the plans . Fabrication plants that produce high mast illumination poles must be approved in accordance with DMS -7380 , “Steel No n-Bridge Member Fabrication Plant Qualification.” The Materials and Tests Division maintains an MPL of approved high mast illumination pole fabrication plants . Provide circumferential welds only at the top attachment and base plates. Grind or smooth the longitudinal seam welds to the same radius as contacted shaft corners for the length of the lap plus at least 6 in. at each slip-joint splice. Ensure acceptable seam weld profiles for the remainder of the pole shaft . Provide full penetration longitudinal seam welds for a length of 1.5 diameters plus at least 6 in. in outer sections at splices and base plates. Provide 85% minimum penetration in longitudinal seam welds at other pole sections. 851 Perform at least 10% ultrasonic testing (UT) of longitudinal seam wel ds using a Department -approved procedure to ensure 85% minimum penetration where specified. Perform testing at a minimum of three locations on each shaft (top, middle, and bottom). The minimum length of each test area must be 10 in. If minimum penetration is not achieved in any of the tested areas, test an additional 24 in. beyond the originally selected test areas requiring 85% penetration. Test the entire shaft seam weld if any locations within the additional 24 in. test areas do not achieve 85% penetrati on. Repair the deficient areas using a Department - approved repair procedure and retest to confirm minimum penetration. Provide longitudinal seam weld and fit-up that will minimize acid entrapment during later galvanizing. Use at most two longitudinal seam welds in each section. Permanently mark each pole base plate with the insignia of the fabrication plant. Place the mark on the pole base plate adjacent to the handhole access compartment. Hot-dip galvanize fabricated pole sections and associated parts in accordance with Item 445. Provide punched, drilled, or mechanically guided thermal -cut holes in steel parts or members, when allowed, before galvanizing. Mechanically guided thermal -cut hole quality will be in accordance with Item 445. Fabrication tolerances are shown in Table 1. Perform UT of the shaft to base plate weld joint after galvanizing with a Department -approved procedure to determine if any toe cracks are present in the ground sleeve. Remove and repair toe cracks with an approved repair procedure and retest. Table 1 Fabrication Tolerances Part Dimension Tolerance (in.) Pole shaft Length (unassembled sections) ±1 Shaft thickness1 +0.12, -0.02 Inside diameter of outside slip fitting +1/8, -1/16 Outside diameter of inside slip fitting +1/32, -1/8 Difference between flats or diameter2 ±1/4 Straightness 1/8 in 10 ft. Attachment locations ±1 Assembled pole shaft Perpendicular to base plate 1/8 in 24 in. Shaft centered on base plate ±1/4 Twist in shaft3 4° in 100 ft. Position of winch channel ±1/4 Base plate Overall ±1/4 Thickness +1/4, -1/16 Deviations from flat 3/16 in 24 in. Spacing between holes ±3/16 Bolt hole size ±1/16 Anchor bolt templates Outside diameter ±1/8 Inside diameter +1/4 Thickness +1/4, -1/32 Spacing between holes ±1/16 Bolt hole size ±1/16 Anchor bolts Length ±1/2 Threaded length ±1/2 Galvanized length -1/4 Miscellaneous Bolt hole spacing ±1/16 1. Adjust pole diameter if shaft thickness exceeds nominal thickness by 0.02 in. or more. Change the splice length for this adjustment. 2. Applies only to bottom end of bottom shaft section, and top end of the top shaft section. 3. The Department may accept an excessive twist for individual pole sections , provided the top of pole is within twist tolerance for assembled sections.

3.4 Installation . Stake and install high mast illumination poles as shown on the plans. The Engineer may shift

the assembly locations, within design guidelines, where necessary to secure a more desirable location or to avoid conflict with utilities . 852 Use established industry and utility safety practices when installing poles located near overhead or underground utilities. Consult with the appropriate utility before beginning work. Prevent scarring or marring of the poles. Repair galvanized surfaces damaged in assembly, transit, or installation, or for steel parts or members welded after galvanizing, in accordance with Section 445.3. 4., “Repairs.” Provide riprap around pole foundations in accordance with Item 432 and as shown on the plans.

3.4.1 Foundations . Construct foundations for high mast illumination poles in accordance with Item 416 and as

shown on the plans . Before placing concrete for the drilled shaft foundation, inspect anchor bolts to verify proper projecting length of bolts, bolt pattern, orientation of pattern, bolt alignment, and bolt galvanizing are as shown on the plans. Orient anchor bolts to provide two bolts on the reference line as shown on the plans. Ensure the anchor bolts are electrically bonded to the reinforcing steel as shown on the plans. Ensure anchor bolts and templates are rigidly held in position during concrete placement. Positioning devices may be tack welded to steel template, but not to any portion of the anchor bolts. Hold conduit in place with a bar attached to the upper template and cap conduit before placing concrete. Ream conduit to remove burrs and sharp edges after placing concrete. Install bell ends or bushings on the conduit.

3.4.2 Pole Assembly. Assemble poles on blocking using at least two hydraulic rams at the splices. Support the

free end of the section being assembled using hoist equipment. Apply assembly force using hydraulic rams with sufficient capacity to properly draw the sections together with little or no remaining gaps. Mark poles with permanent ink to indicate designed lap length. Ensure splices are a minimum of 90% or a maximum of 110% of the planned lap. Mark the 90% and 110% locations before assembling the pole. Obtain written approval from the Department for splices that do not meet lap tolerances before erecting the pole.

3.4.3 Pole Installation . Install structures after foundation concrete has attained its design strength as shown on

the plans and in accordance with Item 421. Coat anchor bolt threads and tighten anchor bolts in accordance with Item 449. Erect and align the poles within 12 in. of vertical. Use enough temporary slings, chains, or wire rope to prevent unintentional separation of the pole sections. Orient poles so a worker can see into the access hole while facing oncoming traffic . After the high mast pole has been plumbed and all nuts are tight, tack weld each anchor bolt nut to its washer in two places and tack weld each washer to the base plate in two places. Tack weld in accordance with Item 441, AWS D1.1, and this Item. Never weld components to the bolt. Repair galvanizing damage on bolts, nuts, and washers in accordance with Section 445.3. 4., “Repairs,” after tack welding. Do not grout between the base plate and foundation .

Article 4 — Measurement

This Item will be measured as each high mast illumination pole installed.

Article 5 — Payment

The work performed and materials furnished in accordance with this Item and measured as provided under “Measurement” will be paid for at the unit price bid for “High Mast Illumination Poles” of the wind design and height specified. This price is full compensation for furnishing, fabricating, galvanizing, assembling, and installing the pole on a foundation; anchor bolts, nuts, washers, and templates; conduit, ground rods, and wiring; and materials, equipment, labor, tools, and incidentals. New drilled shaft foundations will be paid for under Item 416. New riprap will be paid for under Item 432. New high mast illumination assemblies will be paid for under Item 614, “High Mast Illumination Assemblies.” New 853 ground boxes will be paid for under Item 624, “Ground Boxes.” New electrical services will be paid for under Item 628, “Electrical Services.”