General

5134 Provide grooves that begin and end within 2 in to 4 [50 mm to 100mm] in of expansion

WY · 2021 Standard SpecificationsBook pages 00View official source ↗

joints, contraction joints, and ends of the slab. 5 Lay out the grooving accurately before cutting begins.

mm] wide and from ⅛ in to ¼ in [3 mm to 6 mm] deep.

Provide grooves that are ⅛ in [3

6 Space grooves in a random pattern from ½ in to ⅞ in [12 mm to 19 mm] centers.

Continuously remove resulting slurry or residue immediately following grooving operations. Clean the lands and the grooves and leave the surface free of slurry residue and other deleterious material. Remove grooving residue by flushing, vacuuming, or other methods approved by the engineer.

513.5MEASUREMENT and PAYMENT

1 The engineer will measure Class A Concrete, Class B Concrete, and ClassS Concrete

as one complete unit or by the cubic yard [cubic meter]. The engineer will compute volumes from the neat lines specified. 2 The department will pay as follows:

Pay Item

Pay Unit

Class A Concrete

LS, CY [LS, m3] LS, CY [LS, m3] LS, CY [LS, m3]

Class B Concrete ClassS Concrete

Measure to the Nearest

Pay to the Nearest

LS, 0.1 ft [LS, 0.5 m]

LS, 0.1 CY [LS, 0.1 m3] LS, 0.1 CY [LS, 0.1 m3] LS, 0.1 CY [LS, 0.1 m3]

LS, 0.1 ft [LS, 0.5 m] LS, 0.1 ft [LS, 0.5 m]

486

Reinforcing Steel

514.1DESCRIPTION

1 This section describes the requirements for furnishing and placing reinforcing steel.

514.2MATERIALS

514.2.1 Reinforcing Steel 1 Provide materials in accordance with the following:

Material

Subsection

Reinforcing Steel

811.1

514.2.2 Reinforcing Steel Supports and Ties 1 When using metal supports, provide with legs curved to form a hook, with the ends

at least ⅛ in [3 mm] above the form work. Protect metal supports for uncoated reinforcing steel that are in contact with the exterior surface of the concrete by galvanizing or coating with plastic or epoxy. Ensure that coatings do not chip, crack, deform, or peel. Extend protection at least ½ in [12 mm] above the form work. Apply plastic protection by dipping; ensure a minimum thickness of 1/16 in [2 mm] at points of contact with form work. 2 Coat metal supports for epoxy-coated reinforcing steel completely with epoxy or plastic.

Use galvanized metal supports for galvanized reinforcing steel. For coated bars, provide support legs in accordance with the dimensional and coating requirements for uncoated bars. 3 Use plastic- or epoxy-coated tie wires for epoxy-coated reinforcing steel, galvanized

tie wires for galvanized reinforced steel, and stainless-steel tie wires for use with mechanical tying equipment. 514.2.3 Mechanical Reinforcing Steel Splices 1 Provide mechanical reinforcing steel splices consisting of a lap or butt splice system

capable of developing at least 125 percent of the specified yield strength for the reinforcing steel. When epoxy coating is specified, shop- or field-coat the mechanical splice and adjacent material as necessary with epoxy in accordance with Subsection 811.1, Reinforcing Steel, or seal the splice with an approved heat-shrink plastic sleeve in accordance with the sleeve manufacturer’s recommendations.

487

Reinforcing Steel

Source: Wyoming Standard Specifications for Road and Bridge Construction, 2021 Edition. Pages 00 of 771.