B
HomeLibrariesCopilotSearchProjectsBookmarks
FeedbackHelp Desk
Libraries
Building Codes
Code LibraryIBC — BuildingIRC — ResidentialIFC — FireIPC — PlumbingIMC — MechanicalIFGC — Fuel GasIECC — EnergyNEC — ElectricalModel Codes
Specifications
CSI SpecificationsDOT SpecsTransit SpecsUSACE
Standards
TransportationRailroadFire SafetyAccessibilityStructural
Tools & References
DiagramsAssembliesProductsCalculatorsChecklistsPermits
PricingLog in
General

5165 The department does not require a prime coat when specifying epoxy-mastic paint.

WY · 2021 Standard SpecificationsBook pages 00View official source ↗

Use aluminum-colored epoxy-mastic paint. 6 Protect other portions of the structure, traffic, and surrounding property from paint overspray.

Correct overspray damage at no additional cost to the department.

516.5MEASUREMENT and PAYMENT

1 The engineer will measure:

1.Paint Repair—Bridge Railing as one complete unit or by the foot [meter] of railing

painted.

2.Paint Repair—Structural Steel and Paint Repair—Steel Piling as one complete unit

or by the square foot [square meter] of surface area painted. 2 The department will pay as follows:

Pay Item

Pay Unit

Measure to the Nearest

Paint Repair— Bridge Railing Paint Repair— Steel Piling Paint Repair— Structural Steel

LS, FT [m]

LS, 0.1 ft [0.05 m]

LS, FT [0.5 m]

LS, SF [m ]

LS, 0.1 ft [0.05 m]

LS, SF [0.1 m ]

LS, 0.1 ft [0.05 m]

LS, SF [0.1 m ]

LS, SF [m ]

503

Pay to the Nearest

DIVISION 600

Miscellaneous Construction

504

Vacant

505

Vacant

506

Culverts and Storm Drains

603.1DESCRIPTION

1 This section describes the requirements for constructing or relaying culverts and storm

drains.

603.2MATERIALS

1 Provide materials in accordance with the following:

Material

Subsection

Admixtures Aggregate for Concrete Aggregate for Flowable Backfill Aluminum-Coated Pipe Aggregate for Bed Course Material Bituminous-Coated Corrugated Steel pipe Bolts, Nuts and Washers Corrugated Aluminum Alloy Culvert Pipe Corrugated Metal Units Corrugated Steel Pipe and Pipe-Arches Curing Materials Fly Ash Galvanized Coating High Density Plyethylene Pipe Pipe Joint Mortar Polymeric Precoated Galvanized Steel Pipe Polyvinyl Chloride Pipe – Smooth Wall Polyvinyl Chloride Pipe – Profile Wall Portland Cement Reinforced Concrete Pipe Reinforcing Steel Rubber Ring Gaskets Steel Mitered End Sections Water

801.4 803.2 803.16 808.5 803.10 808.5 815.6 808.6 808.7 808.5 802.1 801.2 815.14 808.18 808.14 808.5 808.20 808.21 801.1 808.1 811.1 808.15 808.16 814.1

507

Culverts and Storm Drains

Source: Wyoming Standard Specifications for Road and Bridge Construction, 2021 Edition. Pages 00 of 771.