Effective with the December 2018 Letting 299 2019 Standard Spec ifications Section 519 Brick Masonry and Concrete Brick or Block Masonry
519.1Description
construct manholes, inlets, or other similar drainage structures, or parts thereof.
519.2Materials
519.2.1 Clay or Shale Brick
519.2.2 Concrete Brick a nd Block Masonry Units
conforming to 501 as modified in 716. Provide QMP for class III ancillary concrete as specified in 716.
batch mixer with the required pr oportions of cement and water, to produce a homogeneous concrete mixture of a quality that the br ick or block units conform to t he following requirements:
incorporating into the work if less than 28 days.
within 20 F of the outside temper ature. Maintain the units at a temperature above 32 F during the first 6 days after curing.
code, or other engineer-approved markings.
curved to the required radii. For corners use blocks with a ret urn side not less than 1/2 the length of the normal block. Curved blocks sha ll have inside an d outside surfa ces parallel.
width or multiple block widths shall at least equal the structure width the plans show.
form the structure as the plans show with inside and outside jo ints not more than 3/8 inch thick. Also, design the block so that only fu ll-length or 1/2-length units a re required to lay any one course. 519.2.3 Mortar 519.2.3.1 Cement
519.2.3.2 Sand
- Ensure that sand subjected to the mortar strength test has a tensile or compressives trength at 3 days and 7 days of not less than 85 perc ent of that developed by mortar of the same proportions and consistency, made of the same cement a nd standard Ottawa sand. - Use sand uniformly graded fr om coarse to fine conforming to t he following gradation requirements: SIEVE PERCENT PASSING BY WEIGHT No. 8 ......................................................... ............................................................... .................................. 95-100 No. 100 ....................................................... ..................................................................................... 25 maximum No. 200 ....................................................... ..................................................................................... 10 maximum 519.2.3.3 Mortar
portland cement and 50 percent mas onry cement, or a mixture of 75 percent portland cement and 25 percent hydrated lime.
mortar in an engineer-approved mi xer and mix not less than 1 1/2 minutes. If preparing hand-mixed mortar, mix the sand and cemen t thoroughly in a clean, tight mo rtar box until unifo rm in color, then add clean water in a quantity that fo rms a stiff paste. Do not use mortar mixed longer than 30 minutes or that develops its initial set.
Effective with the December 2018 Letting 300 2019 Standard Spec ifications 519.3 Construction
thick, and that cover the entires tructure area under all brick or concrete block masonry.
contain frost, except with the engineer’s written permission an d subject to the conditions the engineer requires.
on the mortar.
to shape around irregular openings.
and close mortar joints. Maint ain horizontal courses throughout the structure. Adjoining courses shall break joints by 1/2 the length o f a brick or block, if possible . Make at least one course in every 7, for double-wall construction, all heade rs. If using brick for makin g closures, make their length not less than the width of a whole brick and, if possible, make closures with whole brick as headers.
Finish joints properly as the work progresses and on exposed fa ces strike them neatly using the "weather" joint, except if a pla ster coat is required rake the joint.
masonry, in manholes, inlets, and similar drainage structures. Make this plaster coat with the same mortar used in laying the bricks or blocks and make it not less than 1/2 inch thick. Before applying a plaster coat to a brick or block surface, wet them with water a nd let the surface dry enough to bond to the plaster coat.
compound conforming to 501.2.9 to the interior and exterior surfaces. 519.4 (Vacant)
519.5Payment
masonry specified under this section. This work is incidental to the various bid items using it.
Effective with the December 2018 Letting 301 2019 Standard Spec ifications Section 520 Pipe Culverts
520.1Description
is a contractor option; providi ng and removing temporary culvert pipe; and cleaning existing culvert pipes.
520.2Materials
520.2.1 Culvert Pipe
various classes of pipe as follows: TABLE 520-1 ALLOWABLE MATERIALS FOR CULVERT PIPE
CLASS ALLOWABLE MATERIALS III Class III reinforced concrete , corrugated steel pipe of the thickness contract designates III-A Class II and Class III reinforced c oncrete, corrugated steel of the thickness the contract designates, corrugated polyethyle ne, corrugated polypropylene III-A Non-metal Class II and Class III reinforced c oncrete, corrugated polyethy lene, corrugated polypropylene III-B Class III reinforced concrete, co rrugated steel of the thickness the contract designates, corrugated polypropylene III-B Non-metal Class III reinforced concrete, corrugated polyp ropylene IV Class IV reinforced concrete, corrugated steel pipe of the t hickness contract designates V Class V reinforced concrete, co rrugated steel pipe of the thickness contract designates
Corrugated st eel pipe ......................................... ......................................................................................... 521.2 Reinforced conc rete pipe ...................................... ....................................................................................... 522.2 Corrugated polyeth ylene pipe .................................. .................................................................................... 530.2 Corrugated polypro pylene pipe ................................. ................................................................................... 530.2
suitable for the purpose intended. 520.2.2 Pipe Cattle Pass
may use either corrugated steel o r reinforced concrete. For the given materials, conform to the following: Corrugated steel pipe cattl e pass ............................. ................................................................................... 521.2 Reinforced concrete pipe cattle pass .......................... ................................................................................. 522.2 520.2.3 Apron Endwalls for Culvert Pipe
corrugated polyethylene, and corr ugated polypropylene pipe culvert installations, and use concrete apron endwalls with concrete pipe culvert installations. For th e given materials, conform to the following: Steel apron endwalls .......................................... ......................................................................................... 521.2 Concrete apron endwalls ....................................... ...................................................................................... 522.2 520.2.4 Concrete Pipe Colla rs and Cattle Pass Walkways
concrete conforming to 501 as modified in 716. Provide QMP for class III ancillary concrete as specified in 716. 520.2.5 Backfill 520.2.5.1 General
- For foundation backfill. - For trench backfill not obt ained from the excavation.