SECTION 939 — Communications and Electronic Equipment

939.1General Description

Furnish, install, test, and provide warranty and training for communications and electronic equipment and materials as specified herein and shown in the Contract documents. 939.1.01 Definitions, Acronyms, and Abbreviations

A.Definitions
1.Field Cabinet, Type 1: a modification of the JC Standard ITS Cabinet Housing #2.
2.Field Cabinet, Type 2: JC Standard ITS Cabinet Housing #2.
3.Field Cabinet, Type 3: JC Standard ITS Cabinet Housing #1.
4.Field Cabinet, Type 4: JC Standard ITS Cabinet Housing #3.
5.Field Switch, Type A: Layer 2, minimum 6 copper ports and 2 SFP 1 Gbps fiber ports.
6.Field Switch, Type B: Layer 2, minimum 6 copper ports and 3 SFP 1 Gbps fiber ports.
7.Field Switch, Type C: Layer 2, minimum 1 copper port and 7 SFP 1 Gbps fiber ports.
8.Field Switch, Type D: Layer 2 or 3 upgradeable, minimum 4 copper ports and 4 dual-purpose

1 Gbps ports.

9.Field Switch, Type E: Layer 2 or 3 upgradeable, minimum 8 copper ports and 4 dual-purpose

1 Gbps ports.

10.Routing Switch, Hub, Type A: Layer 3, minimum 48 ports at 1G/10G/25 Gbps SFP+ and 6 ports at 40G/

100 Gbps QSFP28.

11.Routing Switch, Hub, Type B: Layer 3, minimum 48 ports at 10/100/1 Gbps copper and 4 ports at

1 Gbps SFP.

12.SFP Fiber Module, Type 1: LX optics for shorter distances.
13.SFP Fiber Module, Type 2: ZX optics for longer distances.
14.Security Lock: an electronic lock system that controls access to a field cabinet, and the cylinder can retrofit

existing field cabinet mechanical lock hardware.

B.Acronyms and Abbreviations

Refer to Sections 101.01 and 942.1.01.B for a list of acronyms, abbreviations, and terminology used in this section. 939.1.02 Related References

A.GDOT Standard Specifications
1.Section 631 – Dynamic Message Signs
2.Section 639 – Strain Poles for Overhead Sign and Signal Assemblies
3.Section 647 – Traffic Signal Installation
4.Section 682 – Electrical Wire, Cable, and Conduit
5.Section 694 – Weather Monitoring and Reporting System

1960

SECTION 939 — Communications and Electronic Equipment
6.Section 925 – Traffic Control Signal Equipment
7.Section 926 – Wireless Communications Equipment
8.Section 935 – Fiber Optic System
9.Section 936 – Closed Circuit Television (CCTV)
10.Section 937 – Detection Systems
11.Section 942 – ITS General Requirements
B.Referenced Documents
1.Refer to Section 942.1.02.B for a list of standards and documents referenced in this section.

939.1.03 Submittals Refer to Section 942.1.04 for submittal requirements. Requirements for communications and electronic equipment materials are specified herein.

939.2Materials

939.2.01 General

A.Comply with ISO 9001 or Six Sigma quality manufacturing requirements.
B.Provide only equipment and materials that are new and of like kind and function provided by one

manufacturer, using the same model, part number, revision, and firmware as shown and specified in the Contract documents. 939.2.02 Field Switch Requirements

A.General
1.Provide one or more of the field switch types listed in Table 1 as specified in the Contract documents.

Table 1 – Field Switch Types Type Layer Capability Ethernet Port Configuration Type A Layer 2 Minimum 8 ports total including 2 Gigabit-Ethernet SFP ports and 6 10/100Base-T/TX ports Type B Layer 2 Minimum 9 ports total including 3 Gigabit-Ethernet SFP ports and 6 10/100Base-T/TX ports Type C Layer 2 Minimum 8 ports total including 7 Gigabit-Ethernet SFP ports and 1 10/100Base-T/TX port Type D Layer 2 or Layer 3 upgradeable Minimum 8 ports total including 4 dual-purpose uplink or downlink ports that can be used for 10/100/1000BASE-T/TX ports or 100/1000 Mbps SFP ports, and 4 10/100/1000Base-T/TX ports Type E Layer 2 or Layer 3 upgradeable Minimum 12 ports total including: 4 dual-purpose uplink or downlink ports that can be used for 10/100/1000Base-T/TX ports or 100/1000 Mbps SFP ports, and 8 10/100/1000Base-T/TX ports

2.Provide field and routing switches that are compatible with the existing GDOT network by support of

features and implementation of common standards that enable switches to work together and minimize integration effort. 1961

SECTION 939 — Communications and Electronic Equipment
3.Provide field switches with the following interfaces:
a.Provide fiber ports with 1000BaseSFP slot or 100/1000BaseSFP slot.
b.Provide 10/100Base-T(X) or 10/100/1000Base-T(TX) RJ-45 ports with auto negotiation speed and capable

of being manually set to half-duplex or full-duplex.

c.Provide console port along with any adapter cables as needed and approved by the Department.
d.Provide LED indicators including power on/off and network status per port (transmit, receive, link,

and speed).

4.Provide field switch that can operate with non-blocking, store and forward, switching at full wire speed.
5.Provide field switch that supports detecting and shutting down one-way link failures using auto-negotiation.
6.Provide field switch with a minimum MTBF of 200,000 hours using Telcordia SR-332, Method 1, Case 3 or

MIL-HDBK-217F standards.

7.Provide field switch that complies with IEEE 802.3 for 10Base-T standard specifications.
8.Provide field switch that complies with IEEE 802.3u for 100Base-T(X) standard specifications.
9.Provide field switch that complies with IEEE 802.3ab for 1000Base-T(X) standard specifications.
10.Provide field switch that complies with IEEE 802.3z for 1000Base-X standard specifications.
C.Network Capabilities and Features
1.Provide field switch that supports multicast with IGMP v1/v2/v3 snooping and IGMP-filtering.
2.Provide field switch that complies with IEEE 802.3x (Flow Control) standard.
3.Provide field switch that complies with IEEE 802.1p (Class of Service or Priority Queuing) standard.
4.Provide field switch that complies with IEEE 802.1Q (VLAN tagging) standard per port.
5.Provide field switch that complies with IEEE 802.1D (Spanning Tree Protocol) and IEEE 802.1w (Rapid

Spanning Tree Protocol) standards.

6.Provide field switch that complies with IEEE 802.3ad (Link Aggregation or Port Trunk) standard for a minimum

of two groups of four ports.

D.Security
1.Provide field switch that can be configured for static MAC address access.
2.Provide field switch that can disable automatic address learning per ports; known hereinafter as Secure Port.

Secure Ports only forward statically configured MAC addresses.

3.Provide field switch that can trap and provide an alarm upon any unauthorized MAC address and shutdown.

Require administrator to manually reset the port before communications are permitted.

4.Provide field switch that complies with IEEE 802.1X Port Access Authentication.
5.Provide field switch that supports HTTP and HTTPS.
6.Provide field switch that supports SSL.

1962

SECTION 939 — Communications and Electronic Equipment
E.Network Management
1.Provide network management capabilities that are compatible with the existing GDOT network management

consisting of Cisco Prime centralized enterprise management software supporting remote management.

2.Provide field switch that is password manageable with a minimum of one read-only profile and one full

administration profile.

3.Provide field switch that fully implements SNMP v1/v2/v3.
4.Provide field switch that implements LLDP as defined in IEEE 802.1ab (Station and Media Access Control

Connectivity Discovery).

5.Provide field switch that fully implements RMON I statistics, history, alarms, and events objects.
6.Provide field switch that can mirror any port to any other port within the field switch.
7.Provide field switch that can be managed remotely by an enterprise software/program for configuration,

reporting, updates, and monitoring of alarms.

8.Provide field switch with environment monitoring capabilities.
9.Provide management capabilities via a serial maintenance/console serial port (local) and over the

network (remote).

10.Provide field switch that supports HTTP (Embedded Web Server) with SSL.
11.Provide field switch that fully implements RFC 783 (TFTP) to allow remote firmware upgrades.
F.Additional Requirements for Field Switch Types D and E
1.Provide, in the quantity specified in the Contract documents, Gigabit-Ethernet Combo ports, where each

Gigabit-Ethernet Combo port is defined as a single interface that can be used as a 10/100/1000Base-T/TX ports or 100/1000Base SFP GBIC socket.

2.Provide a card slot for a field removable SD read-write memory card (included) that can store switch operating

system modules and switch configuration modules and is addressable/manageable from the switch’s management interface and built-in memory system.

3.Provide field switch that can boot from and load configuration from the removable memory card slot or from

the built-in memory, as defined by the user.

4.Provide field switch that allows push/pull of switch operating system modules and switch configuration

settings from the GDOT network management system.

5.Provide field switch that can convert from Layer 2 to Layer 3 switch and routing protocols, as specified in

Section 939.2.03, with only a change in the switch operating system or license.

G.Mechanical and Cabling
1.Provide field switches that are capable of rack mounting and DIN rail panel mounting. Rack-mounted DIN rails

may be installed if cabinet space is available. Shelf mounting is not permitted.

2.Provide hardware and materials for mounting the field switch within the field cabinet.
3.Provide rubber dust caps or covers with insertion and removal handles that completely seal the port opening

for unused copper and SFP ports.

4.Provide field switch with a fan-less (no fan) design.

1963

SECTION 939 — Communications and Electronic Equipment
H.Electrical
1.Provide field switch that is capable of operating over minimum input voltage range of 108 VAC to 132 VAC at

50/60 Hz (±5%, maximum).

2.Provide field switch with power conversion as specified herein and provide regulation necessary to support

electronics operation.

3.Provide field switch that complies with IEC EN 61000-4-5 surge immunity for network equipment.
4.Provide power transformers with a “fastening mechanism.” No plug-in types are permitted. Corded

transformers shall be mountable with neatly secured power cords.

I.Environmental
1.Provide hardened field switch including power supply that comply with NEMA TS 2 Sections 2.1.7, 2.1.8, and

2.1.9 temperature, humidity, vibration, and shock testing requirements.

2.Comply with FCC Part 15 emission standard and FCC Public Notice 2019-01.

939.2.03 Routing Switch Requirements

A.General
1.Provide one or more of the routing switch types listed in Table 2 as specified in the Contract documents.

Table 2 – Routing Switch Types Type Layer Capability Ethernet Port Configuration Type A Layer 3 Providing a minimum 48 1/10/25 Gbps SFP+ ports + 6 40/100 Gbps QSFP28 uplink ports per switch Type B Layer 3 Providing a minimum 48 10/100/1000 Ethernet copper ports + 4 SFP 1 Gbps ports per switch, stackable

2.Provide routing switches that are compatible with the existing GDOT routing network consisting of Cisco

Nexus 93180YC-FX Layer 3 routing switch (Type A) and Cisco Catalyst 2960XR Layer 3 routing switch (Type B) that can be managed by the Department’s existing network management software.

3.Populate routing switch with optical SFPs meeting the minimum SFP requirements in Section 939.2.04 and as

required in the Contract documents.

4.Provide routing switch with a minimum MTBF of 200,000 hours using Telcordia SR-332, latest version, or

MIL-HDBK-217J standards.

5.Provide routing switches for up to 4,096 VLANs.
6.. Provide routing switch where modules are hot-swappable.
7.Provide routing switch that can be EIA 19 in (483 mm) rack mounted (one rack unit per routing switch, typical).
B.Network Standards and Protocols
1.Provide network that supports Layer 2 and 2+ protocols specified in Section 939.2.02.
2.Provide network that supports additional network Layer 3 protocols as follows:
a.IPv4 and IPv6.
b.Full implementation of IGMP v1/v2/v3.
c.TACACS Plus (+).

1964

SECTION 939 — Communications and Electronic Equipment
d.RADIUS protocol.
e.Full implementation of RIP.
f.Full support for BGP.
g.Full implementation of OSPF protocol.
h.Full implementation of GMRP.
i.Full implementation of GVRP.
j.Full implementation of PIM Sparse Mode.
k.Full implementation of VRRP.
C.Mechanical and Cabling
1.Provide routing switches that are rack mountable.
2.Provide hardware and materials for mounting within the equipment rack that are corrosion resistant.
3.Provide rubber dust caps or covers with insertion and removal handles that completely seal the port opening

for unused copper and SFP/QSFP ports.

D.Electrical
1.Provide field switch that can operate over a minimum input voltage range of 108 VAC to 132 VAC at 50/60 Hz

(±5%, maximum).

2.Provide field switch that complies with IEC EN 61000-4-5 surge immunity testing requirements.
3.Provide routing switch with dual redundant power supplies and fans, N+1 configuration, hot swappable, and

configured for 120 VAC service.

E.Environmental
1.Provide routing switch with power supply that meets following minimum ambient temperature and humidity

requirements:

a.Temperature range from +23°F through +113°F (−5°C to +45°C).
b.Relative humidity from 10% through 95%, noncondensing.
c.Comply with NEMA TS 2 Sections 2.1.8 and 2.1.9 vibration and shock testing requirements.
2.Comply with FCC Part 15 emission standard and FCC Public Notice 2019-01.

1965

SECTION 939 — Communications and Electronic Equipment

939.2.04 SFP Fiber Module Requirements

A.General
1.Provide SM, dual-fiber SFPs with LC connectors.
2.Provide the following types of full duplex, SFP fiber optical modules as shown in the Contract documents or

as required:

a.Type 1: LX/LH optics for single-mode fiber that is >6.2 miles (10 km) in length (under ideal conditions).
b.Type 2: ZX optics for single-mode fiber that is >43 miles (70 km) in length (under ideal conditions).
3.Provide SFPs that comply with IEEE 802.3x, 1000Base-LX/LH and 1000Base-ZX standards.
4.Provide fiber optic patch cords as specified in Section 935.2.01.G with integral optical attenuators if required

for optical power control per the field switch manufacturer’s recommendations.

5.Provide SFPs that are 100% compatible with the field switch or network device in which the SFP is inserted,

including any serial number or other identifying information. Only demonstrated proven SFPs that do not

require non-default, switch configuration settings are permitted.

6.Provide SFPs that are hot-swappable.
7.Provide SFP that operates as its own switched port.
8.Provide a quantity of fiber optic patch cords that matches the number of populated SFP ports on the field

switch, in accordance with Section 935.2.01.G, with ST connectors on one end (at the FPP/FDU) and an LC

connector on the other end (at the field switch).

B.Environmental

Provide SFPs with extended temperature capabilities meeting the following minimum requirements:

1.Ambient temperature range from +23°F through +185°F (−5°C through +85°C).
2.Relative humidity from 10% through 95%, non-condensing.

939.2.05 Network Patch Cord Requirements

C.General
1.Provide field switch patch cords that meet ANSI/TIA requirements for Category 6, four-pair unshielded twisted

pair cabling with stranded conductors and RJ-45 connectors.

2.Provide network patch cords that are factory assembled, connectorized, and certified by the manufacturer to

meet the performance standards specified herein.

3.Provide network patch cords that comply with TIA-568-C.2 and UL 444 standards.
4.Provide network patch cords with eight (four STP) insulated No. 22 to No. 24 AWG, solid bare copper

conductors arranged in four color-coded twisted-pairs.

5.Provide network patch cords with modular RJ-45 male connectors with eight-position non-keyed and eight

gold anodized pins.

6.Provide network patch cord connectors that incorporate mechanical cable strain relief and protective boots.
7.Provide network patch cords that characterize to 600 MHz and design margin (headroom) beyond standard

Near-End Crosstalk, Power Sum NEXT, Attenuation-to-Crosswalk Ratio, and Power Sum ACR. 1966

SECTION 939 — Communications and Electronic Equipment
8.Provide network patch cords with lengths of patching from field switch to equipment inside the field cabinet or

equipment rack without strain. Provide custom or standard lengths as required or needed based on final

equipment layout and configuration that permits future movement of equipment within the field cabinet or

equipment rack.

9.Provide network patch cord that is riser-rated.

939.2.06 Field Cabinet Requirements

A.General
1.Provide one or more of the field cabinet types listed in Table 3 as specified in the Contract documents.

Table 3 – Field Cabinet Types and Configuration

GDOT

Type

Joint Committee ITS

Cabinet Standard

Minimum Cabinet Dimension Range Number of

Doors

Height Width Depth

Type 1 Modified ITS Cabinet

Housing #2

30 in. to 36 in.

(0.76 m to 0.91 m)

23 in. to 26 in.

(0.58 m to 0.66 m)

18 in. to 24 in.

(0.46 m to 0.61 m)

Type 2 ITS Cabinet Housing #2 44 in. to 47 in.

(1.12 m to 1.20 m)

23 in. to 26 in.

(0.58 m to 0.66 m)

18 in. to 24 in.

0.46 m to 0.61 m)

Type 3 ITS Cabinet Housing #1 64 in. to 67 in.

(1.62 m to 1.70 m)

23 in. to 26 in.

(0.58 m to 0.66 m)

24 in. to 30 in.

(0.61 m to 0.76 m)

Type 4 ITS Cabinet Housing #3 64 in. to 67 in.

(1.62 m to 1.70 m)

44 in. to 46 in.

(1.12 m to 1.17 m)

24 in. to 30 in.

(0.61 m to 0.76 m)

2.Unless otherwise specified in the Contract documents or directed and approved by the Department, construct

all ITS cabinet (field cabinet) housing assemblies in conformance with this section and the JC ITS Cabinet

Standard Specifications for Roadside Cabinets. Do not include with the field cabinet housing the following:

a.Police panel and associated wiring.
b.Power distribution assembly and associated flasher units, and signal power contactor.
c.DC power distribution assembly (12 VDC and 24 VDC).
d.Input file and associated sensor units, isolator units, and serial interface unit.
e.Output file and associated auxiliary monitor unit, serial interface unit, transfer relay unit, and switch

pack unit.

f.Field cabinet monitor unit assembly.
g.Serial and control bus assemblies and wiring.

1967

SECTION 939 — Communications and Electronic Equipment
3.Mount field cabinets in the following configurations:
a.Unless otherwise specified in the Contract documents, configure Type 1 and Type 2 field cabinet housing

assemblies for pole mounting and Type 3 and Type 4 field cabinet housing assemblies for ground or

base-mounting.

b.Reinforce the holes for pole mounting with metal plates of adequate size and strength welded

longitudinally across the inside depth of the field cabinet.

c.Where ground or base-mounting of field cabinets is specified, make the field cabinet bottom open and

provide an approved concrete pad for mounting the field cabinet along with technician pad in front and

back of cabinet doors and base mounting adapter, in accordance with Section 647 and the standard

detail drawings.

B.Field Cabinet Components
1.Equip all field cabinet housings with the standard EIA 19 in (483 mm) rack cage as described in the JC ITS

Cabinet Standard Specifications and as follows:

a.Do not use unistruts or other rail types.
b.For Types 1, 2 and 3, equip field cabinet housings with the standard EIA 19 in. (483 mm) rack cage.
c.For Type 4, equip field cabinet housings with two standard EIA 19 in. (483 mm) rack cages.
2.Provide field cabinet with side mounting panel meeting the following requirements:
a.Fabricate side mounting panels as described in the JC ITS Cabinet Standard Specifications for J Panels.
b.Do not provide pre-punched terminal block/bar or component mounting holes, except holes for mounting

the side panel to the rack cage.

c.In all field cabinet types provide one side panel on one side of each rack cage that are the full depth of the

rack cage and the rack cage height less 2 in (50 mm) at the top and bottom.

3.Provide field cabinet with cabinet shelf meeting the following requirements:
a.Provide perforated and ventilated shelf meeting the following minimum requirements:
i.Telescoping guides to allow full extension from the rack cage.

ii. Construction that supports a weight of 25 lb. (11 kg) when extended.

iii. A minimum non-slip work area measuring 12 in. (304 mm) by 12 in. (304 mm).

b.For Types 2 and 3, equip field cabinet with one cabinet-sliding internal shelf.
c.For Type 4, equip field cabinet with two sliding internal shelves.
4.Provide field cabinet with document pouch meeting the following requirements:
a.Provide a plastic documentation pouch that is side-opening, resealable, opaque, and of a heavy-duty

plastic material to store the field cabinet and equipment documentation.

b.Provide a pouch that has metal or hard-plastic reinforced holes for hanging from hooks included on the

field cabinet door.

c.Provide a pouch has the size and strength to hold 200 sheets of 8.5 in. (215 mm) by 11 in.

(279 mm) paper.

d.Provide field cabinets with metal hooks welded to the inside of the front cabinet door, for hanging the

plastic documentation pouch securely when opening and closing the front cabinet door. 1968

SECTION 939 — Communications and Electronic Equipment
5.Provide field cabinet with wiring, conductors, and terminal blocks that meet the following requirements:
a.Provide component mounting DIN rail meeting the following requirements:
i.Mount all 120 VAC service entrance, power distribution, grounding, and surge protection components

on standard DIN rails mounted on recessed rack mounted panels or on rack side panels as shown in

the standard detail drawings. Devices include terminal blocks, circuit breakers, and surge protection

devices. Other components and devices that may be DIN rail mounted include network switches,

power supplies, and PoE injectors.

ii. Provide 1.38 in. (35 mm) wide by 0.3 in. (7.5 mm) high by 0.04 in (1 mm) thick standard DIN rails

perforated and cut to length for flexible mounting.

iii. Provide DIN rail that is burr free with no sharp edges or deformation from the standard profile.

iv. Provide DIN rail that complies with IEC EN 50022 (NS35), IEC EN 60715, and DIN 46277.

v.Provide nut, bolt, and start washers to mount to panel for low resistance electrical connection.

vi. Provide an anti-corrosion paste to provide a solid and long-lasting electrical connection between the

DIN rail and the mounting panel.

b.Provide terminal blocks meeting the following requirements:
i.Use terminal blocks with voltage and current ratings greater than the voltage and current ratings of

the wires that are terminated on the blocks.

ii. Terminate conductors on terminal blocks using insulated terminal lugs large enough to accommodate

the conductor to be terminated.

iii. Terminate field wiring terminal block screws using a terminal ring lug for termination when two or

more conductors are terminated.

iv. Use metallic terminal block connection hardware and components that are non-ferrous copper or

nickel/tin-plated copper alloy or equivalent.

v.Provide terminal blocks and wires that comply with the following colors:

Black – Line

White – Neutral

Green or Green/Yellow – Ground

vi. Provide a ground terminal that is the same size and pitch as the power terminals and provides

positive electrical and mechanical connection to the mounting rail.

vii. Provide terminal blocks that comply with UL 1059.

viii. Provide terminal blocks that are capable of being DIN-rail mounted.

ix. Provide the type and quantity of terminals as shown in the Contract documents.

c.Provide service entrance terminal blocks meeting the following requirements:
i.Make the terminal block for the 120 VAC field cabinet service entrance a 0.39 in. (10 mm) single level

screw type device.

ii. Provide a terminal block that accommodates No. 18 to No. 4 AWG wiring for terminating electrical

inputs and outputs. 1969

SECTION 939 — Communications and Electronic Equipment
d.Provide distribution terminal blocks meeting the following requirements:
i.Make the terminal blocks for distribution of 120 VAC and ground a 0.24 in. (6 mm) single level screw

type located on the protected side of the power service panel assembly.

ii. Provide terminal block that accommodates No. 22 to No. 6 AWG wiring and provide in colors as

specified herein.

e.Provide circuit breakers meeting the following requirements:
i.Provide enclosed, thermal magnetic molded case circuit breakers of the types, sizes, and quantities

listed in the Contract documents.

ii. Provide a design that allows for an additional three circuit breakers.

iii. Provide two-pole (2P) breakers for 120/240 VAC and single-pole (1P) for 120 VAC single-phase

operating voltages.

iv. Provide molded case circuit breakers that comply with and are listed with UL 489.

v.Provide molded case circuit breakers that comply with NEMA AB-1.

vi. Provide circuit breakers that have the amperage rating indicated on the face of the breaker or handle.

vii. Provide circuit breakers that have a quick-make, quick-break over center toggle-type mechanism and

a position between “ON” and “OFF” when tripped automatically.

viii. Provide circuit breakers that are 120 VAC rated with a minimum symmetrical interrupting short circuit

capacity of 10 kA.

ix. Use only circuit breakers that are DIN rail mounted.

f.Provide fuses meeting the following requirements:
i.Provide DIN rail-mounted switch or disconnect type fuse holders and fuses for low voltage AC and

DC circuits in the proper capacity and configured.

ii. Provide fuse with size rating labeled on the holder or on the panel adjacent to the holder.

g.Provide end brackets and spacers meeting the following requirements:
i.Provide screw-clamp end brackets for DIN rail mounting.

ii. Provide spacers or dividers between terminal blocks and other components as shown in the Contract

documents for visual separation.

iii. Provide spacers that snap on to DIN rail that are approximately 0.20 in. (5 mm) to 0.71 in. (18 mm)

thick and match the size of the terminals they separate.

h.Provide safety cover meeting the following requirements:
i.Provide safety covers on terminal blocks to prevent contact with exposed conductors or any metallic

components. This cover will provide electrical and visual separation between terminal blocks and

other rail-mounted devices.

ii. Provide safety covers that are approximately 0.08 in. (2 mm) thick and sized to match the terminal

blocks they protect or separate.

i.Provide internal wiring meeting the following requirements:
i.Provide insulated wiring that is appropriately sized between terminal blocks and attached devices.

1970

SECTION 939 — Communications and Electronic Equipment

ii. Utilize THHN-THWN, stranded, copper wiring for internal branch circuits. Wire size shall be compliant

with the NEC.

iii. Use a minimum No. 12 AWG grounding of each SPD, or larger if recommended by the SPD

manufacturer or indicated on the Contract documents.

iv. Use insulated green wire to connect the ground wire directly to the ground terminals.

v.Do not splice together different device grounding wires including surge protectors.
j.Provide GFI service outlet meeting the following requirements:
i.Provide one duplex, NEMA 15A, 5-15R, GFI duplex receptacle (convenience service outlet) with

ground-fault circuit interrupters, box, and cover plateable to be accessed after equipment is installed

within the field cabinet.

ii. Provide a UL-listed receptacle meeting Federal Specification #W-C-596.

k.Provide a ground buss bar of copper alloy material compatible with copper wire and provide at least two

positions where a No. 2 AWG stranded copper wire can be attached.

l.Provide field cabinets that comply with the NEC and grounding and bonding requirements in Section 682

and as required and recommended by the cabinet manufacturer.

6.Provide field cabinet with surge protection meeting the following SPD requirements:
a.Provide a Type 1 SPD for the field cabinet’s main AC power input on the load side of the field cabinet

circuit breaker. Other surge protection devices are covered under individual device specifications.

b.Provide SPD that is listed per UL 1449 4th edition, Open-Type 1, or latest edition. The SPD shall be listed

by NRTL.

c.Provide SPD that meets the following minimum performance requirements:
i.Posted at UL.com under certification with 20 kA I-nominal rating.

ii. Does not exceed the VPR and MCOV requirements listed in Table 4.

Table 4 – VPR and MCOV Surge Requirements

L-N L-G N-G

VPR 800V 1,500V 1,200V

MCOV 150V 150V 150V

iii. SCCR that equals or exceeds 100 kA.

iv. Maximum surge current rating (Imax) that equals or exceeds 50 kA per mode and 100 kA per phase

(sum of L-N plus L-G).

d.Provide SPD that has no leakage current to ground.
e.Provide SPD that supports bi-directional operation.
f.Include directly connected thermally protected MOVs.
g.Provide pluggable SPD modules.
h.Provide SPD that complies with IEEE C62.45, C62.41.1, and C62.41.2 rated for NEMA TS 2 temperature

and humidity requirements. 1971

SECTION 939 — Communications and Electronic Equipment
i.Provide SPD enclosure with a NEMA 4 rating.
j.Provide SPD that can be either wall/panel or DIN rail mounted.
k.Provide SPDs that are equipped with a visual indicator for each MOV and remote alarm monitoring.
l.Provide parts that are made of corrosion-resistant materials, such as plastic, stainless steel, anodized

aluminum, brass, or gold-plated metal.

7.Provide field cabinet with rack-mounted power strip meeting the following requirements:
a.Provide power strip with a maximum ampere rating of 15A, 120 VAC, 60 Hz.
b.Provide power strip with integrated surge protection meeting the following minimum requirements:
i.Listed per UL 1449 4th edition, or latest edition.

ii. Exceeds IEEE 587 Category A and B specifications.

iii. Minimum UL 1449 let-through voltage rating of less than 330V (RMS).

iv. Minimum AC suppression joule rating of 600 J.

v.AC suppression surge current rating of 20,000A.

vi. Minimum UL 1283 EMI/RFI noise filtering protection rating of 40 dB.

vii. LED status indicators.

c.Provide minimum of eight NEMA 5-15R receptacles or as specified in the Contract documents.

Provide spacing to accommodate a minimum of four plug-in power supplies without covering up

remaining outlets.

d.Mount the power strip on the rear near the top of the standard TIA-310-D rack cage. Mount the power

strip facing toward the back of the field cabinet providing a minimum spacing of 3 in. (76 mm) between

the outlet’s face and the field cabinet door when the door is closed.

e.Provide power strip that does not hinder accessibility to the back of existing electrical equipment.
8.Provide field cabinet with interior lighting meeting the following requirements:
a.Provide field cabinet with LED lights at the front and back.
b.Equip the field cabinet with a manual on/off switch for the LED lights that are connected to a door switch

that allows the lights to be powered when the field cabinet door is open.

9.Provide field cabinet with mechanical locks meeting the following requirements:
a.Equip the main field cabinet door with mechanical locks that accept No. 2 Corbin keys. Provide two sets

of keys with each field cabinet.

b.Provide door that has a lockable three-point latch mechanism and can accept a cyber lock with

3/8 in. shackle.

10.Provide field cabinet with temperature system meeting the following requirements:
a.Provide a thermostatically controlled ventilation blower fan(s) to maintain internal temperatures below the

upper operating temperature thresholds for installed equipment and components that are operating

continuously at full capacity.

b.Provide the field cabinet with the capability for the user to set temperature thresholds that automatically

activate the fan(s) to turn on or off when the internal field cabinet temperature exceeds the threshold. 1972

SECTION 939 — Communications and Electronic Equipment
11.Provide field cabinet with ventilation and air filter system meeting the following requirements:
a.Provide ventilation and air filter system that is designed so that openings prevent the entrance of dust,

insects, and other foreign matter.

b.Provide washable, removable, and reusable air filters.
c.Provide ventilation and air filter system with bottom trough to drain any accumulated moisture to the

outside of the field cabinet.

d.For Type 1, provide one 100 cubic feet (2.83 cubic meters) per minute (cfm) (minimum) 120 VAC blower

exhaust fan mounted near the top of the field cabinet.

e.For Types 2, 3 and 4, provide two 100 cfm (2.83 cubic meters per minute) (minimum) 120 VAC blower

exhaust fans mounted near the top of the field cabinet.

12.Provide field cabinet with cable and wire management system meeting the following requirements:
a.Provide vertical and horizontal cable management as shown in the Contract documents or as approved

by the Department.

b.Provide field cabinet with a cable and wire management system for AC branch, low-voltage power, and

communications/data wiring within the field cabinet.

c.Provide cable and wire management components attached to the field cabinet/rack cage with screws.

No adhesive or self-stick mounting is permitted.

d.Provide separate wire management for power and other field cabinet low-voltage and

communications wiring.

e.Type 4 cabinet only, provide a minimum of four wiring pass-through holes on the inside side-mounting

panels to permit patch cords to pass between the two cabinet sides:

i.Provide 5 in. (127 mm) pass-through holes that are outfitted with grommets for patch cord protection,

with the holes positioned with two in the cabinet front and two in the cabinet rear and aligning

horizontally between the two side panels.

ii. Provide plastic- or rubber-coated J-hooks or D-rings, minimum 1 in. (25 mm) depth and height,

on the inside rails of the rack cabinet cages, to organize patch cords passing between the two

cabinet sides.

939.2.07 Field UPS Requirements

A.General
1.Provide an industrial-grade UPS that is a double-conversion, on-line type.
2.Provide UPS that complies with UL 1778 standard.
3.Provide one or more of the field UPS types listed in Table 5.

Table 5 – UPS Types

Type Location UPS Output Power Capacity (full load)

Type 1 Field Cabinet 350W

Type 2 Field Cabinet 800W

Hub Hub Building 1900W 1973

SECTION 939 — Communications and Electronic Equipment
B.Functional Requirements
1.Provide UPS that is a buck / boost, line-interactive system.
a.The buck / boost mode of the BBS shall have a minimum range of 90 – 150 VAC.
b.Buck / boost mode shall not have a user configurable transfer set point.
c.Buck / boost mode shall regulate the system output between 100 – 130 VAC.
d.When the output of the system can no longer be maintained within that range, the UPS shall transfer to

backup mode.

2.Provide UPS output that is a pure sine wave at 120 VAC ±3% at 50/60 Hz (±0.3% maximum).
3.Provide UPS with a total harmonic distortion of <3% (resistive load).
4.Provide a minimum of four output receptacles type NEMA 5-15R.
5.Provide UPS with an external, make-before-break maintenance bypass capability.
6.Provide UPS with a minimum of 85% efficiency (AC-to-AC).
7.Provide UPS that supports a minimum transfer time of 0 ms for line fails/recovers, and 5 ms or less for UPS to

bypass and reverse.

8.Provide UPS with LCD display for monitoring unit.
9.Provide UPS with four dry contact closures.
10.Provide UPS with automatic low-battery and high temperature shutdown features.
11.Provide UPS that will return to normal operations without a manual reset.
12.Provide UPS with a maximum audible noise of <50 dBA at 3 ft. (0.9 m).
13.Provide UPS with battery bank(s) that mount on an EIA 19 in. (483 mm) rack using a maximum space of five

rack units.

C.Battery System
1.Provide maintenance-free sealed batteries that can be replaced separately from the UPS.
2.Provide batteries that are rated for extreme temperatures that have been field proven and tested.
3.Provide UPS batteries that maintain 70% of original capacity for a minimum of five years.
4.Provide a maximum battery recharge time of 20 hours to 80% of full charge.
5.Provide battery charger with a minimum of three-stage, temperature compensated charging and keeps the

batteries above a minimum depth of discharge point of 50% or as recommended by the manufacturer.

6.Provide user-replaceable and hot-swappable battery packs.
7.Provide batteries with non-conductive terminal covers.
8.Provide battery capacity to meet the following minimum runtimes:
a.For Type 1 and 2 field UPS, minimum runtime of 1 hour under full load as shown in Table 5.
b.For hub UPS only, minimum runtime of 4 hours under full load as shown in Table 5.
c.Capability to be expanded for increased runtime using additional expansion battery banks or packs.

1974

SECTION 939 — Communications and Electronic Equipment
D.Environmental

Provide a UPS system including battery bank that meets following minimum requirements:

1.For Types 1 and 2 field UPS, ambient temperature range from −4°F through +131°F (−20°C through +55°C).
2.For hub UPS, ambient temperature range from +32°F through +104°F (0°C through +40°C).
3.Relative humidity from 10% through 95%, noncondensing.
4.Comply with FCC Part 15 emission standard and FCC Public Notice 2019-01.
E.Remote Monitoring Requirements
1.Provide UPS that supports local and remote monitoring and control via Ethernet port interface.
2.Provide remote environmental sensing hardware and software integrated with SNMP minimally capable of

temperature and including generating alarms for low battery, over/under voltage, over/under frequency, and

high temperature.

3.Provide an addressable SNMP command set including, at a minimum:
a.UPS state.
b.Battery condition (voltage, sampling temperature of one battery).
c.Current AC input conditions (voltage, frequency).
d.Current AC output conditions (voltage, AC amps, frequency).
e.Diagnostic/self-test control and status.

939.2.08 Solar Power System Requirements

A.General
1.Provide solar power system that can be mounted in a permanent configuration or in a temporary portable

type configuration.

2.Provide one or more of the solar power system types listed in Table 6 as specified in the Contract documents.

Table 6 – Solar Power System Types

Type Application Location Site Output Power Capacity (full load)

Type 1 ITS Field Cabinet 350W (8,400 Whr/day)

Type 2 ITS Field Cabinet 800W (19,200 Whr/day)

Type 3 Lighting Lighting

Controller

Calculate based on the quantity, power requirements, and

maximum hours of operation of luminaires 1975

SECTION 939 — Communications and Electronic Equipment
B.System Requirements
1.Provide DC-to-DC and DC-to-AC conversion equipment, as specified herein.
2.Provide grounding that meets NEC ampacity requirements.
3.Provide system cabling that meets NEC ampacity requirements.
4.Provide over-current protection devices (OCPD) between each of the solar array, solar controller, battery

bank, inverter, and load for safety and maintenance.

5.Provide system that maintains the battery depth of discharge (DoD) between 20% and 50% to maximize

battery life using 3 days of autonomy (DoA).

6.Recharge ratio
i.ITS applications: minimum of 4 times

ii. Lighting applications: minimum of 3 times

C.Solar Panel
1.Provide high-efficiency, photovoltaic solar panel(s) made from tempered glass with an anodized aluminum

frame, sized to provide full charging of batteries within a one day full sunlight cycle while under operation

in December.

2.Provide solar panels that deliver power for the equipment at the site such that it operates using the lowest

average winter insolation values for the area in which the system is installed, accounting for system

inefficiencies.

3.Provide IP67-rated junction boxes on the backside of the panel.
4.Provide bypass diodes to minimize power drop caused by shade and provide better performance in

low-light conditions.

5.Provide a power max rating of 70% minimum at nominal operating cell temperature (NOCT).
6.Provide a 25-year degradation that has a minimum 80% efficiency rating.
D.Battery
1.Provide batteries that are individually replaceable, completely sealed, and maintenance free, requiring no

watering.

2.Provide battery capacity (amp-hours) and type that will keep field cabinet equipment operating for a minimum

of 72 hours without sunlight or charging of the batteries. Include a 20% safety factor to ensure operation in

unseasonable weather conditions and battery degradation over time.

3.Provide batteries based on the system constraints that maintain deep cycle capacity for a minimum of

five years.

4.Provide batteries with non-conductive terminal covers.
5.Provide ventilated enclosure with positive and negative air flow for the batteries.
6.Provide temperature sensors that are mounted to the side of the battery case and generally in the middle of

the battery bank. 1976

SECTION 939 — Communications and Electronic Equipment
E.Charge Controller
1.Provide a minimum 30A rated maximum power point tracker (MPPT) charge controller that charges 12, 24,

and 48V banks.

2.Provide charge controller that supports the selected battery type.
3.Provide charge controller with built-in energy LCD monitor to track and indicate the state of charge, voltage

level of the batteries, and output of the solar panels.

4.Provide charge controller that keeps the batteries above the minimum depth of discharge point of 50% or as

recommended by the battery manufacturer.

5.Provide charge controller with data logging capabilities that can be viewed over the network.
6.Provide charge controller that disconnects the equipment from the batteries at a variable percentage load

and allows the batteries to reach a higher state of charge, commonly referred to as a low voltage

disconnect feature.

F.Power Inverter
1.Provide power inverter as follows:
i.ITS application: provide a true sine wave DC to 120 VAC ±5% rated for off-grid solar application.

ii. Lighting application: 120 or 12/240 VAC.

2.Provide power inverter that meets the continuous power wattage (total load capacity) requirements of the field

cabinet equipment and components.

3.Provide power inverter with a minimum surge rating that is double the continuous power wattage calculation

to support equipment start-up power needs (peak power).

4.Provide power inverter with a power factor of 0.9 to 1.0.
5.Provide circuit breakers sized for the system and placed between the inverter and load, and between the

inverter and battery bank.

6.Provide power inverter sized for the system criteria, and with a minimum of three NEMA 5-15R, 15A

outlet receptacles.

7.Provide a power distribution panel in conjunction with the inverter.
G.Environmental

Provide solar panels, charge controller, inverter, and battery bank that meet the following minimum temperature

and humidity requirements:

1.Ambient temperature range from −4°F through +131°F (−20°C through +55°C).
2.Relative humidity from 10% through 95%, noncondensing.
3.Provide battery bank that is ventilated with fans that push and pull air within the enclosure.
4.Comply with FCC Part 15 emission standard and FCC Public Notice 2019-01.

939.2.09 Field Power Controller Requirements

A.General
1.Provide field power controller that is IP-addressable (static) and accessible over a network.
2.Provide field power controller with a 10/100 autosensing, port selectable, RJ-45 Ethernet interface.

1977

SECTION 939 — Communications and Electronic Equipment
3.Provide field power controller that can reboot and control outlet receptacles in remote locations from a web

browser.

4.Provide secure control through a user web interface, including SSL and multi-user password secure access.
5.Provide a minimum of 18 NEMA 5-15R, 15A outlet receptacles with eight switched pairs and two un-switched

receptacles.

6.Provide a user-configurable automatic ping feature that monitors and automatically cycles power on one or

more receptacles.

7.Provide a minimum surge protection using dual 3,600 J MOVs to clamp power surges and spikes.
8.Provide field power controller with configurable event data logging.
9.Provide field power controller that mounts on an EIA 19 in (483 mm) rack (maximum space of two rack units)

inside a standard field cabinet or hub building rack.

B.Environmental
1.Provide field power controller including power supply that comply with NEMA TS 2 Sections 2.1.7, 2.1.8, and

2.1.9 temperature, humidity, vibration, and shock testing requirements.

2.Comply with FCC Part 15 emission standard and FCC Public Notice 2019-01.

939.2.10 Security Lock Requirements

C.Provide security lock that meets the following requirements:
1.Provide a wireless electronic key security lock system that is compatible with the Department’s existing

programming equipment. The Department’s existing security lock system uses Cyberlock equipment.

2.Provide security lock system that controls access to specific field cabinet(s) on an individual basis.
3.Provide security lock system that has no pick-able keyway.
4.Provide cylinder that can retrofit existing field cabinet mechanical lock hardware.
5.Provide electronic key with key memory that stores access schedules and a list of locks it can open.
6.Provide cylinder and electronic key that are manufactured with a unique ID that cannot be changed

or duplicated.

7.Provide rechargeable batteries.

939.2.11 Miscellaneous Equipment Requirements

A.Fiber Optic Video Transmitter and Receiver, Type A
1.Provide fiber optic video transmitters and receivers that meet the following requirements:
a.Provide transmitter and receiver units with full-motion uncompressed video transmission or reception

capability.

b.Provide pulse frequency modulation.
c.Provide external ST compatible fiber optic connector.
d.Provide external female video 75-ohm BNC connector with gold-plated center pin.
e.Provide external indicator LED for power.
f.Provide operating wavelengths of 850 nm and 1,300 nm MM or 1,310 nm SM per project requirements.

1978

SECTION 939 — Communications and Electronic Equipment
g.Meet minimum 14 dB power budget.
h.Provide receiver dynamic range that is a minimum of 2 dB greater than the manufacturer’s specified

power budget. The transceiver shall fully maintain all operational performance characteristics throughout

the full receiver dynamic range, including a 0 dB path loss.

i.Comply with EIA/TIA RS-250C Medium Haul transmission.
j.Provide transmitter and receiver units that meet NEMA TS 2 environmental standards for power

interruption, temperature and humidity, power service transients, non-destruct transients, vibration,

and shock. Conformance with equivalent environmental standards by other entities may be submitted

for consideration.

2.Provide fiber optic video transmitters in the field cabinet assemblies that meet the additional

following requirements:

a.Provide transmitters that operate from a plug-in 120 VAC external transformer, with mounting screw,

plugged into an equipment outlet in the field cabinet.

b.Provide SM transmitter units that incorporate laser diode optical emitters.
c.Provide standalone metal enclosure capable of horizontal or vertical mounting.
d.Provide transmitter unit that operates in full compliance with the EIA/TIA RS-250C Medium Haul

transmission from 0dB optical path loss to the maximum specified optical path loss over the full

temperature range of the NEMA TS-2 environmental standard or other approved environmental standard.

e.Provide transmitter with maximum dimensions of 2.00 in. (51 mm) (H) x 5.5 in. (140 mm) (W) x 7.0 in.

(180 mm) (L).

3.Provide fiber optic video receivers in the control center or communications hub that meet the additional

following requirements:

a.Provide receivers that can be permanently rack mounted within a card cage with a self-contained rack

power supply.

b.Provide card cage as required.
B.Fiber Optic Video/Data Transmitter and Receiver, Type B
1.Provide fiber optic video/data transmitters and receivers that meet the following requirements:
a.Provide asynchronous, full duplex RS-232 communications.
b.Provide one-way full-motion uncompressed video transmission or reception.
c.Provide pulse frequency modulation.
d.Provide external ST compatible fiber optic connector.
e.Provide external female DB25, DB9 or terminal block RS-232 connector.
f.Provide external female video 75-ohm BNC connector with gold-plated center pin.
g.Provide external indicator LEDs for video and control signals.
h.Provide wave division multiplexing with operating wavelengths: 850 nm and 1,300 nm MM (minimum 13

dB power budget) or 1,310 and 1,550 nm SM (minimum 23dB power budget) per project requirements.

i.Provide receiver dynamic range that is a minimum of 2 dB greater than the manufacturer’s specified

power budget. The transceiver shall fully maintain all operational performance characteristics throughout

the full receiver dynamic range, including a 0 dB path loss. 1979

SECTION 939 — Communications and Electronic Equipment
j.Comply with EIA/TIA 250C Medium Haul video transmission.
k.Provide transmitter and receiver units that meet NEMA TS 2 environmental standards for power

interruption, temperature and humidity, power service transients, non-destruct transients, vibration, and

shock. Conformance with equivalent environmental standards by other entities may be submitted for

consideration.

2.Provide video/data transmitters in the field cabinet assemblies that meet the additional

following requirements:

a.Operate from a plug-in 120 VAC external transformer, with mounting screw, plugged in to an equipment

outlet in the field cabinet.

b.Provide SM transmitter units that incorporate laser diode optical emitters.
c.Provide standalone metal enclosure capable of horizontal or vertical mounting.
d.Provide transmitter unit that operates in full compliance with the EIA/TIA RS-250C Medium Haul

transmission from 0 dB optical path loss to the maximum specified optical path loss over the full

temperature range of the NEMA TS-2 environmental standard or other approved environmental standard.

e.Provide transmitter unit that meets NEMA TS 2 environmental standards for power interruption,

temperature and humidity, power service transients, non-destruct transients, vibration, and shock.

Conformance with equivalent environmental standards by other entities may be submitted for

consideration.

f.Provide transmitter with maximum dimensions of 2.0 in. (51 mm) (H) x 6.5 in. (165 mm) (W) x 7.2 in.

(183 mm) (L).

3.Provide video/data receivers in the control center or communications hub that meet the additional

following requirements:

a.Provide receivers that can be permanently rack mounted within a card cage with a self-contained rack

power supply.

b.Provide card cage as required.
C.Fiber Optic External Transceiver
1.Provide external transceivers that meet the following requirements:
a.Provide daisy chained, linear multi-drop configuration.
b.Provide asynchronous, full duplex RS 232 communication.
c.Provide external female ST connectors with T1, R1, T2, and R2 ports for fiber connection.
d.Provide external female DB-25, DB-9, or terminal block RS 232 connector.
e.Provide external indicator LEDs for power, transmit and receive (each channel).
f.Provide MM transceiver that operates at 1,300 nm (minimum 14 dB power budget).
g.Provide SM transceiver that operates at 1,310 nm (minimum 21 dB power budget).
h.Provide receiver dynamic range that is a minimum of 2 dB greater than the manufacturer’s specified

power budget. The transceiver shall fully maintain all operational performance characteristics throughout

the full receiver dynamic range, including a 0 dB path loss.

i.Provide anti-streaming communications.
j.Provide SM transmitter units that incorporate laser diode optical emitters.

1980

SECTION 939 — Communications and Electronic Equipment
k.Provide internal, nickel-cadmium trickle charge battery for a minimum of six-hour backup operation. The

battery shall be designed to have minimized degradation to reliability during extended periods of trickle

charge operation. Use corrosion resistant battery contacts.

l.Provide metal housing with maximum dimensions of 8 in. x 5 in. x 2 in. (203 mm x 127 mm x 51 mm). The

metal housing shall have flanged mounting brackets to allow for permanent mounting with screws.

m.Provide transceiver unit that meets NEMA TS 2 environmental standards for power interruption,

temperature and humidity, power service transients, non-destruct transients, vibration, and

shock. Conformance with equivalent environmental standards by other entities may be submitted

for consideration.

2.Do not use internal card-type units in field devices, such as traffic signal controllers, CCTV system controllers,

and CMS controllers.

3.Provide external transceivers in the control center or communications hub that meet the additional

following requirements:

a.Provide transceivers that can be permanently rack mounted within a card cage with a self-contained rack

power supply.

b.Provide card cage as required.
D.Fiber Optic External Star Transceiver
1.Provide an RS232 data optical star transceiver that meets the following requirements:
a.Provide star transceiver designed for multi-drop configuration with three optical data ports and one

electrical equipment data connection port, to be applied in a drop-and-repeat optical three-way to

“T” installation.

b.Provide star transceiver that is fully compatible and operable with the linear drop-and-repeat transceiver

specified herein.

2.Do not include internal battery for backup operation.
3.Provide transceiver unit that meets NEMA TS 2 environmental standards for power interruption, temperature

and humidity, power service transients, non-destruct transients, vibration, and shock. Conformance with

equivalent environmental standards by other entities may be submitted for consideration.

E.Serial Data Terminal Server
1.Provide multiport Serial Data Terminal Servers (terminal servers) that are compatible with the existing GDOT

Central Software serial port control system. The existing GDOT serial port control system consists of serial

data terminal servers (Digiboard PortServer) addressed with the Digiboard RealPort system interface.

2.Provide terminal servers that meet the following requirements:
a.Provide terminal servers that are compatible with the existing GDOT Central Software serial port

control system.

b.Provide IP addressable units supporting Ethernet 10/100Base-T/TX with RJ45 port.
c.Provide RS-232 serial ports with RJ-45 ports.
d.Provide management access by HTTP, telnet, and console ports, and password protected.
e.Provide SNMP read/write management of terminal server and individual serial ports.
f.Provide serial ports with individually configurable communication settings and TCP/UDP socket support.

1981

SECTION 939 — Communications and Electronic Equipment
g.Provide RS-232/422/485 selectable serial connections.
h.Provide serial ports with minimum 230 Kbps throughput with 64 Kbps buffering and data capture.
i.Provide firmware that is upgradeable by FTP/TFTP.
j.Provide upload/download of configuration settings.
k.Provide diagnostic LEDs for Ethernet connection and unit status.
l.Provide terminal server units that meet NEMA TS environmental standards for power interruption,

temperature and humidity, power service transients, non-destruct transients, vibration, and shock.

Conformance with equivalent environmental standards by other entities may be submitted for

consideration.

m.Provide terminal servers that are UL listed.
3.Provide Serial Data Terminal Server, 16 Port, that meets the following additional requirements:
a.Provide EIA 19 in. (483 mm) rack-mounted units with maximum vertical height of 1.75 in. (44.4 mm).
b.Provide 16 RS-232 ports mounted on the front of the unit.
c.Provide internal 120 VAC power supply.
4.Provide Serial Data Terminal Server, Type B, that meets the following additional requirements:
a.Provide units that have conformal-coated circuit boards.
b.Provide units that can be panel-mounted, rack-mounted, or shelf-mounted in field cabinets.
c.Provide minimum of two RS-232 ports mounted on the front of the unit.
d.Provide internal or external 120 VAC power supply.
5.Provide fiber optic patch cords that meet all requirements of Section 935.2.01.G.

939.3Construction

The construction and installation of the network and field cabinet equipment, materials, components, and

assemblies as specified shall meet the requirements in this section and the manufacturer’s installation requirements

and recommendations.

939.3.01 Construction Requirements

A.General Construction
1.Install network switches, field cabinets and components, UPS and battery systems, and solar power

components as required by the Contract documents and recommended by the manufacturer.

2.Install equipment in new or existing rack space in accordance with the equipment manufacturer’s

recommendations, including mounting, interconnection wiring and electrical service.

3.Furnish and install mounting hardware and incidental materials, including fasteners and auxiliary supporting

frames/brackets, as recommended by the manufacturer.

4.Furnish and install miscellaneous hardware, materials, wiring/cabling, configuration, and any other incidental

items necessary for fully operational components and subsystems shown in the Contract documents and

Section 942, except when specifically identified as existing or as work to be performed by the Department.

5.Coordinate access to Department buildings, hub buildings, and field cabinets for all work activities required in

these locations with the Department 10 days before access is needed. 1982

SECTION 939 — Communications and Electronic Equipment
6.Work on this Project requires system configuration and integration tasks to be performed by the Department

before some Contractor-installed items can be brought online and completely system tested. Coordinate all

work activities needing system configuration with the Department a minimum of 14 calendar days prior to

any testing.

7.Provide properly sized electrical service, including grounding and current rating, in the equipment racks for all

hardware installed. Furnish and install additional power outlet strips in new and existing equipment racks if

needed for the new equipment.

8.Coordinate with the Department to establish electrical utility service according to the NEC and as specified in

Section 682.

a.Verify with the local power service provider to ensure that the provided equipment is compatible with the

installed equipment.

b.Contractor shall be responsible for paying for electrical service as required from the time of testing up to

the issuance of the MAL by the Department at which time the service provider account shall be

transferred to the Department.

9.Comply with grounding and bonding requirements in Section 682 for field cabinet and components, and as

required and recommended by the field cabinet and equipment manufacturer(s).

10.For any equipment that is not rack mountable with “rack ears,” provide perforated shelves and secure shelf-

mounted equipment with rack mounting hardware.

11.Protect cable ends at all times with end caps. Never subject any cable to exceed its minimum bend radius as

recommended by the manufacturer.

12.Terminate ground wiring for field cabinet surge protectors to the field cabinet ground buss bar that terminates

the ground conductor to the field cabinet ground rod.

13.Dress and route grounding wires separately from all other field cabinet wiring.
14.Install grounding wires with the absolute minimum length possible between the surge protector and the

ground terminals.

15.Provide grommets, guides, and strain relief material where necessary to avoid abrasion of or excess tension

on wire and cable.

16.Neatly route, dress, and secure patch cords in the equipment racks and at both ends. Use all available cable

management devices and trays. Route patch cords only vertically on the sides of the equipment racks or

horizontally across the bottom or top of the racks; no diagonal routing is permitted. Follow manufacturer’s

recommendations including bend radius requirements during patch cord installation.

17.Store uninstalled cable according to manufacturer recommended bend radius and cable reel requirements.
18.Inspect and test cables for continuity when received, with results compared with factory pre-shipping tests. If

test results differ from factory pre-shipping tests by more than 10%, notify the supplier (or manufacturer) of

discrepancies for immediate correction.

19.Bond all rack cages in field cabinets in accordance with the approved manufacturer’s

installation specification.

20.Ground all field cabinet rack cages to the single-point ground for the site.
21.Provide grounding and lightning protection for all cable runs at the top of the ITS device support structures

and at the field cabinet entry port. 1983

SECTION 939 — Communications and Electronic Equipment
22.If the field cabinet and associated entry port is not collocated on the support structure, provide grounding and

lightning protection at the bottom of the support structure.

23.Provide equipment with readily accessible, manually re-settable or replaceable circuit protection devices

(such as circuit breakers or fuses) for equipment and power source protection.

24.Provide and size circuit breakers or fuses such that no wire, component, connector, PC board, or assembly

must be subjected to sustained current in excess of their respective design limits upon the failure of any single

circuit element or wiring.

B.Communications Subsystem
1.Install communications network equipment and materials necessary for a complete communications path

from the field site to the TMC or communications hub building as shown in the Contract documents.

2.Furnish and install mounting and interconnection materials, including but not limited to mounting panels and

rack hardware, fiber and Category-6 patch/jumper cables, surge protection, and power supply cables.

3.Mount field equipment in a manner so as to not restrict the replacement of other components in the field

cabinet housing or hub building.

C.Uninterruptible Power Supply
1.Install UPS and battery bank or pack in the field cabinet rack and hub building equipment rack.
2.Furnish and install a dedicated electrical service branch circuit from the hub building main service panel for

the UPS system.

3.Provide UPS system branch circuit that is in accordance with all recommendations of the UPS manufacturer,

including the provision of a locking plug/receptacle connection.

4.Locate the branch circuit receptacle as close as possible to the UPS mounting position to minimize the UPS

input line cord and to minimize tripping hazards.

5.Configure the electrical service inputs for network switches and other equipment to be supplied by the UPS.
6.Furnish and install line cords, power strips, and incidental materials to configure the UPS service to the

above equipment.

D.Solar Power System
1.Install and mount the solar panel(s) with mounting bracket and the field cabinet on the ITS pole or structure at

heights specified in the Contract documents or as directed by the Department.

2.The installation locations of poles and structures may require slight adjustments to maximize sun exposure

for the solar panel assembly. Obtain approval of final site location and orientation from the Department prior

to installation.

3.Install solar power system in accordance with the manufacturer’s recommended installation procedures and

the Contract documents.

4.Mount and orient the solar panel(s) to maximize sun exposure in accordance with the

manufacturer’s recommendations.

5.Mount panels at an angle to enable runoff of rain and snow.
6.Provide power from the solar power assembly to the controller cabinet by connecting to the UPS in

the cabinet.

7.Provide no exposed wires from the solar panel(s) to the battery and from the battery to the charge controller.

1984

SECTION 939 — Communications and Electronic Equipment
8.Install wires in liquid tight flexible conduit, run inside a pole, or other method approved by the Department.

The cost to furnish and install any conduit for the solar power assembly installation shall be included in the

cost of the solar power assembly.

9.Electrically ground the solar power assembly in accordance with manufacturer recommendations.
E.Patch Cables and Labeling
1.Label wiring and cabling, including entrance cables, jumper and patch cords, and power supply cables. Cable

labels shall consist of UV-protected, waterproof permanent ink printed or legibly written on self-laminating and

over-wrapping label material.

2.Apply cable labels at each end and in the center of the cable. Cable labels shall consist of permanent ink

printed or legibly written on self-laminating and over-wrapping label material.

3.Label patch cords using cable identification numbers shown in the Contract documents or provided by

the Department.

4.Apply cable labels at each end and in the center of the cable.
F.Security Lock
1.For an existing cabinet, remove existing lock cylinder and install electronic lock.
2.Provide electronic key to the Department 30 calendar days prior to the installation of field cabinet(s) that

require a security lock.

3.The Department will have 20 calendar days from the time that all keys and locks are provided to program the

keys and locks.

4.Provide one electronic key per electronic lock. All electronic keys and locks will become the property of the

Department at the end of the construction job. All keys shall be turned in to the Department’s ITS Project

Manager prior to the issuance of the MAL by the Department.

939.3.02 Equipment Configuration and Integration Requirements

Refer to Section 942.3.03 for network equipment configuration and integration requirements.

939.3.03 Testing Requirements

Refer to Section 942.3.04 for testing requirements.

939.3.04 Training Requirements

Refer to Section 942.3.05 for training requirements.

939.3.05 Warranty and Maintenance Support Services

A.Warranty Requirements
1.Provide a minimum warranty length as follows. If the manufacturer’s warranties for the components are for a

longer period, those longer period warranties shall apply.

a.Field switch: five years.
b.Routing switch: five years.
c.Surge protectors: five years.
d.UPS and battery system: three years.
e.All other equipment and materials furnished and installed as part of this section: two years.
2.Refer to Section 942.3.02 for general warranty requirements.

1985

SECTION 939 — Communications and Electronic Equipment
B.Maintenance Support Services

Refer to Section 942.3.02 for maintenance support services requirements.

939.4Measurement

The network equipment, field cabinets and components, UPS battery back-up systems, solar equipment, surge

protection, and communication cables defined herein and training that are complete, in place, accepted, and of the

kind, size, and type specified will be measured as follows:

A.Field Switch

Field switches (all types) with mounting hardware will be measured for payment by the number installed, complete,

functional, tested, and accepted. This price will be full compensation for labor, tools, materials, equipment, and

incidentals necessary to complete the work.

B.SFP Fiber Module

SFP fiber modules (all types) will be measured for payment by the number installed, complete, functional, tested,

and accepted. This price will be full compensation for labor, tools, materials, equipment, and incidentals

necessary to complete the work.

C.Routing Switch

Routing switches (all types) with mounting hardware will be measured for payment by the number installed,

complete, functional, tested, and accepted. This price will be full compensation for labor, tools, materials,

equipment, and incidentals necessary to complete the work.

D.Field Cabinet

Field cabinets will be measured for payment by the number actually installed, complete, functional, and accepted.

For each unit installed, furnish all required items, including but not limited to; identification and documentation,

cabinet shell, rack cage, cabinet lighting, electrical service, power strip, ventilation system including heater, locks,

internal wiring, cabling, and wire management, surge protection, grounding and bonding, and all other

components and materials specified herein and required for a complete field cabinet.

E.Solar Power System

Solar power system (all types) with all required components and materials as specified herein including panel

mounting hardware will be measured for payment by the number installed, complete, functional, tested and

accepted. This price will be full compensation for labor, tools, materials, equipment, and incidentals necessary to

complete the work.

F.Field UPS

Field UPS (all types) with all required components and materials as specified herein including panel mounting

hardware will be measured for payment by the number installed, complete, functional, tested and accepted.

This price will be full compensation for labor, tools, materials, equipment, and incidentals necessary to complete

the work.

G.Field Power Controller

Field Power Controller with all required components and materials as specified herein including panel mounting

hardware will be measured for payment by the number installed, complete, functional, tested and accepted.

This price will be full compensation for labor, tools, materials, equipment, and incidentals necessary to complete

the work.

H.Fiber Optic Video Transmitters and Receivers, Type A

Transmitters and receivers are measured for payment by the actual number furnished and installed. Provide all

mounting and interconnection materials, including but not limited to card cages, hardware, fiber, RS-232 or video

jumper cables, RS-232/485 converters and power supply cables at no separate cost to the Department. 1986

SECTION 939 — Communications and Electronic Equipment
I.Fiber Optic Video/Data Transmitters and Receivers, Type B

Transmitters and receivers are measured for payment by the actual number furnished and installed. Provide all

mounting and interconnection materials, including but not limited to card cages, hardware, fiber, RS-232 or video

jumper cables, RS-232/485 converters and power supply cables at no separate cost to the Department.

J.Fiber Optic External Transceivers (mode)

External drop-and-repeat transceivers and external star transceivers are measured for payment by the actual

number furnished and installed. Furnish all mounting and interconnection materials, including but not limited to

card cages, hardware, fiber and RS-232 jumper cables, RS232/485 converters, and power supply cables at no

separate cost to the Department.

K.Serial Data Terminal Server (16 Port and Type B)

Serial Data Terminal Servers (16 Port and Type B) will be measured for payment by the actual number furnished

and installed. For each unit provided, furnish any required Serial Data Terminal Servers and serial port

concentrators as specified at no separate cost to the Department.

L.Security Lock

Security lock will be measured for payment by the actual number furnished and installed. Provide lock cylinder

and electronic key along with all other components and materials required or necessary for a complete security

system. This price will be full compensation for labor, tools, materials, equipment, and incidentals necessary to

complete the work.

M.Training

Training will be measured as a lump sum for supplies, equipment, materials, handouts, travel, and subsistence

necessary to conduct the training.

939.5Payment

939.5.01 Communications and Electronic Equipment

Communications and electronic equipment of the type specified in the Contract documents will be paid for at the

Contract unit price. Payment is full compensation for furnishing and installing or delivering the communications and

electronic equipment. This price will include full compensation for labor, materials, equipment, tools, test equipment,

incidentals, installation, testing, and providing warranty necessary to complete the work as described in this section.

Payment Notes:

Submittal

Submittal requirements are included in Section 942.1.04 and will not be paid for separately. It will be considered

incidental to the communications and electronic equipment pay items.

Testing

Testing is defined in Section 942.3.04 and will not be paid for separately. It will be considered incidental to the

communications and electronic equipment pay items.

GDOT Central Software Integration

GDOT Central Software integration is included in Section 942.3.03 and will be paid for separately under the

Section 942.5 pay item. 1987

SECTION 939 — Communications and Electronic Equipment

Payment for communications and electronic equipment will be made under:

Item No. 939 Field Switch, Type ___ Per each

Item No. 939 SFP Fiber Module, Type ___ Per each

Item No. 939 Routing Switch, Hub, Type ___ Per each

Item No. 939 Field Cabinet, Type ___ Per each

Item No. 939 Security Lock Per each

Item No. 939 Solar Power System, Type ___ Per each

Item No. 939 Hub UPS Per each

Item No. 939 Field UPS, Type ___ Per each

Item No. 939 Field Power Controller Per each

The following pay items are eligible for use to maintain a legacy communication network. The pay items shall be used

only when required and approved by the Department.

Item No. 939 Fiber Optic Video Transmitter, 850, Multi Mode Per each

Item No. 939 Fiber Optic Video Transmitter, 1300, Multi Mode Per each

Item No. 939 Fiber Optic Video Transmitter, 1310, Single Mode Per each

Item No. 939 Fiber Optic Video Receiver, 850, Multi Mode Per each

Item No. 939 Fiber Optic Video Receiver, 1300, Multi Mode Per each

Item No. 939 Fiber Optic Video Receiver, 1310, Single Mode Per each

Item No. 939 Fiber Optic Video/Data Transmitter, Multi Mode Per each

Item No. 939 Fiber Optic Video/Data Transmitter, Single Mode Per each

Item No. 939 Fiber Optic Video/Data Receiver, Multi Mode Per each

Item No. 939 Fiber Optic Video/Data Receiver, Single Mode Per each

Item No. 939 Fiber Optic External Transceiver, Drop and Insert, 850, Multi Mode Per each

Item No. 939 Fiber Optic External Transceiver, Drop and Insert, 1300, Multi Mode Per each

Item No. 939 Fiber Optic External Transceiver, Drop and Insert, 1310, Single Mode Per each

Item No. 939 Fiber Optic External Star Transceiver, 850, Multi Mode Per each

Item No. 939 Fiber Optic External Star Transceiver, 1300, Multi Mode Per each

Item No. 939 Fiber Optic External Star Transceiver, 1310, Single Mode Per each

Item No. 939 Serial Data Terminal Server, 16 Port Per each

Item No. 939 Serial Data Terminal Server, Type B Per each

939.5.02 Training

Payment for training will be made under:

Item No. 939 Training Lump sum