Effective with the December 2018 Letting 337 2019 Standard Spec ifications Section 608 Storm Sewer
608.1Description
608.2Materials
608.2.1 Pipe
classes of pipe as follows: TABLE 608-1 ALLOWABLE MATERIALS FOR STORM SEWER CLASSES
CLASS ALLOWABLE MATERIALS II Class II reinforced concrete III Class III reinforced concrete III-A Class II and Class III reinforced c oncrete, corrugated polyethy lene, corrugated polypropylene III-B Class III reinforced concrete , corrugated polypropylene IV Class IV reinforced concrete V Class V reinforced concrete
Circular reinforced concrete pipe ............................. ............................................................... ..... AASHTO M170 Horizontal elliptical rei nforced conc rete pipe ................ ............................................................... AASHTO M207 Corrugated polyeth ylene pipe .................................. ............................................................... .. AASHTO M294 S Corrugated polypro pylene pipe ................................. ............................................................... . AASHTO M330 S Composite pipe, couplings, fitti ngs and joint materials ....... ............................................................ ASTM D2680 Joints using ru bber gaske ts .............................................................................................................. ASTM C443 Joints using preformed fl exible joint sealants ................ ................................................................... ASTM C990 External rubber gaskets, mastic, and protective film ......................................................................... ASTM C877 Mortar ........................................................ ............................................................................................... 519.2.3
fabricators on the department's APL. Conform to the specified AASHTO m aterials requirements for th e class of pipe specified except as follows: - Use concrete with 565 pounds or more cementitio us material pe r cubic yard. - The contractor may use cement conforming to 501.2.1 or may substitute for portl and cement a t the time of batching conforming to 501.2.6 for fly ash, 501.2.7 for slag, or 501.2.8 for other pozzolans. In either case the maximum total supplementary cementitious content is limited to 30 percent of the to tal cementitious content by weight.
enables application to joints with a trowel if air temperatures range from 20 to 100 F. 608.2.2 Backfill 608.2.2.1 General
gravel, crushed gravel, or crushed stone. Do not use materials classified under 301.2.4.3 as crushed concrete, reclaimed asphalt, repr ocessed material, and blended material. The contractor may use material from the work site.
than or equal to 6.
Sampling[1] ............................................................................................................................. ........... AASHTO T2 Percent passing t he 200 sieve ................................. ............................................................... ........ AASHTO T11 Gradation[1] ............................................................................................................................. ........ AASHTO T27 Liquid l imit .................................................. ............................................................... ...................... AASHT O T89 Plasticity index and plastic limit ............................ ............................................................... ........... AASHTO T90 [1] As modified in CMM 8-60.
Effective with the December 2018 Letting 338 2019 Standard Spec ifications (4) Submit contractor test results for gradation, liquid limit, an d plasticity index testing to the engineer for approval before placing backfill . The engineer may waive contra ctor testing for known sources.
engineer. Determine quantities at the point of placement by collecting truck tickets as the material is placed or by another engineer-approved method.
prevent segregation and achieve adequate compaction. 608.2.2.2 Foundation Backfill
- A minimum of 85 percent by c ount of the number of particles h ave at least one machine-fractured face. - Gradation conforming AASHTO M43 as follows: PERCENT PASSING BY WEIGHT SIEVE AASHTO No. 8 AASHTO No. 67 (for pipes <= 18-inch diameter) (for pipes > 18- inch diameter ) 1-inch ___ 100 3/4-inch ___ 90 - 100 1/2-inch 100 ___ 3/8-inch 85 - 100 20 - 55 No. 4 10 - 30 0 - 10 No. 8 0 - 10 0 - 5 No. 16 0 - 5 ___ 608.2.2.3 Trench Backfill
608.3Construction
608.3.1 Excavation 608.3.1.1 General
trenches and in a way that protects pipelines or sewers from un usual stresses.
sewer pipe before excavating the trench. Perform trenching, sho ring, and excavating according to 29 CFR part 1926, OSHA su bpart P. If utilities and other restraints make sloping or benching of the excavation impracticable, employ a shoring system. http://www.dol.gov/dol/cfr/title_29/
not exceed 1/2 the nominal diame ter of the pipe, and never be l ess than 6 inches. The required working space shall depend upon the size of the pipe and the ch aracter of the material in the excavation; however, always provide sufficient space between the pipe and the sides of the trench to allow for preparing the foundation, laying the pipe, and placing and compacting the backfill. If the height of the proposed embankment o r earth cover above the top of the pipe exceeds 6 feet, excavate the trench below the top of the pipe as vertical as possible.
and placing and compacting bac kfill, except that the trench wid th shall not exceed the pipe's outside diameter by more than 36 inches. For polyethylene and polypropy lene pipe, conform to ASTM D2321 and ensure that the tr ench is as wide or wider than the pipe outside diameter plus 16 inches or the pipe outside diameter times 1.25 pl us 12 inches whichever is wi der.
the field. Begin trench excavati on at the proposed sewer outlet and proceed toward the upper end.
jacking instead of open trenchi ng. Adhere to the construction d etails the plans show, the contract specifies or the engineer establishes.
Effective with the December 2018 Letting 339 2019 Standard Spec ifications (8) Understand that the inlet and disc harge elevations for storms ewers the plans show, are subject to revisions in order to fit field conditions, and the engineer ma y adjust the profile grades from those the plans show.
the completed work. Backfill displaced areas with material conf orming to 608.2.2 and place foundation backfill conforming to 608.3.2 and place trench backfill conforming to 608.3.5 . 608.3.1.2 Rock Excavation for Storm Sewer
rock boulders with a volume of 1/2 cubic yard or more. 608.3.1.3 Excavation for Relaid Storm Sewer
Replace pipe designated for reuse that is made unusable through the contractor's operations. Excavate trenches to reinstall storm sewer conforming to 608.3.1.1 and 608.3.1.2 . Backfill conforming to 608.3.5 . 608.3.2 Constructing Foundation
Backfill to this depth with foundation backfill. Mechanically c ompact foundation backfill before laying 12 inches above the pipe to provide full and continuous support. D o not place lifts more than 6 inches thick as measured after compaction. Compact the entire layer before placing the next layer. Do not compact by flooding if using foundation backfill with a dense-g raded base gradation.
the pipe conforms to 608.2.2.2 ; the contractor need not excavate, backfill, or shape the bed under the pipe.
1/2 inch per foot of proposed em bankment above the top of the p ipe, but not less than 6 inches. Construct the foundati on and backfill to 12 inches above the pi pe with foundation backfill as specified above.
Excavate unsuitable material a s the engineer directs and backfi ll with foundation backfill. 608.3.3 Laying Pipe
lay the pipe so the spigot or t ongue ends point in the directio n of flow.
pipe and the spigot or tongue end s before lowering pipes into t renches.
a firm bearing beneath the entire length of each section and ma ke it substantially true to the line and grade required.
adjusted and not overly large. F it and match the pipes so that if set firmly in line and grade they form a sewer with a smooth and uniform invert.
using apron endwalls, the endwall and the last 2 sections. Ties are not required on installations with masonry endwalls unless the plans show otherwise.
as the manufacturer recommends . Use full pipe sections except a s needed to meet the plan specified length. Place full pipe sections at infall or outfall ends unle ss the engineer allows otherwise. If a partial pipe section must be used at an infall or outfall end, restrain as the manufacturer recommends, or absent a recommendation, use one or more of the following: - A manufacturer supplied ex ternal mechanical coupling. - A manufactured coupling with a mastic impregnated geotextile wrap and mechanical fastening bands. - A concrete collar meeting 520.2.4 .
Effective with the December 2018 Letting 340 2019 Standard Spec ifications (8) If it is difficult to obtain the size pipe the plans or the co ntract specifies, the contractor may, with the engineer’s approval, provide a larger size.
Add 608.3.3(10) to clarify locations where pipe collars are needed.
use collars for connections to existing pipe, existing endwalls , or dissimilar pipe materials where the engineer agrees a mortar joint, m anufactured joint, coupling, o r restraint can not be used. 608.3.4 Joints 608.3.4.1 General
rubber gaskets, or engineer-approved mastic joint sealer, as sp ecified below, or by a combination of these types, unless the plans or contract special provisions sp ecify the type to use.
inside of the joint and finish smooth.
surfaces of the connecting parts of the pipe sections to form a flexible, watertight joint.
and clean dust, dirt, and other fore ign matter from them. The c ontractor may use a primer. If using a primer, use the type recommended by the preformed seal manufact urer. After the primer dries, remove the wrapper from one side of the seal only and press the seal to the primed surface. When ready to assemble, remove the re maining wrapper and fit the pip e sections in place. Shove the pipe sections together at the required alignment. Make seals of suff icient size so that after the pipe sections are in their final position a s queeze-out of the seal is eviden t around the joints exterior circumference. Remove and make flush with the interior pipe wall, any extrusion of the seal inside the pipe.
gaskets. Follow the manufacturer’s directions. 608.3.4.2 Relaid Storm Sewer
608.3.5 Backfilling Trenches
that causes no damage to the pipe. Fill the trench simultaneously on both sides of the sewer without causing injurious side pressures.
than 8 inches thick after com paction. Mechanically compact the entire length of each layer to the same degree as the material next to t he trench before placing the ne xt layer.
perform the first flooding until after backfilling the trench o r excavation to at least 2 feet above the top of the pipe, and after compacti ng the backfill by tamping. Perform the second flooding after the previous trench filling and after compacting in uniform layers. Avoid excess water to minimize pressure on the pipe. Do not puddle or fl ood if using 3/4-inch or 1 1/4- inch dense-graded base.
feet or more cover, including backfill depth, above the pipe to prevent damage under construction loads. Maintain this cushion during subsequent operations. Do n ot walk, travel across, or work near completed pipe until minimu m cover is established. 608.3.6 Clean Out
acceptance, test all installations with water or other engineer -approved methods. These tests must indicate unimpeded flow.
operations. 608.3.7 Deflection Testing
approved mandrel. Test pipe as the engineer directs after installation but before paving or finish grading.
Effective with the December 2018 Letting 341 2019 Standard Spec ifications (2) Provide a mandrel with a diameter equal to 92.5 percent of the pipe's nominal diameter and having cable attachment points on eac h end of the core. Ensure that th e mandrel has nine fins or legs permanently marked to designate the pipe size and the allowable percent deflection.
must pass through the entire section in one pass when pulled by hand without using excessive force. If the designated length of pipe fails, engineer may require addit ional testing.
608.3.8 Restoring the Work Site
or sidewalk, and perform other r elated work as the engineer dir ects.
608.4Measurement
608.4.1 Pipe Sewers
linear foot acceptably completed . This measurement equals the d istance along the centerline of the pipe, from the pipe end at a free outlet to the center of the e nd catch basin, manhole, inlet, junction or other drainage structure; or fr om center to center of catch bas ins, end manholes, inlets, other drainage structures or junctions. The department will make no deduction from these measured lengths for intermediate catch basins, manholes, inlets, other drainage str uctures, junctions, or fittings. 608.4.2 Rock Excavation for Storm Sewer
The department will measure this w ork in its original position and compute the volume, excluding boulders, by the method of average end areas.
stone greater than one cubic yard in 205.4.1 .
to an elevation 6 inches below the bottom of the pipe, whicheve r is higher. The department will measure this work horizontally a s the outside diameter of the p ipe plus 3 feet, 1 1/2 feet on either side, regardless of actual width required under 608.3.1.1 .
608.5Payment 608.5.1 General
items: ITEM NUMBER DESCRIPTION UNIT
608.0005 Storm Sewer Rock Excavation CY
608.0100 - 0199 Relaid Storm Sewer (size) LF
608.0200 - 0599 Storm Sewer Pipe Reinforced Concrete (class) (s ize) LF
608.2300 - 2499 Storm Sewer Pipe Reinforced Concrete Horizontal Elliptical (class) (size) LF
608.3000 - 3099 Storm Sewer Pipe Class III-A (size) LF
608.3600 - 3699 Storm Sewer Pipe Class III-B (size) LF
608.6000 - 6099 Storm Sewer Pipe Composite (size) LF
contract contains the Water bid item, the department will pays eparately for water under 624.5 .
608.3.2(6) as extra work. 608.5.2 Pipe for Storm Sewer Add 608.5.2(1) to clarify payment for connections including concrete collars.
concrete collars not required under 520.3.1(5) or 608.3.3(10) ; for excavating, except for rock excavation; for providing and removing sheeting and shoring; fo r constructing the foundation and backfilling; for cleaning out; and fo r restoring the work site. 608.5.3 Rock Excavation for Storm Sewer
the contract does not contain the Storm Sewer Rock Excavation b id item, the department will pay for the required excavation as s pecified for extra work in 109.4 .
Effective with the December 2018 Letting 342 2019 Standard Spec ifications 608.5.4 Relaid Storm Sewer
for excavating, removing, and ba ckfilling existing storm sewer; for replacing pipe made unusable by contractor operations; for exca vating new trench, except for ro ck excavation; for providing and removing sheeting and shoring; for constructing the foundation and backfilling; for cleaning out; and for restoring the work site.
Effective with the December 2018 Letting 343 2019 Standard Spec ifications Section 611 Catch Basins, Manholes, and Inlets
611.1Description
structures, made of concrete, brick masonry, or concrete brick or block masonry, with necessary reinforcement, metal frames, grates and lids, including require d excavating and backfilling.
611.2Materials
Mortar ........................................................ ............................................................................................... 519.2.3 Structural steel .............................................. ............................................................................................ 506.2.2 Miscellaneous metals .......................................... ..................................................................................... 506.2.3 Trench backfill ............................................... .............................................................................................. 608.2
501 as modified in 716. Provide QMP for class III ancillary concrete as specified in 716.
and rectangular structures. Manuf acture in a plant listed under precast concrete fabricators on the department's APL. Conform to the specified AASHTO materials requirements for th e structure specified except as follows: - Use concrete with 565 pounds or more cementitio us material pe r cubic yard. - The contractor may use cement conforming to 501.2.1 or may substitute for portl and cement a t the time of batching conforming to 501.2.6 for fly ash, 501.2.7 for slag, or 501.2.8 for other pozzolans. In either case the maximum total supplementary cementitious content is limited to 30 percent of the to tal cementitious content by weight. - For wet cast use air-entrained concrete with 7.0 percent +/- 1.5 percent air content.
611.3Construction
611.3.1 General
not backfill concrete brick or bl ock masonry, bri ck masonry, or precast concrete set on mortar beds until at least 3 days after completing the unit.
subject to revisions necessary to fit field conditions. The eng ineer may increase o r decrease the depth of catch basins, manholes, or in lets in order to adjust their i nlet or discharge elevations.
conforming to 608.2 .
manufacturer's recommended method . Do not dry stack adjustment rings. 611.3.2 Connections
type, and class as the sewer pipe, sewers, and conduit to which connections are made and that they conform to the same pertinent requirements.
wall and extend the pipe throug h the walls and beyond the outsi de surfaces of the walls a sufficient distance to allow for connections with conduits or sewers. Care fully construct th e masonry around them to prevent leakage around their outer surfaces.
seal around entering conduits.