1732FIBER-OPTIC TRANSCEIVERS

NC · 2024 Standard SpecificationsBook pages 825825View official source ↗

make, model number and software version of the OTDR used for testing. Furnish one hard copy of each of the OTDR trace results and one electronic pdf copy of all trace results along with digital photographs showing workmanship for each splice via the Department’s File Transfer System (FTS). Furnish the manufacturer’s make, model number and software version of the OTDR used for testing. 1731 -4 MEASUREMENT AND PAYMENT Interconnect Center will be measured and paid as the actual number of fiber -optic interconnect centers furnished, installed and accepted. Splice Enclosure will be measured and paid as the actual number of fiber -optic splice enclosures furnished, installed and accepted. No measurement will be made between aerial, underground, manhole or junction box installation of the fiber -optic splice enclosure. Modifying Splice Enclosure will be measured and paid as the actual number of fiber -optic splice enclosures modified and accepted. No measurement will be made between aerial, underground, manhole or junction box installation of the fiber -optic splice enclosure. No measurement will be made of splice trays, pigtails, jumpers, connector panels , testing and any corrective actions, repairs and replacements needed for exceeding maximum allowable attenuation or other defects , as these will be incidental to furnishing and i nstalling fiber -optic interconnect centers and splice enclosures and modifying splice enclosures . Payment will be made under: Pay Item Pay Unit Interconnect Center Each Splice Enclosure Each Modifying Splice Enclosure Each

FIBER -OPTIC TRANSCEIVERS -1 DESCRIPTION Furnish and install fiber -optic transceivers with all necessary hardware. -2 MATERIALS Refer to Division 10. Item Section Fiber -Optic Transceivers 1098 -13 Furnish m aterial , equipment and hardware under this section that is pre-approved on the ITS and Signals QPL available on the Department’s website. -3 CONSTRUCTION METHODS Install fiber -optic transceivers in each equipment cabinet and comply with manufacturer’s installation instr uctions. -4 MEASUREMENT AND PAYMENT Fiber -Optic Transceiver - Drop and Repeat will be measured and paid as the actual number fiber -optic drop and repeat transceivers furnis hed, installed and accepted. Fiber -Optic Transceiver - Self-Healing Ring will be measured and paid as the actual number of fiber -optic self -healing ring transceivers furnished, installed and accepted. Payment will be made under:

Source: North Carolina Standard Specifications for Roads and Structures, 2024 Edition. Pages 825825 of 857.